Get support for Sharp ER-A520

Sharp ER-A520 Support Question

Sharp ER-A520 Support Question

Find answers below for this question about Sharp ER-A520.
Need a Sharp ER-A520 manual? We have 2 online manuals for this item!
Question posted by bookstore on November 5th, 2011

Departments

how do I program the departments?

Current Answers

There are currently no answers that have been posted for this question.
Be the first to post an answer!

Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.

Related Sharp ER-A520 Manual Pages

ER-A520 | ER-A530 Operation Manual - Page 1

ELECTRONIC CASH REGISTER MODEL ER-A520 ER-A530 INSTRUCTION MANUAL The above illustration shows the model ER-A520.
ER-A520 | ER-A530 Operation Manual - Page 3

...of the register and cause component failure. • When cleaning your machine to gain a thorough understanding of the SHARP Electronic Cash Register, Model ER-A520/A530. ...register remains plugged into the interior of 24 to 48 hours prior to malfunction. • If the register malfunctions, call your local dealer for service - This recharging precaution can prevent unnecessary equipment...
ER-A520 | ER-A530 Operation Manual - Page 4

...ER-A520 8 Front view 8 Rear view 8 EXTERNAL VIEW OF THE ER-A530 9 Front view 9 Rear view 9 PRINTER 10 KEYBOARD 11 1 ER-A520 standard keyboard layout 11 2 ER-A530 standard keyboard layout 13 3 Standard key number layout 15 4 Installing the keyboard sheet (ER...Successive multiplication entries 25 Split-pricing entries 26 Single item cash sale (SICS)/single item finalize (SIF) entries 27 ...
ER-A520 | ER-A530 Operation Manual - Page 13

... JOURNAL 0 00 • CL @ FOR RFND VOID AMT CASH # PLU/UPC INQ PRICE CHANGE Receipt paper feed key Journal ... subtotal key Department keys Automatic sequencing 1 and 2 keys Received-on-account 1 key PO FS SHIFT Paid-out 1 key Food stamp shift key 11 KEYBOARD 1 ER-A520 standard keyboard layout NC SLIP RCPT PBLU CONV RA FINAL %1 PO TAX %2 TAX SHIFT RFND VOID #/TM CASH # PLU/...
ER-A520 | ER-A530 Operation Manual - Page 17

... be changed by your authorized SHARP dealer. 3 Standard key number layout These key numbers are used for positioning of the department or direct PLU keys, please contact your dealer. For ER-A520 005 010 015 020 004 009 014 019 003 008 013 018 002 007 012 017 001 006 011 016 15...
ER-A520 | ER-A530 Operation Manual - Page 21

... please refer to a safe place. • Power save mark When the cash register goes into the power save mode, the power save mark • Cashier/...displayed. • Function message display area Item labels of departments and PLU/subdepartments/UPC and function text you use, such as %1, (-) and CASH are displayed here. When you have registered an item ten times, the display will show "0". (2...
ER-A520 | ER-A530 Operation Manual - Page 30

...scale entries Procedure When you use a programmed tare no. code Department à Unit price à or å Base wt. ` Unit price per base wt. Department OPEN TARE Open tare weight Dept....decimal) • Base weight: Up to 2 digits (integer) Note • The register can be programmed with up to nine tare tables and allows different tares to press the key. Tare number...
ER-A520 | ER-A530 Operation Manual - Page 82

... require you cannot use the direct programming. Basic instructions All the programming items can be allocated on the keyboard, you to see whether both journal and receipt rolls are missing, install journal and receipt paper rolls correctly referring to the PGM1 or PGM2 position. Plug your cash register. Installing and removing the paper roll...
ER-A520 | ER-A530 Operation Manual - Page 83

... built-in battery is equipped with 20 (ER-A520)/10 (ER-A530) standard departments and a maximum of 99 departments. and when it is set the time, the internal clock unit will be printed and displayed using the military time (24-hour) system. Your machine allows you set to perform the following programming for departments Your machine is alive...
ER-A520 | ER-A530 Operation Manual - Page 86

... Unit price (In case of programming multiple prices for a PLU/UPC code, prices for the remained levels are kept unchanged. Note P • Please note that the price lookup/subdepartment/UPC key ( for ER-A520) is shown as PLU/ UPC . • To review the UPC codes available to this register, please refer to the chapter...
ER-A520 | ER-A530 Operation Manual - Page 104

... applied to perform the following four types of 99 departments. 4 Programming for departments Your machine is equipped with scale entry (0 thru 9, 0: not used to a department programmed for "Bottle return, Hash and gas dept." Tare table number Tare table number associated with 20 (ER-A520)/10 (ER-A530) standard departments and a maximum of unit price entry for each media...
ER-A520 | ER-A530 Operation Manual - Page 112

... PLU/ UPC key. A PLU code consist of the PLU/UPC depend on the programming for the corresponding department. • Type (Bottle return/Hash/Normal) • Single item cash sale/Single item finalization • HALO (for this chapter. For UPC codes, the cash register has a UPC master file as a standard and a dynamic UPC file as PLU...
ER-A520 | ER-A530 Operation Manual - Page 145

The HALO limit is in effect for REG mode operations but can program the upper limit amounts for check cashing, check change, and cash in drawer. Key operation 2321 . @ 99 @ 9999 ı a Print High amount lockout (HALO) of entry for media keys PGM 2 2322 Direct The HALO limit is ...
ER-A520 | ER-A530 Operation Manual - Page 151

... report) RA CHK 277 RA2 check total (for trans. report) PO2 CASH 284 PO check total (for trans. report) PO FS 289 PO2 food stamp total (for trans. BAL 272 Edit tip EDIT...AMT 271 Final balance (for trans. report) RA CASH 275 RA2 cash total (for trans. report) RA2 FS 282 PO cash total (for trans. report) PO CASH 283 PO2 cash total (for trans. T. 237 Bill separate receipt title...
ER-A520 | ER-A530 Operation Manual - Page 162

... range parameter For individual reporting @ * 2 End range parameter s a To program any Job no . The range type reports needs 6, 8 or 16 steps to... department Full department group PLU/UPC PLU/UPC stock PLU/UPC zero sales PLU/UPC price category Transaction Cash ... in the stacked report sequence PGM 2 2620 Your register is equipped with the stacked report printing function that enables multiple ...
ER-A520 | ER-A530 Operation Manual - Page 168

...• Never enter any function no. (**P: 1 - 3) 2690 ** P: 1 . @ ** P (1 - 3) To program zero @ *ABCD t Ç * Item: A Channel no . for the slip printer TM-295 Select "Not connected" ... you use the model ER-A6HS1, always select the standard channel 1. ** P: 3 * Item: A Always enter 0. RS-232C channel assignment PGM 2 2690 Your register is equipped with two RS-232C interfaces...
ER-A520 | ER-A530 Operation Manual - Page 226

... following key kits, the keyboard layout can be considered, please contact your register including the expansion of the number of departments. ER-11KT7: 30 regular size key kits ER-12KT7: 30 1 x 2 size key kits ER-22KT7: 10 2 x 2 size key kits for the standard cash drawer •Key kit models By using the following Sharp options are...
Service Manual - Page 1

... of the set . SHARP CORPORATION This document has been published to change without notice. q SERVICE MANUAL CODE : 00ZERA520USME ELECTRONIC CASH REGISTER ER-A520 ER-A530 ER-A520 MODEL ER-A530 (U, A version) CONTENTS CHAPTER 1. MASTER RESET AND PROGRAM RESET 6 CHAPTER 4. CIRCUIT DIAGRAM AND PWB LAYOUT 20 PARTS GUIDE Parts marked with specified ones for after sales service only...
Service Manual - Page 2

...to 104°F) 3. CHAPTER 1. SPECIFICATIONS 1. KEY LAYOUT ER-A520 KEYLAYOUT ■ STANDARD KEY LAYOUT NC SLIP RCPT PBLU CONV RA FINAL CASH# PLU/UPC @ FOR CL 789 %1 PO TAX 456 %2 TAX SHIFT 123 RFND VOID #/TM ... key Final key No-sale key TAX 1 shift key Manual tax key Merchandise subtotal key Department keys Automatic sequencing 1 and 2 keys Received-on-account 1 key Paid-out 1 key ...
Service Manual - Page 4

...arrival/departure times. ER-A520U/ER-A530U SPECIFICATIONS - 3 - MODE SWITCH 4-1. PGM2: To program all register operations. MODE SWITCH...programs and those items that do not require frequent changes: e.g., date, time, or a variety of departments or PLUs, and percentages. OP X/Z: This setting allows cashiers to register...TRANS IN Transfer in key CA TIP Cash tip key CH TIP Charge tip key ...

Similar Questions

How To Fix The Problem Of Over Limit Sign Of Sharp Cash Register Model No. Er-a5
how to fix a problem of over limit sign on cash register of sharp of model no.ER-A520
(Posted by parinpatel0033 5 years ago)
Sharp Cash Registers Pos Er-a750
two cash registers the master reads ram error the second register blank screan key boards do nothing...
(Posted by Dearl001 8 years ago)
I Would Like To Customize My Department On My Cash Register Er-a 520 Sharp
I would like to customize my department cash registers by name like each product by his name like ci...
(Posted by maherbazzar 10 years ago)
How Do I Do A Master Reset On My Sharp Er-a520 Cash Register?
Hi! I am trying to program my cash register on the pgm1 -i type the price-hit the button i want to p...
(Posted by heather27730 12 years ago)
Ask a New Question
Use the box below to post a new question about this Sharp product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Sharp Manuals

Find free Sharp ER-A520 manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Sharp Reviews

View thousands of Sharp user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Sharp customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Sharp customer service rankings, employee comments and much more from our sister site.