Fluke 1625-2 Support and Manuals
Get Help and Manuals for this Fluke item
This item is in your list!
View All Support Options Below
Free Fluke 1625-2 manuals!
Problems with Fluke 1625-2?
Ask a Question
Free Fluke 1625-2 manuals!
Problems with Fluke 1625-2?
Ask a Question
Popular Fluke 1625-2 Manual Pages
User Manual - Page 1
Specifications are trademarks of their respective companies. All rights reserved. All product names are subject to change without notice. 1625-2
Earth/Ground Tester
Users Manual
January 2014
© 2014 Fluke Corporation.
User Manual - Page 3
... All Data Settings with Personalized CODE 37 Export Stored Data to Contact Fluke 2 Safety Information 3 Storage...4 Models and Accessories 5 Additional Accessories 6 Features ...7 Display ...9 Setup ...13
Batteries...13 Description of Contents
Title
Page
Introduction ...1 How to PC 39 Delete Stored Data 40 Maintenance...41 Calibration ...41 Service ...41 Specifications ...42
i Table...
User Manual - Page 9
... the most fundamental safety measure. The Tester features: • One-button measurement concept • 3-pole and 4-pole earth ground measurement • 4-pole soil resistivity testing • Selective testing, no disconnection of earth ground measurement. Introduction
The 1625-2 Earth Ground Tester (Tester or Product) is able to measure earth ground loop resistances using only clamps -
User Manual - Page 10
...power pylon grounds. 1625-2
Users Manual
The effectiveness of grounding systems should be purchased. (The1625-2 Kit includes this clamp set.) • Selective measurements are described in the main section of this manual. • For stakeless earth resistance measurements, the Selective/Stakeless
Clamp Set (EI-1623) must be checked using a earth/ground tester such as the 1625-2 which checks...
User Manual - Page 12
1625-2
Users Manual
Table 1 is a list of electrical shock. See Manual. Risk of symbols used on the Tester and in this product as category 9 "Monitoring and Control Instrumentation" product.
Go to relevant Australian EMC requirements. Important information. Conforms to Fluke's website for recycling information. This product complies with the WEEE Directive (2002/96/EC) marking ...
User Manual - Page 13
...
Part Number
1625-2 Earth Ground Tester (Includes Users Manual, Safety Information, QRG, Geox Probe Cable, 2 clips, Lead set)
4325162
1625-2 Kit Earth Ground Tester Kit (Includes Users Manual, Safety Information, QRG, Geox Probe Cable, 2 clips, Lead set, 4 Earth Stakes, 3 Cable Reels, C1620 Carrying Case, EI162X, EI-162AC)
4325181
162x-7001 Service Replacement Kit (Includes Lead set...
User Manual - Page 15
... instrument with fully automated measuring frequency selection process. The Tester includes automatic testing of earthing resistance measurements. See Table 3 for use as a simple meter as well as a high end fully automated measuring device. Earth/Ground Tester
Features
Features
The 1625-2 Earth/Ground Tester (Tester) is an earth resistance meter with force. • Disconnect all leads before...
User Manual - Page 21
...instrument, see Figure 2. 2. Disconnect all test leads. 3. Contact service.
The symbol may be used but must be different to those available using the stakeless measurement on display
edw052.eps
Setup
Batteries
Note
Rechargeable batteries may appear when using alkaline cells.
Always replace the complete set of measurements available with six 1.5 V batteries IEC LR6...
User Manual - Page 22
... personal injury: • The battery door must be closed and locked before use if the battery leaks. • Be sure that the battery polarity is correct...Product: • Repair the Product before you operate
the Product. • Replace the batteries when the low battery indicator shows to prevent battery
leakage. edw070.eps
14 1625-2
Users Manual
1
2
1625B EARTH / GROUND TESTER
3
4
+...
User Manual - Page 28
... a specific measurement can be carried out for up to the mains frequency (55 Hz) is carried out. See Figure 3. Additionally, one of the four measuring frequencies can be called and displayed with Personalized CODE). They can be performed without separating parts of earthing impedance (R*) are not activated at delivery. The corresponding measuring frequency used for Earthing...
User Manual - Page 30
1625-2
Users Manual
Remarks for the setting of earth spikes:
Before setting the earth spikes for probe and auxiliary earth electrode make sure that the probe is set outside the potential gradient area of the earth spikes to each other . Such a condition is caused by allowing a distance of >20 m between the earth electrode and the earth spikes as well as earth electrode connecting...
User Manual - Page 32
...used.
The instrument is correct for the EI162X sensing clamp.
24
Make sure that is preset from factory is to be measured. Note The ratio that the clip-on transformation ratio set on the display.
1
2
4 Probe E/C1
S/P2
H/C2
3
4
START
Earth...Change All Data Settings with Personalized Code). 1625-2
Users Manual
3-Pole/4-Pole Measurement of Single Earth Electrode Resistances
Turn...
User Manual - Page 36
... transformer, a part of the measuring current is sufficient. Such a condition is set outside the potential gradient of earth electrode and auxiliary earth electrode.
Keep ... another measurement after repositioning of auxiliary earth electrode or probe. 1625-2
Users Manual
Notices for the setting of earth spikes:
Before setting the earth spikes for each other. Current feeding...
User Manual - Page 48
...Tester to the PC. 2. Use Windows Explorer on the EGT drive. 4. 1625-2
Users Manual
Table 8. Sample .CSV File for Logged Data (cont.)
Measurement Interferenc e Frequency Fst Interferenc e
Current Earthing Impedance 55 Hz R* Earth Ground...
R 2 Probe Resistance Rs Auxilliary Resistance Rh Compensation Resistance Rk Transforme r Ratio I Error Status
1 NA 2 NA 3 NA 4 NA 5 NA 6 1.022 Ω...
User Manual - Page 49
In all repair work must only be closed and locked before you clean the Product.
Warning For safe operation and maintenance of the problem. Service
If you suspect that the tester has failed, review this manual to make sure you operate
the Product. • Replace the batteries when the low battery indicator shows to the original...
Fluke 1625-2 Reviews
Do you have an experience with the Fluke 1625-2 that you would like to share?
Earn 750 points for your review!
We have not received any reviews for Fluke yet.
Earn 750 points for your review!