Question posted by ray64616 on October 1st, 2012

Push Button Wiring Terminals

i installed a new sl3000ul gate opener on my existing sliding gate. i connected thr push button (dry contact) to terminals 9 and 10 according to the schematic. the gate will open with the push button but it will not close. what am i missing???

Current Answers

Answer #1: Posted by Anonymous-84040 on November 14th, 2012 11:29 AM
This answer was accepted by the poster of the original question.
Anonymous-84040

Member since:
November 14th, 2012

Points: 1,100
1,100
points
use terminals 11 and 12 only,  per the manual

Related LiftMaster SL3000UL Manual Pages

SL3000UL Manual - Page 3

... 9 Safety Catch Rollers and Gate Rail Stops 10 Mounting Operator 11 Chain Installation Types 12 Control Board Description 13 Surge Suppressor Terminal Connections 14 wiring Earth Ground Rod Installation 15 120Vac Power Connection 16 Heater Power Connection 16 Linking Master/Second Operators 17 Solenoid/Maglock Connection 18 Factory Installed DC2000™ Connection 19-20 Plug-In Loop...
SL3000UL Manual - Page 6

... access opening and closing to the installation of the gate where easily visible. 11. O ne or more contact sensors shall be located where the risk of entrapment or obstruction exists, such as at the leading edge, trailing edge and post mounted both directions prior to reduce the risk of a vehicular horizontal slide gate. Improperly designed, installed or maintained...
SL3000UL Manual - Page 9

...Wiring. CAUTIOEnNftorar pOmPeEnNt CDyacnleger ENGLISH Outside ProOpuetrstiydeLSoaofpety Safety loops allows the gate to installation of the gate rail prior to stay open and close gate... gate. • Locate entrapment protection devices to protect in your gate application. Non-Contact SensoWrsA(RPhNoItNoeGlectric Sensors) Install photoelectric sensors to protect between moving gate ...
SL3000UL Manual - Page 10

... sensor for cycle on wall. See Loop Detector Wiring. Contact SenWsoArsR(NEIdNgeGSensors) Install edge sensors to stay open when vehicles are obstructing the gate path. Edge close gate cycles. • Locate entrapment protection devices to installation of the gate rail prior to protect between moving gate and RIGID objects, such as posts or walls. WARNING SUGG E S T E D s a f et...
SL3000UL Manual - Page 12

... and gate. 1/2" 1/2" Gate Rail Stop When fully opened, the end of the sliding gate should stop or catch post in certain instances. s a f et y c at least five inches from an obstructing wall. 5" End View of Gate and Wall Note: For safety reasons, physical stops MUST be installed on both ends of the gate rail prior to installation of the gate operator...
SL3000UL Manual - Page 16

... Installed Radio Receiver Card Reader Separate power for TES. Push Button Dry Contact Telephone Entry System 12Vdc Failsafe Photoelectric Sensor NOTE: Terminals 11 and 12 are the ONLY terminals that will ONLY Open with connection. All other terminals will Open and Close with a single push of external devices: • ENSURE bare wires make good contact inside removable terminal connections...
SL3000UL Manual - Page 19

... COMMAND PROCESSED FIRE DEPT. exit Fire Dept Strike Open Loop Key Switch push Button + radio receiver Class 2 Supply 24 Volts DC CHASSIS GROUND Shield Wire Connect Master M/S Link G to Second M/S Link B. Connect Master M/S Link B to Second M/S Link G. Example: There is a double gate, the entry gate is to entry gate only. 2. Plug-in same conduit. Master Board Master/Second control...
SL3000UL Manual - Page 21

...; is set the same as "One-Button", "Three Push Button", "Key Switch", "Photoelectric Sensor" or "Edge Sensor" will be controlled by separate devices wired to operate gate. Normal operation will cancel the automatic mode of the DC2000™. Typical Auto Mode Example: If the DC2000 is "automatically opening" the gate due to it can be dedicated to...
SL3000UL Manual - Page 22

... should be dry-contact which do not consume any reason. Manual One-Button 1234567 See Accessories 1234567 Reset button and interlock wires, Do Not Remove. The entrapment protection devices connected to maintain gate safety when the DC2000™ is for more information on correct Fire/Police emergency key access. Turn key again and HOLD to Open. DO NOT...
SL3000UL Manual - Page 24

... durable loop). exit Fire Dept Strike Open Loop Key Switch push Button + radio receiver Class 2 Supply 24 Volts DC ProIpnesritdye See Accessories 120Vac "Safety" Loop Detector - Road Surface Sealant Backer Rod Min 1" Recommended Loop Wire XLPE 12-18 gauge (Use heavier wire gauge for a more information about loop detectors. Allows gate to the detector • Have...
SL3000UL Manual - Page 27

... information. n.c. Ground Ground Ba Second Operator 3 Button Station Dry Contact Proximity Switch 12Vdc House Alarm CENTER SAFETY EXIT Stop Button Dry Contact NOTE: Cut jumper W4 wire ONLY when installing a 3 button station, stop button, or QCC. QCC A B OPEN STOP CLOSE MAGLOCK ALARM ARMED M/S LINK W4 Quick Close Circuit Allows the gate's close quicker than the OmniControl™...
SL3000UL Manual - Page 29

... death from High to open or close for 1/4 second regardless of the length of any type remote in HIGH security mode. PAWRDEAVCREANRUITNCEIGNÓCNIA With the jumper in the (M) momentary position, the contacts will stay closed . ENGLISH CDeAfauUlt PTosiItioOn N P4 P2 ENGLISH HIGNHORAM DVEHIRGNHOTREMNCIA Changing security from a moving gate or door. To verify, refer...
SL3000UL Manual - Page 30

..., and (2) this receiver and/or transmitter are now erased. NOTE: Receiver wiring on the receiver. Disconnect the second receiver when using a master/second setup. See Accessories ...the push button on the hand-held remote NOT included. NOTICE: To comply with FCC Standards FOR HOME OR OFFICE USE. Press and release the "Learn " button on Surge Suppressor Terminal Connections page...
SL3000UL Manual - Page 38

... Brown Com Motor Red Purple Com Blue N.O. Dry - - - 24Vdc 0Vdc 5 or 0Vdc 0V 5 or 0Vdc 0Vdc 0Vdc 2 to 10Vdc 2 to 10Vdc 2 to 10Vdc 2 to 10Vdc Master/Second Link Input Radio Receiver, Strike Open Push Button, Fire Dept Key Switch Inputs External Loop Detector Center, Safety, Exit Wires Input Note: See diagram on previous page. Reset...
SL3000UL Manual - Page 44

... by separate devices wired to the OmniControl™ board and surge suppressor. Reset Switch Common Radio - Radio Relay Reset Switch/Interlock Assembly One Button Key Switch Radio Relay Radio + 12Vdc Photoelectric Sensor + 12Vdc Direction Out Out Out Out Out Out Level (+/- 10%) 5 or 0Vdc Input Connection 5 or 0Vdc • Manual Three Button (Dry) 5 or 0Vdc Reset...
SL3000UL Manual - Page 50

...GARAGE DOOR OR GARAGE DOOR HARDWARE, INCLUDING BUT NOT LIMITED TO THE DOOR SPRINGS, DOOR ROLLERS, DOOR ALIGNMENT OR HINGES. UNDER NO CIRCUMSTANCES SHALL SELLER BE LIABLE FOR CONSEQUENTIAL, INCIDENTAL OR SPECIAL DAMAGES ARISING IN CONNECTION... the instructions regarding installation, operation, maintenance...comply strictly with new or factory-...SL3000UL™], AND NO IMPLIED WARRANTIES WILL EXIST...
SL3000UL ADDENDUM Manual - Page 3

DO NOT push the gate from the SL3000UL™ series. • SAVE THESE INSTRUCTIONS. Addendum Page 2 Pickets Manually Backdrive Gate Push FIRMLY from end of gate to understand how the features of SEVERE INJURY or DEATH: • READ AND FOLLOW ALL INSTRUCTIONS. • This operator is intended for installation ONLY on gates used for correct procedure. IMPORTANT SAFETY INSTRUCTIONS...
SL3000UL ADDENDUM Manual - Page 6

Exit Fire Dept Strike Open Loop Key Switch Push Button + Radio Receiver Class 2 Supply 24 Volts DC 8 7 Knox Box ACFICREESS OPprtioodnuaclt Dry Contact Switch ACFCIREESS Part # FB120 Gate will bend! Gate MUST be manually backdriven to manually open with security key switch. DO NOT push the gate from end of AC Power Failure for more information. IMPORTANT The Emergency Key ...
SL3000UL ADDENDUM Manual - Page 7

... Module Part # K74-50276 Relay Contact Rating 2 Amp - 125 AC/DC 2 Amp switching load capability Addendum to Page 26 in the SL3000UL™ Manual Addendum Page 6 STRIKE OPEN RADIO RECEIVER GATE LOCKED EXIT LOOP SAFETY LOOP CENTER LOOP RESET MOTOR CLOSE STOP OPEN POWER OVERLOAD MADE IN USA 2 1 J3 4 3 6 5 8 7 10 9 DO NOT connect a Solenoid or Magnetic Lock...
SL3000UL ADDENDUM Manual - Page 8

... in the SL3000UL™ Manual Optional External Loop Detector Wiring GBA ® OmniControl Surge Suppressor P/N Q410 Patent Pending 123456 7 8 9 10 11 12 13 G BA M/S Link Center Loop Safety Loop - External 110 Vac "Exit" Loop Detector - Allows gate to stay open for 4 vehicles 14 feet or longer. Exit Fire Dept Strike Open Loop Key Switch Push Button + Radio Receiver...

Similar Questions

Ask a New Question
Use the box below to post a new question about this LiftMaster product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

LiftMaster Manuals

Find free LiftMaster SL3000UL manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

LiftMaster Reviews

View thousands of LiftMaster user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete LiftMaster customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed LiftMaster customer service rankings, employee comments and much more from our sister site.