Get support for Sharp CV10NH - 10,000 BTU Portable Air Conditioner

Sharp CV10NH Support Question

Sharp CV10NH Support Question

Find answers below for this question about Sharp CV10NH - 10,000 BTU Portable Air Conditioner.
Need a Sharp CV10NH manual? We have 1 online manual for this item!
Question posted by ocker2805 on July 10th, 2011

I Have A Sharp Cv10nh Air Conditioner.

It's been pluged in for less than 24 hours. My carpet is soaked. it's not wet under the unit only around. The lights are not blinking. I can't find where the water is coming from.

Current Answers

Answer #1: Posted by LorKotah on July 26th, 2011 8:51 PM
This answer was accepted by the poster of the original question.
LorKotah

Member since:
July 26th, 2011

Points: 1,100
1,100
points
(1) Either the holding tank drain plug in not inserted in the drain tube, (located on the back side, lower center location of unit)

(2) You haven't emptied the holding tank and it is somehow overflowing

Related Sharp CV10NH Manual Pages

CV-10NH Operation Manual - Page 3

... • INSTALL WINDOW PANEL E-10 • INSTALLATION AND REMOVAL OF ...HOUR OFF TIMER E-22 • TIMER OPERATION E-23 • MAIN UNIT OPERATION E-25 • DRAINAGE E-26 • MAINTENANCE E-27 • BEFORE CALLING FOR SERVICE E-28 E-1 This manual should be kept in a safe place for handy reference. ENGLISH ENGLISH This manual explains the proper use of your new air conditioner...
CV-10NH Operation Manual - Page 4

... Dealer Name Address City State Zip Telephone TO PHONE: Dial 1-800-BE-SHARP (237-4277) for: SERVICE (for your nearest Sharp Authorized Servicer) PARTS (for your daytime telephone number (including area code) and description of the unit. FOR CUSTOMER ASSISTANCE (the United States) To aid in answering questions if you call : model number, serial...
CV-10NH Operation Manual - Page 5

... will reinstall it. USERS SHARP ELECTRONICS CORPORATION warrants to Obtain Service: CV-10NH Portable Air Conditioner. In order to the ... will, at its original container, will come to your Sharp Authorized Servicer to extend the duration of ...SHARP. Some states do not allow limitations on behalf of purchase to enforce the rights under this Product. Correction of defects, in the United...
CV-10NH Operation Manual - Page 6

... agent in the latter section of this manual. • Do not modify any part of the unit. • Ensure the power supply used has an appropriate voltage rating. WARNINGS FOR USE • Install the air conditioner in water. Do not use a fuse with any part of this product. • Do not insert anything into...
CV-10NH Operation Manual - Page 7

... drainage hose must not be performed whenever moving the air conditioner. (See Page 26) If any circumstances cut or remove the round grounding pin from this plug. If a grounding adapter is equipped with obstacles. The drained water may freeze inside the hose, causing water inside the unit to overflow into a socket that has...
CV-10NH Operation Manual - Page 8

... the room. • When cooling operation is normal and does not indicate a problem with the unit. • This air conditioner blows the warm air generated by your lights or other heat-producing appliances. Any previous settings will blink. When water tank inside the unit may run at night. ENERGY EFFICIENCY TIPS • Avoid direct sunlight. A dirty filter...
CV-10NH Operation Manual - Page 9

...The air conditioner should only be placed within reach of a properly rated grounded socket. • Never place any obstacles around the air ...unit. • Allow at surfaces. For safe and secure positioning, place the unit on a smooth, level floor strong enough to support the unit. • The unit has casters to roll the unit over objects. • The unit must be rolled on carpet...
CV-10NH Operation Manual - Page 10

... signal receiver 4 window 5 5 POWER Button 6 6 OPERATION Lamp (red) 7 7 TIMER Lamp (orange) 8 9 8 MEGA COOL Lamp (green) 9 9 Air inlet 9 REAR VIEW 0 0 Exhaust air outlet q q Window exhaust adapter w w Exhaust hose e e Remote control hook r t r Air filters y t Drainage nozzle and stopcock y Power supply cord hooks u Drainpipe nozzle and stopcock u i Power supply...
CV-10NH Operation Manual - Page 12

...than 22" (559mm) wide, as you will be at the top, as indicated "A" in the diagram. E-10 Cut Window panel Window stool net Side "A" will now be at the top, as the window. (2) Open...the window panel to the window stool. If the inner width of the window is between 22" (559mm) and 24" (609mm) inclusive. Hole Insert all three projections on the window stool (3) Secure the window panel to the ...
CV-10NH Operation Manual - Page 14

... net firmly to the proper length and attach it is between 22" (559mm) and 24" (609mm) inclusive. Insect guard net Hole Projection 2 Attach the guard combined above to the insect... guard net. INSTALL WINDOW PANEL Installation in a sliding sash window (See page 10 for installation in the window panel. Insert all three projections on the window frame. (3) Secure ...
CV-10NH Operation Manual - Page 18

.... 4 Press the RESET button using a thin pointed implement. • If you will hear a CLICK if the circuit breaker is now ready for use the air conditioner if the above procedure cannot be using the unit for service. You will not be performed. E-16 The circuit breaker is activated, power is supplied, and the...
CV-10NH Operation Manual - Page 21

...air conditioner dehumidifies the room. E-19 Be sure to empty the water container whenever dehumidify mode is preset to AUTO and cannot be changed. 1 TO TURN OFF Press the POWER button again. • The red OPERATION lamp on the unit will blink... water may become less effective than 8 hours at any point, nor allow the end to be submerged in water. Failure to empty the water ...
CV-10NH Operation Manual - Page 22

... damaged. 1 Press the MODE button to outdoors. VENTILATION MODE In this mode, the air conditioner simply circulates the air without cooling it. QUIET LOW HIGH TO TURN OFF Press the POWER button again. • The red OPERATION lamp on the unit will light. • The temperature cannot be set. 1 3 Press the FAN button to set...
CV-10NH Operation Manual - Page 23

... the horizontal louvers are positioned at the lowest position in the diagram and adjust the air flow direction. Vertical louvers CAUTION Never attempt to malfunction when the remote control ... horizontal louvers can cause the unit to adjust the horizontal louvers manually. • Manual adjustment of time. ENGLISH TO CHANGE AIR FLOW DIRECTION UP / DOWN AIR FLOW DIRECTION 1 Press the...
CV-10NH Operation Manual - Page 24

...unit will turn the unit off . MEGA COOL OPERATION In this operation, the air conditioner fan works at the formerly set condition. • If you wish to operate the unit for another hour before the ONE-HOUR... control displays " ". • The orange TIMER lamp on the unit will light. • The unit will operate for an hour at extra high speed with a setting temperature of 59°F. 1...
CV-10NH Operation Manual - Page 25

.... • The orange TIMER lamp on the unit will light. • The unit will change the setting, the unit will turn on 6.5 hours later. Timer duration can set from a minimum of half an hour (30 minutes) to 12 hours, in half-hour (30-minute) increments and from 10 to a maximum of 12 hours. maining time. Up to your setting. Point...
CV-10NH Operation Manual - Page 26

... will be cancelled and will not be set from 10 to show the re- E-24 Point the remote control at the signal receiver window on the unit. 1 Press the OFF TIMER button and set the...memorized and will appear on the unit will light. 1 • The unit will emit a beep when it receives the signal. • The time setting will count down to 12 hours, in half-hour (30-minutes) increments and from...
CV-10NH Operation Manual - Page 29

... filter. Dry the filters in poor cooling performance. Carefully remove any maintenance. Insect guard net MAINTENANCE AFTER AIR CONDITIONER SEASON 1 Perform drainage to drain out water within the unit. (See Page 26 "When the unit is clogged with dust. Filters 1 REMOVE THE FILTERS • Gently pull the filter handle to the right...
CV-10NH Operation Manual - Page 30

... when, you restart the unit within the unit through the exhaust air outlet. Run the air conditioner in these modes. Although water flowing sound way be heard, this unit. Change the MODE setting.... the refrigerant flowing inside the unit is normal for about 5 minutes. • Are the OPERATION, TIMER and MEGA COOL lamps blinking? Cooling does not take place in...
CV-10NH Operation Manual - Page 60

ESPAÑOL SHARP ELECTRONICS CORPORATION Sharp Plaza, Mahwah, New Jersey 07430-2135 U.S.A SHARP CORPORATION S-31 Printed in Thailand TINSEA541JBRZ 07M- TH 1

Similar Questions

Ask a New Question
Use the box below to post a new question about this Sharp product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Sharp Manuals

Find free Sharp CV10NH - 10,000 BTU Portable Air Conditioner manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Sharp Reviews

View thousands of Sharp user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Sharp customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Sharp customer service rankings, employee comments and much more from our sister site.