Yamaha EF12000DE Support Question
Find answers below for this question about Yamaha EF12000DE - Premium Generator.Need a Yamaha EF12000DE manual? We have 1 online manual for this item!
Question posted by crazychris242448 on September 6th, 2022
Generator Will Not Turn Over It Has 12 Volts To The Starter But When I Turn Key
When I turn key on I get nothing no oil light no green light just nothing and it only has 29 hours on it it did get turned over by some not so smart people when they were moving me equipment from one site to another just wondering if it might be a sensor or a bad key switch thanks in advance for any help,CHRI
Current Answers
Answer #1: Posted by ViejoMenace on September 6th, 2022 6:58 PM
Hi, check to see if there's 12 volts to the small wire on the solenoid when the key is in the start position. If there's power there, the solenoid is likely failed or starter assembly if the solenoid is part of the starter. If there's no voltage to the small wire with the key in start position (not run position) then the problem is in the switch, or wiring. Hope that helps.
Related Yamaha EF12000DE Manual Pages
Similar Questions
Starter Won't Crank
My Yamaha EF12000DE won't turn over. Owner's manual says possible cause is a blown fuse. Where would...
My Yamaha EF12000DE won't turn over. Owner's manual says possible cause is a blown fuse. Where would...
(Posted by Anonymous-160384 7 years ago)
Starter Engages Flywheel, But Will Not Turn Off. Ignition Switch Is Ok.
(Posted by pjacoby 9 years ago)
My New $ 1,000.00 Yamaha Ef1000is Generator Continues To Leak Oil.
(Posted by Anonymous-119974 10 years ago)
As Soon As You Connect The Battery Terminal.generator Starts With Key On Off.
the stater keeps turning.Must pull wire off of silinoid to stop starter.To shut off,must pull batter...
the stater keeps turning.Must pull wire off of silinoid to stop starter.To shut off,must pull batter...
(Posted by ebasile0011 12 years ago)