Popular Campbell Scientific CS106 Manual Pages
CS106 Barometer - Page 3
..., or shipping damage. The warranty for installation services performed by Campbell such as programming to customer specifications, electrical connections to products manufactured by Campbell Scientific, Inc. ("Campbell") to the limits extended by surface carrier prepaid within the continental United States of Campbell's product warranty. Campbell will return such products best way CIP...
CS106 Barometer - Page 4
...the nature of the problem, an RMA number will be issued. A completed form must fill out a "Statement of Product Cleanliness and Decontamination" form and comply with the requirements specified in countries served by Campbell Scientific, Inc.
The form is :
CAMPBELL SCIENTIFIC, INC. Campbell Scientific is incomplete, the product will be returned to refuse service on the outside of...
CS106 Barometer - Page 5
...SCWin Short Cut to specific sections.
1. Specifications 5
6.1 Operating Range 5 6.2 Accuracy 6 6.3 General 6
7. Table of Contents
PDF viewers: These page numbers refer to Sea Level 15
8. Initial Inspection 1
4. Introduction 1
2. Overview 5
6. Cautionary Statements 1
3. Installation 7
7.1 Jumper Settings 7 7.2 Enclosure Considerations 8 7.3 Wiring 9
7.3.1 Datalogger...
CS106 Barometer - Page 6
Signal and Ground Connectors for Alternative Pressure Units 11
ii Conversion Factors for CS106 10 7-2. CS106 jumper set to shutdown mode 7 ENC100 is a very small enclosure that can house one CS106 8 CS106 wiring diagram 9 Connector key attached to 5-pin screw terminal plug connector....... 10
Tables
7-1. Table of Contents
Figures
7-1. 7-2. 7-3. 7-4.
CS106 Barometer - Page 7
... for the range of Campbell Scientific enclosures. and will mount directly onto the holes on the backplate of 500 to not damage or cut the cable jacket. Local fire codes may result in air. However, this jacket will support combustion in permanent damage.
• Warning: Improper wiring may damage the CS106 beyond repair.
• Care should...
CS106 Barometer - Page 8
... condensation collecting in the pressure cavity, and also to use Campbell Scientific's SCWin Short Cut Program Generator. 1. Select a datalogger and scan interval.
2 Use SCWin Short Cut to Program Datalogger and Generate Wiring Diagram
The simplest method for programming the datalogger to measure the CS106 is to ensure that water cannot enter the sensor...
CS106 Barometer - Page 9
... barometric pressure measurements. Select the desired units of measure, sea level elevation correction, elevation correction units, and whether the sensor should be measured.
4. CS106 Barometric Pressure Sensor 3. Select CS106 Barometric Pressure Sensor then click the right arrow in
the middle of the page to add the sensor to the list of the...
CS106 Barometer - Page 10
Remove the yellow warning label from the pigtails and wire according to the wiring diagram generated by SCWin Short Cut. WARNING
Improper wiring may damage the CS106 beyond repair.
4
CS106 Barometric Pressure Sensor 5. Choose the outputs for the barometric pressure and then select finish.
6.
CS106 Barometer - Page 11
... in a shutdown or normal mode (see Section 7.1, Jumper Settings). Overview
The CS106 uses Vaisala's Barocap® silicon capacitive pressure sensor, which...condensing
5 Specifications
Features:
• Integral switching circuit limits power consumption to measurement cycle
• Compatible with the CS106. This barometer is shipped with all Campbell Scientific dataloggers (...
CS106 Barometer - Page 13
... is not installed, the CS106 is Santoprene® rubber.
NOTE
CS106s shipped from Campbell Scientific are configured for its use the excitation channel the datalogger must be operated in one of the cable is in normal mode and powered continuously.
Local fire codes may preclude its resistance to use inside buildings.
7. CS106 jumper set to U.L. 94 H.B. and will support...
CS106 Barometer - Page 14
... result in permanent damage.
x 3.7-in . x 5.5-in . CS106 Barometric Pressure Sensor
7.2 Enclosure Considerations
To prevent condensation, install the sensor in an environmentally protected enclosure, complete with the atmosphere, a backplate for mounting the CS106, and hardware for mounting the ENC100 to the atmosphere.
8 Campbell Scientific also offers the ENC100 for situations where...
CS106 Barometer - Page 19
... 1 4: 1 5: 0.240 6: 500
Reps 2500 mV 60 Hz Rejection Range SE Channel Loc [ CS106 ] Multiplier Offset
13 CS106 Barometric Pressure Sensor
BeginProg PipeLineMode
Scan (1,sec,3,0)
'Measurement is made every scan outside the "If" statement ... CR10X, other Edlog dataloggers, such as above )
3: 41
Set Port 1 High
;Measure CS106 at the top of the hour 'Turn off .
;{CR10X}
*Table 1 Program
01:...
CS106 Barometer - Page 20
This voltage drop, in Edlog) to measure the CS106.
7.4.4 Output Resolution
When storing the values from the CS106 to a datalogger's final storage location, or to a data table, care must be displayed is 7999 for the CRBasic dataloggers and 6999 for Campbell Scientific dataloggers is limited to a maximum of four digits. Even then, the maximum digit...
CS106 Barometer - Page 21
CS106 Barometric Pressure Sensor
option with a damp, lint-free cloth and a mild detergent solution. To retain 0.01 mb resolution, you either need to subtract a fixed offset from the reading before it is IEEE4.
7.5 Correcting Pressure to Sea Level
The weather service...500 mb in our example programs) in the measurement instruction.
U.
M. Hobbes, 1977: Atmospheric Science: An ...
CS106 Barometer - Page 22
...sensitive to purchase the part. To avoid damage, take adequate anti-static measures when handling.
16 Contact Campbell Scientific, Inc. CS106 Barometric Pressure Sensor
CAUTION
Contact Campbell Scientific, Inc. (435-227-9000) for an RMA number before returning the sensor for recalibration.
Should you lose the five terminal connector (p/n 16004), the replacement part can be purchased from...