Question posted by robindigiammarino on September 11th, 2013

Getting Only Heat, Although Set To Ac.

What is proper wiring for this model?

Current Answers

Answer #1: Posted by KDG on September 20th, 2013 10:10 PM
This answer was accepted by the poster of the original question.
KDG

Member since:
September 20th, 2013

Points: 4,390
1,100
points
Hello, if you have a heat pump the set up may not be set correctly, I enclosed a few diagrams, the only difference in the heat pump and gas furnace are the O and B terminals which are energizing the reversing valve in the heat or cool mode, so if you have a heat pump and used B and got cooling inheat just switch to terminal O.

These diagrams should help you, the red 24 volt "hot leg" enters the thermostat on Red and is sent to the varous circuits, if you have a volt meter I can walk you through further diagnostics

Supporting Image

You can click the image below to enlarge


HVAC/R Journeyman with 37 years experience.
Answer #2: Posted by KDG on September 20th, 2013 10:10 PM
KDG

Member since:
September 20th, 2013

Points: 4,390
100
points
mistake

Supporting Image

You can click the image below to enlarge


HVAC/R Journeyman with 37 years experience.

Related Honeywell CT3595 Manual Pages

Owner's Manual - Page 1

... Reserved 69-1199-4 Set Fan Operation Switch...10 Step 7. Set the Fan and System Switches...18 If You Have a Problem ...19 Smart Response™ Technology ...21 Wiring Diagrams ...22 ® U.S. Honeywell CT3500/CT3595 PROGRAMMABLE THERMOSTAT Weekday, Saturday and Sunday Programmable Heat and/or Cool Low Voltage (20 to 30 Vac) Thermostat and Wallplate Model CT3500/CT3595 OWNER'S GUIDE Para...
Owner's Manual - Page 2

...an old control containing mercury in home comfort controls. You can use the preprogrammed schedule, or set your old control in a sealed tube, do not place your own. This manual answers many ... instructions regarding recycling and the proper disposal of energy and money by the time you wake up or return home. • Saves the maximum amount of this thermostat is replacing a control that ...
Owner's Manual - Page 3

... MODE SYSTEM SWITCH SELECTS HEAT/OFF/COOL FAN SWITCH SELECTS AUTO/ON HEAT/COOL SETTING SWITCHES BETWEEN HEAT SETPOINTS AND COOL SETPOINTS WHILE PROGRAMMING M18589 3 69-1199-4 DIGITAL DISPLAY SET CURRENT DAY/TIME SETS CURRENT TIME AND DAY RUN PROGRAM RETURNS THERMOSTAT TO NORMAL OPERATING MODE Run Program Set Current Day/Time HOLD TEMP SETS A HOLD TEMPERATURE AND ACTIVATES...
Owner's Manual - Page 4

... THE BATTERIES ARE LOW AND MUST BE REPLACED SHOWS CURRENT SYSTEM SWITCH POSITION HEAT/OFF/COOL DISPLAYS EITHER ROOM OR SET TEMPERATURES SHOWS THAT THERMOSTAT IS SHOWS SMART RESPONSE IS OFF CONVENTIONAL RECOVERY IS ON INFORMATION AND WAITING TO CALL FOR HEAT OR COOL SHOWS SMART RESPONSE IS CHANGING THE TEMPERATURE TO MEET THE...
Owner's Manual - Page 5

... No Single Stage Heat Pump Yes Multistage Heat Pumps/Multistage Equipment No a Compatible with 3-wire zone valves or 2-wire White Rodgers no. 1361 zone valves. b Millivolt system must be heating only. Table 1. System Type Compatibility with your system is compatible with CT3500/CT3595 Gas - Compatibility Chart. Package Contents • ThermostatWiring labels •...
Owner's Manual - Page 6

... your new thermostat and wallplate. q Carefully unpack your heating and cooling systems to the C or C1 clock terminals on the cover. q Remove the cover from the old thermostat. q Disconnect the wires from the old thermostat. As you may find one or two wires going to make sure they work properly. WIRES THROUGH WALL OPENING Replacing a Clock Thermostat that has...
Owner's Manual - Page 7

... wall. q Position the wallplate on these systems. For details, call your local heating and/or cooling contractor. Loosely insert mounting screws into the drilled holes until they are flush with your system. Thermostat functions properly when WALL ANCHORS (2) not level. However, some hot water (zoned) heating systems also have three wires for appearance if desired.
Owner's Manual - Page 8

...STEP 4. Refer to both acceptable, (see illustration). q Remove the factory-installed jumper connecting terminals R and RC if wires are both of your old thermostat wire with the corresponding terminal letter on the wires when you placed on your local heating/air-conditioning contractor. R q Loosen the terminal screws. FOR WRAPAROUND INSERTION STRIP 7/16 IN. (11 MM...
Owner's Manual - Page 9

Tape off end of the thermostat and the heating/cooling system. M10622 9 69-1199-4 Terminal Designations on Old Thermostat Connect To Description R, RHa, 4, V R Power Rc, Ra Rc Power for programming and operation of the wire with electrical tape and push the taped wire back into the wiring hole in heat. (Single stage heat pump only). Cc, Xc, Bb Do...
Owner's Manual - Page 10

... a low battery indicator, replace the batteries once per year to prevent leakage and to prevent the thermostat and heating/cooling system from shutting down due to lack of power. If the display is the correct setting for instructions. When the batteries are dead or installed incorrectly. As a precaution when leaving home for one...
Owner's Manual - Page 11

... oil forced air furnace. - You can damage the keyboard. CUSTOMIZE YOUR THERMOSTAT Your Honeywell thermostat comes preset to the most commonly used settings. Temperature °F. - 12-hour clock format. Sharp instruments like pens and pencil points can change any or all of these settings. FEATURE NUMBER OPTION M13330 11 69-1199-4 STEP 7. B. IMPORTANT Always...
Owner's Manual - Page 14

... you get up and while you get ready for an energy-saving temperature while you can be helpful when planning your schedule for activities before bedtime. (This is a higher temperature during the heating season and a lower temperature during the cooling season). STEP 10. Pressing displays the current temperature settings. There is located behind the thermostat...
Owner's Manual - Page 15

Period Wake Leave Return Sleep Default Setting Time (6:00AM) Heata (70°F/21°C) Coolb (78°F/25.5°C) Time (8:00AM) Heata (62&#... Time (10:00PM) Heata (62°F/16.5°C) Coolb (82°F/28°C) Weekday (Mon-Fri) Saturday (Sat) a Your heating setpoints cannot be higher than 99°F (35°C) or lower than 40°F (4.5°C). Wake q Press Day until the desired ...
Owner's Manual - Page 16

q Heat/Cool Press Settings to be cleared. q Press Day until the display shows the desired temperature setpoint. q Repeat the above steps for each period to switch between heating and cooling setpoints. ...to 37°C) for cooling. q Press and hold the , Leave Return , or Sleep for heating and cooling. q Press , Leave Return or Sleep and repeat these steps for each step in ...
Owner's Manual - Page 17

...THERMOSTAT Change Temperature Setting Until the Next Program Period (Temporary Change) q Press or until the desired number of days that you will be cancelled before the designated time, press Run Program to return to room temperature after approximately three seconds). Change Temperature Setting... (Heat or Cool). q Run To cancel "Hold" press Program . Change the Temperature Setting Until...
Owner's Manual - Page 18

... air circulation or for most homes. Heat: The thermostat controls your air conditioning system. Cool: The thermostat controls your heating system. On Fan Auto On Fan Auto Heat System Heat System Off Cool Off Cool Heat System Off Cool 69-1199-4 18 Fan Auto: Normal setting for more efficient central air cleaning. (In a heat-only system, fan runs continuously...
Owner's Manual - Page 19

Display does not appear. • • Temperature settings will not change • (example; Mount and latch the thermostat on the wallplate if it is in the On position, and set the heating higher or the cooling lower). Solution Guide. cannot set it to respond. Make sure the power switch at the equipment is in the Off...
Owner's Manual - Page 20

... cooling contractor. Then... • Make sure the cooling setpoint is below model number). • Type of heating/cooling system (for example, hot water, warm air, oil, or gas). • Location and number of this thermostat. The cooling setting range is not tripped, and reset it to www.honeywell.com/yourhome or call Honeywell Customer...
Owner's Manual - Page 21

... Operating in Energy Savings Mode Recovery Begins Mon System Heat AM Heat Sleep In Recovery Mon System Heat Room AM Heat Sleep In Recovery 1 Room 62 F Mon System Heat AM Sleep 5:00 Room 5:30 6:00 6:30 ENERGY SAVINGS PERIOD RECOVERY FROM ENERGY SAVINGS TIME COMFORT PERIOD THERMOSTAT USES THE SAME SCHEME TO RETURN TO LOWER COMFORT...
Owner's Manual - Page 22

...AND OVERLOAD PROTECTION AS REQUIRED. 1 M10618 69-1199-4 HEATING COOLING FAN RELAY OR CONTACTOR RELAY 1 VALVE COIL COIL 1 POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. WIRING DIAGRAMS 2-WIRE HEAT-ONLY (JUMPER INTACT) THERMOSTAT B RC O W Y R G 4-WIRE HEAT/COOL (JUMPER INTACT) THERMOSTAT B RC O W Y R G HEATING RELAY OR VALVE COIL 1 POWER SUPPLY.

Similar Questions

Heat And Ac Come On In Heat And Cool Mode Rth7500
My heat and ac are always on in heat and cool mode everything is programmed correctly. I have a natu...
(Posted by bhiatt82 10 years ago)
We Have Suitepro In Condo. We Switch Heat To Ac. How To Start?
We have SuitePRO in condo. we switch today from heat to AC. we pressed cool but temp going up. Anyth...
(Posted by Anonymous-59563 11 years ago)
Ask a New Question
Use the box below to post a new question about this Honeywell product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Honeywell Manuals

Find free Honeywell CT3595 manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Honeywell Reviews

View thousands of Honeywell user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Honeywell customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Honeywell customer service rankings, employee comments and much more from our sister site.

Honeywell Recalls

Find comprehensive Honeywell recall information updated hourly on RecallOwl.com.