110PV Surface Temperature Probe - Page 3

Warranty "PRODUCTS MANUFACTURED BY CAMPBELL SCIENTIFIC, INC. The warranty for installation services performed by Campbell such as programming to customer specifications, electrical connections to products manufactured by Campbell, and product specific training, is in materials and workmanship under this warranty. are warranted by surface carrier prepaid within the continental United States...
110PV Surface Temperature Probe - Page 4

... the product will be returned without prior authorization. Campbell Scientific reserves the right to refuse service on the outside of Product Cleanliness and Decontamination" form and comply with the requirements specified in countries served by Campbell Scientific, Inc. Affiliate companies handle repairs for customers within three days of the problem, an RMA number will be either emailed...
110PV Surface Temperature Probe - Page 6

...does not have distinctive solar cells 7 3-3. 110PV mounted to a PV module using a cable offset 5 2-5. 110PV measured with a CR1000 showing effects of cable length ..... 6 3-1. 110PV mounted to Campbell Scientific Dataloggers 10 5-1. Wiring for Example Programs 11 5-2. Steinhart-Hart Error 3 2-2. 110PV measured with a 3-wire half bridge 4 2-3. 110PV measured with a CR1000 using a 4-wire...
110PV Surface Temperature Probe - Page 7

...110PV Temperature Probe The -L portion of the probes model number indicates the probe has a user defined cable length which will be used in a wireless sensor network. The CWS900 allows the 110PV... secure the probe to as the 110PV throughout this document. 1 The aluminum disk protects the thermistor and promotes heat transfer from Campbell Scientific. For readability purposes, the probe will...
110PV Surface Temperature Probe - Page 8

...50 ft (21 psi) Linearization Error: Steinhart & Hart equation; ... Diameter: 0.245 in air. and will support combustion in . (0.622 cm) Material Disk...Specifications Temperature Range: -40° to +135°C Survival Range: -50° to +140°C 110PV...codes may preclude its resistance to temperature extremes, moisture, and UV degradation. 110PV Surface Temperature Probe The 110PV...
110PV Surface Temperature Probe - Page 14

... yellow label on a PV module. If the temperature is advisable for its flat surface. 110PV Surface Temperature Probe 3.2 Mounting to a PV Module or Other Device For mounting the probe to the... probe to the back of Kapton tape (P/N 27015) is offered by Campbell Scientific as a Common Accessory. To mount the 110PV, remove the paper from the mounting disc and adhere it to the measurement surface ...
110PV Surface Temperature Probe - Page 15

... the same excitation channel. The probe's adhesive mounting disc is preferred because it reduces cable errors (see Figures 2-2 and 2-3). Multiple probes can be adhered to a dry clean surface before submerging. Therefore the 110PV must be submerged to Campbell Scientific dataloggers are given in Table 4-1. The 3-wire half bridge method uses one single-ended input...
110PV Surface Temperature Probe - Page 16

...Lead Lengths" prior to use Edlog include our CR10, CR10X, CR23X, and CR7; 110PV Surface Temperature Probe TABLE 4-1. The coefficients used to Section 5.2. CRBasic and Edlog are ...is used for users who write their own datalogger programs. A datalogger program to Campbell Scientific Dataloggers Color Black Red Purple Blue Clear Green White Description Voltage Excitation Signal Signal...
110PV Surface Temperature Probe - Page 18

... Datalogger 'CR200 Series Datalogger 'This example program measures a single 110PV-L probe 'once a second using the ExDelSE instruction and stores 'the average temperature in Steinhart-Hart equation Const A=1....Public T110PV_Temp_F 'Declare constants to be used in degrees C every 10 minutes. '110PV-L Wiring configuration for R_cable) T110PV_Res = T110PV_Res-R_cable ' Using the Steinhart-Hart ...
110PV Surface Temperature Probe - Page 19

...F 'Define a data table for CR1000 Datalogger 'CR1000 Series Datalogger 'This example program measures a single 110PV-L probe utilizing 'the BrHalf instruction once a second and stores the average 'temperature in degrees C every 10 minutes. '110PV-L Wiring Configuration 'Lead Color CR1000 Channel Description 'Black ------ AG Signal Reference 'Blue ------- N/A 'Green------ N/A 'Clear...
110PV Surface Temperature Probe - Page 20

... (T110PV_mV,1,mV2500,1,Vx1,1,2500,True ,0,_60Hz,1.0,0) ' Convert mV to ohms T110PV_Res=4990*(1-T110PV_mV)/T110PV_mV ' Subtract off cable resistance (see 110PV-L cable for CR1000 'CR1000 Series Datalogger 'This example program measures a single 110PV-L probe utilizing the 'BRHalf4Winstruction once a second and stores the 'average temperature in Steinhart-Hart equation Const A=1.129241*10^-3 Const...
110PV Surface Temperature Probe - Page 21

...10,Min,10) Average (1,T110PV_Temp_C,FP2,False) EndTable BeginProg Scan (1,Sec,3,0) ' Measure 110PV-L probe BrHalf4W (T110PV_mV,1,mV2500,mV2500,1,Vx1,1,2500,True,True,0,_60Hz,1.0,0) ' Convert mV to... 32 CallTable AvgTemp NextScan EndProg 5.2 Edlog In Edlog, Instruction 5 is then converted to resistance and finally to measure the 110PV-L. The ratio metric output is typically used to temperature...
110PV Surface Temperature Probe - Page 23

... 1: 0000 Minutes (Seconds --) into the Settling Time parameter. 17 110PV Surface Temperature Probe ;Every ten minutes set output flag high to correct for cable resistance as shown in the ...contribute significant error (see Figure 2-6). For the CR200(X)-series, CR800, CR850, CR1000, and CR3000, the 60 and 50 Hz integration options include a 3 ms settling time; When measuring the 110PV-L in ...
110PV Surface Temperature Probe - Page 25

... PV module. Troubleshooting Symptom: Temperature is NAN, -INF, -9999, -273 Verify the red wire is connected to the correct single-ended analog input channel as specified by the measurement instruction, the black wire is connected to the switched excitation channel as specified by heating the probe to 70° to Campbell Scientific for signs...
110PV Surface Temperature Probe - Page 27

...176;C) and for low temperature shock service. Heat Resistance: Adhesive 350 is from Advanced Elastomer Systems; pp 2, 3, 9; copyright 2000. A-1 Parts should be tested for intermittent longer ...on adhesive performance. Santoprene Rubber Fluid Resistance Guide; Appendix A. Resistance: When properly applied, nameplates and decorative trim parts are generally higher after exposure to 250...

Campbell Scientific 110PV Reviews

Do you have an experience with the Campbell Scientific 110PV that you would like to share?
Earn 750 points for your review!
We have not received any reviews for Campbell Scientific yet.

Popular Campbell Scientific 110PV Search Terms

The following terms are frequently used to search for Campbell Scientific 110PV support:

Ask a New Question
Use the box below to post a new question about Campbell Scientific 110PV.
Manuals / Documents
Download any of our Campbell Scientific 110PV manuals for free!

We have the following 1 documents available for the Campbell Scientific 110PV:
  • 110PV Surface Temperature Probe
Related Items
View other Campbell Scientific Electronics Accessories:

Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Campbell Scientific Manuals

Find free Campbell Scientific 110PV manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Campbell Scientific Reviews

View thousands of Campbell Scientific 110PV user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Campbell Scientific customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Campbell Scientific customer service rankings, employee comments and much more from our sister site.