Campbell Scientific A150 Support and Manuals
Get Help and Manuals for this Campbell Scientific item
This item is in your list!
View All Support Options Below
Free Campbell Scientific A150 manuals!
Problems with Campbell Scientific A150?
Ask a Question
Free Campbell Scientific A150 manuals!
Problems with Campbell Scientific A150?
Ask a Question
Popular Campbell Scientific A150 Manual Pages
A150 Desiccated Case - Page 2
...
PRODUCTS MANUFACTURED BY CAMPBELL SCIENTIFIC, INC. The following contact information is part of nature, or shipping damage. To all other warranties, expressed or implied. The warranty for installation services performed by Campbell such as programming to customer specifications, electrical connections to products manufactured by Campbell, and product specific training, is for...
A150 Desiccated Case - Page 3
...to the printed version of this document. A150 Interior 2 3. CWS900 Connector Pin-Out 3 4. A150 with PWENC Connector 4 6. Physical Description 2 3. Installation 6
5.1 Mounting 6 5.2 Wiring...6
Figures
1. A150 Desiccated Case 1 2. A150 with CWS900 Connector 5 8. A150 Wired for links to specific sections.
1. Function 1
1.1 Typical Applications 1 1.2 Compatibility 1
2. Use...
A150 Desiccated Case - Page 5
...a continuation cable, a PWENC connector, or a CWS900 wireless sensor connector. Utilizing the A150, a sensor may be connected to the datalogger. The sensor is compatible with multiple ...prewired enclosure.
Lid
Chassis
Cable Gland Mounting Bracket FIGURE 1. A150 Desiccated Case
1. Function
1.1 Typical Applications
The A150 desiccated case is a small, self-contained junction box that...
A150 Desiccated Case - Page 6
... choosing.
2 Four screws secure the lid to insert more than one wire into the terminal block. A150 Interior
2. A mounting bracket is used with the included Velcro® strap, to the current atmospheric ...the lever nut into each connection on the bottom of the unit. When used to fasten the A150 inside the chassis. A terminal block is mounted inside an enclosure or, with a CWS900, ...
A150 Desiccated Case - Page 7
... A150 correspond to the datalogger through a wireless sensor network. Specifications...replacement part number 27373)
Cable Gland Min/Max Cable Diameter: 4.6 mm/7.9 mm (0.181"/0.312")
Desiccant Bag (1/2 Unit) Replacement Part Number: 905 Velcro® Strap Replacement Part Number: 5487
Humidity Indicator Card Replacement Part Number: 6571
4.
The third option includes a connector to attach the A150...
A150 Desiccated Case - Page 8
...installer to the datalogger. Figure 6 gives an example of an anemometer wired to the A150.
4.2 #22018 PWENC Connector
Figure 5 shows the A150 terminal block with a 26972 continuation wire attached. This configuration allows a CS450 or other sensor to be attached to the A150... a CS450 or other sensor to be attached to the A150 while the PWENC connector completes the connection to be measured...
A150 Desiccated Case - Page 9
... Shield
Vent TUBE
N.C. WHITE BLUE GREEN RED BLACK CLEAR
#26972 Cable
5 (Pin #) 2 1 #19520 4 CWS900 Connector 3 6
BLACK
FIGURE 7.
A150
WHITE BLUE GREEN RED BLACK CLEAR
#26972 Cable
Terminates in A150 Enclosure
5 (Pin #) 2 1 #19520 4 CWS900 Connector 3 6
FIGURE 8. A150 Desiccated Case
Anemometer
BLACK Signal Pulse WHITE Signal Reference CLEAR Shield
WHITE BLUE GREEN RED BLACK CLEAR...
A150 Desiccated Case - Page 10
... with the sensor, or contact a Campbell Scientific Applications Engineer, for mounting.
Once all wires are attached, tighten the wire gland to use the mounting bracket on the back of each wire to the terminal block adjacent to the corresponding wire to the datalogger or CWS900. Installation
5.1 Mounting
The A150 provides two options for the...