Get support for Maytag MEDB850WQ - Bravos 7.3 cu. Ft. Electric Dryer

Maytag MEDB850WQ Support Question

Maytag MEDB850WQ Support Question

Find answers below for this question about Maytag MEDB850WQ - Bravos 7.3 cu. Ft. Electric Dryer.
Need a Maytag MEDB850WQ manual? We have 4 online manuals for this item!
Question posted by denncans7 on April 30th, 2013

Dryer Belt Replacement

How to replace a dryer belt on the electric dryer?

Current Answers

There are currently no answers that have been posted for this question.
Be the first to post an answer!

Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.

Related Maytag MEDB850WQ Manual Pages

Owners Manual - Page 2

...." This symbol alerts you to reduce the chance of others . All safety messages will tell you what can happen if the instructions are very important. DRYER SAFETY Your safety and the safety of injury, and tell you what the potential hazard is the safety alert symbol. All safety messages will follow...
Owners Manual - Page 10

...As needed . Wet both the dryer and fabrics. ■ If lint falls off screen with your load is hard to complete drying, if needed cleaning Laundry detergent and fabric softener residue can..., or more frequently, if it becomes clogged due to remove residue buildup. 4. Replace screen in the door opening of the dryer. A screen blocked by lint can build up . Clean the lint screen with ...
Owners Manual - Page 11

... the water inlet hose from faucet and drain. Make sure leveling legs are secure in death or electrical shock. 1. Periodically inspect and replace inlet hoses if bulges, kinks, cuts, wear, or leaks are away. When replacing your dryer during freezing weather, winterize it will not freeze. Tumble a load of clothes. If storing or moving...
Owners Manual - Page 12

... side? In the U.S.A. - Confirm the power cord is crushed or kinked. If the message persists, have heat. Replace the bulb with the screw. 4. Check that both fuses are using. Electric dryers require 240-volt power supply. Replace the fuse or reset the circuit breaker. Confirm your vent system falls within the recommended run cleaned...
Owners Manual - Page 13

...certain environmental or installation conditions, you do so can result in back or other clothing. Level the dryer. Stains on load ■ Is the lint screen clogged? Check that can result in a ...from loads consisting of lint or replace exhaust vent with water and heat to other injury. ■ Is the automatic cycle ending early? For Steam Dryers select Custom Refresh cycle to ...
Owners Manual - Page 14

...state to state or province to you. MAYTAG® LAUNDRY WARRANTY LIMITED WARRANTY For one year from the date ...HEREIN. You can be provided by Maytag. 5. The new electric heating element may not apply to province. Service calls to ...designated service company. Replacement parts or repair labor if this major appliance is connected to both the faucet and dryer's water inlet valve....
Warranty Information - Page 1

Check that existed when this major appliance was purchased. MAYTAG® LAUNDRY WARRANTY LIMITED WARRANTY For one year from the date of products not .../serial numbers that water inlet hose is connected to both the faucet and dryer's water inlet valve. Replacement parts or repair labor on major appliances with electrical or plumbing codes, or use of purchase, when this major appliance is...
Dimension Guide - Page 2

...electrical supply, if specified on the serial/rating plate) on a separate 30-amp circuit, fused on both sides of the exhaust. Connect to the chart. Maytag Vent System Chart Number of 90° elbows Type of vent Box/louvered hoods Angled hoods 0 Rigid metal 100 ft. (30.5 m) 94 ft. (28.7 m) 1 Rigid metal 90 ft...add one 90º turn inside the dryer. Determine vent path: ■■ ...
Installation Guide - Page 4

... side of automatic sensor cycles, resulting in door are provided. See "Venting Requirements." 4 If using power supply cord, a grounded electrical outlet located within 4 ft. (1.2 m) of the water fill valves, and water pressure of dryer to reduce noise transfer. Check code requirements. For each arrangement, consider allowing more space for walls, doors, and floor...
Installation Guide - Page 5

...SRDT and be at least twice as large as a nearby window) should be at least 4 ft. (1.22 m) long. A copy of the above code standards can be obtained from your "Use... homes to the neutral conductor (white wire) within the dryer. Electrical Connection To properly install your responsibility: ■■ To contact a qualified electrical installer. ■■ To be sure that the ground...
Installation Guide - Page 6

... identified by direct wire: Power supply cable must be insulated. ■■ 10-gauge solid copper wire (do not use aluminum) at least 5 ft. (1.52 m) long. Prepare dryer for electrical connection and to its feet. To avoid damaging floor, use a wrench to finish turning legs until it is no longer visible. Now stand...
Installation Guide - Page 10

...(25 mm). Connect ground wire A Direct wire cable must have a tight fit with the dryer cabinet and be moved if needed. Connect ground wire (green or bare) (F) of wires into hooks. The strain... relief should have 5 ft. (1.52 m) of cable, leaving bare ground wire at 5" (127 mm). Prepare your wiring looks like...
Installation Guide - Page 11

...back 1" (25 mm). Remove center screw Optional 3-wire Connection You must have 5 ft. (1.52 m) of cable. Finally, reinsert tab of terminal block cover into slot of... facing right). Prepare to neutral wire. 1. Remove neutral ground wire (E) from end of extra length so dryer may be moved if needed. Secure cover with outer covering. Remove center terminal block screw (B). Squeeze hooked ...
Installation Guide - Page 12

... and supported in enclosed walls, ceilings, or floors. ■■ The total length should not exceed 7 3/4 ft. (2.4 m). Flexible metal vent: (Acceptable only if accessible to avoid sagging and kinking that may be used . ... any gas vent, chimney, wall, ceiling, attic, crawlspace, or a concealed space of dryer rear panel. Replace plastic or metal foil vents with hold-down screw.
Installation Guide - Page 14

...you prefer, dryer may be ...dryer. ■■ Reduce performance, resulting in Vent System Chart. Refer to determine type of vent Box/louvered hoods Angled hoods 0 Rigid metal 64 ft. (20 m) 58 ft. (17.7 m) 1 Rigid metal 54 ft. (16.5 m) 48 ft. (14.6 m) 2 Rigid metal 44 ft. (13.4 m) 38 ft. (11.6 m) 3 Rigid metal 35 ft. (10.7 m) 29 ft. (8.8 m) 4 Rigid metal 27 ft. (8.2 m) 21 ft...
Installation Guide - Page 15

... 1. Turn cold water off, remove and replace rubber washer Turn cold water faucet off and...ft. (30.5 m) 94 ft. (28.7 m) 1 Rigid metal 90 ft. (27.4 m) 84 ft. (25.6 m) 2 Rigid metal 80 ft. (24.4 m) 74 ft. (22.6 m) 3 Rigid metal 71 ft. (21.6 m) 65 ft. (19.8 m) 4 Rigid metal 63 ft. (19.2 m) 57 ft. (17.4 m) NOTE: Bottom exhaust installations have a 90° turn to the charts. The dryer...
Installation Guide - Page 17

.... See "Level Dryer". q Check for certain part replacement or repair. Do not select Air Only Temperature setting. This dryer automatically runs an installation...dryer. See "Troubleshooting". q If you receive an L2 code, there may be crushed or blocked. q Read "Dryer Use" in the dryer. q For power supply cord installation, plug into an outlet and/or electrical...
Installation Guide - Page 18

... 1. Remove remaining two loose screws from the dryer door opening . 2. Remove the door strike from dryer front panel. 5. Remove the 4 plastic plugs located outside the dryer door opening . 2. Remove the cosmetic screw opposite the door strike. Lay the door on the door. Remove the door assembly A B 1. Replace the 4 screws in the same holes 3. Remove...
Installation Guide - Page 19

.... The drum may not have not tripped. If the problem continues, call an electrician. ■■ Is the correct power supply available? Electric dryers use two household fuses or circuit breakers.Replace the fuse or reset the circuit breaker. If the message persists, consult a qualified electrician. ■■ "AF" (low airflow condition): The...
Installation Guide - Page 20

... of dryer cycles requires temperatures above 45°F (7°C). Run the dryer for most installations, the rear of the door. If you do not feel air movement, clean exhaust system of lint or replace exhaust ... and use it only once. ■■ Is the exhaust vent the correct length? DRYER RESULTS Clothes are not drying satisfactorily, drying times are too long, or load is not too...

Maytag Knowledge Base Results

We have determined that the information below may contain an answer to this question. If you find an answer, please remember to return to this page and add it here using the "I KNOW THE ANSWER!" button above. It's that easy to earn points!

  • Dryer does not heat - Electric dryer
    ...nbsp;can be found on the dryer? The drum may not have heat. Has a household fuse blown or has a circuit breaker tripped? Replace the fuses or reset the circuit ... Gas dryer FAQs Knowledgebase search tips My dryer will not start Damp loads or long drying times - Electric dryers use 2 household fuses or circuit breakers. If the problem continues, call an electrician. Dryer Did you...
  • Display shows L2 - Dryer
    ... your dryer. Electric dryers use two household fuses or circuit breakers. The power supply cord may not have heat? Is the dryer drum not turning, or is tumbling. If the dryer drum... Dry heated cycle, and restart the dryer. If the problem continues, call an electrician. Dryer does not heat - Press any key to schedule service. Replace the fuse(s) or reset the circuit ...
  • Surface burners fail to ignite
    ...nbsp;be checked by blowing cool air on . Do not clean in the search tool below. Replace the burner cap, making sure the alignment pins are set on burners while wet. If there ... clogged, refer to gas, have verified gas is turned on the area using a hair blow dryer. My gas oven won't operate Product Recall Information Normal gas range sounds Proposition 65 Warnings Cleaning tips...

Similar Questions

Dryer Is Heating But Not Drying Clothes Completely
The dryer is heating but nor drying clothes well. Lint is collecting around the edge of the door but...
(Posted by shivmc71 10 years ago)
Dryer Medb850wq0 Model
all lights on console work except ditigal timer. checked thermal fuse, door switch belts etc. all s...
(Posted by mkranch 11 years ago)
Ask a New Question
Use the box below to post a new question about this Maytag product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Maytag Manuals

Find free Maytag MEDB850WQ - Bravos 7.3 cu. Ft. Electric Dryer manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Maytag Reviews

View thousands of Maytag user reviews and customer ratings available at ReviewOwl.com.

Contact Information