Popular Fluke 87-5 CAL Manual Pages
Product Manual - Page 4
... Mode 31 HiRes Mode (Model 87 31 MIN MAX Recording Mode 32 Smooth Feature (Power Up Option Only 32 AutoHOLD Mode...34 Relative Mode ...34 Maintenance ...35 General Maintenance 35 Fuse Test ...35 Replacing the Battery 36 Replacing the Fuses 37 Service and Parts...37 Specifications...43 Detailed Specifications 44
ii
MyFlukeStore Shop for Fluke products online at: www...
Product Manual - Page 5
...Frequency Measurements 28 7. Temperature Specifications (87 Only 47 14. Functions and Trigger Levels for Fluke products online at: www.
.com 1.888.610.7664 MIN MAX Functions...33 8. List of the Terminals 51 19. Pushbuttons ...8 5. Replacement Parts ...39 9. DC Voltage, Resistance, and Conductance Function Specifications 46 13. Model 87 AC Voltage Function Specifications 44 11.
Product Manual - Page 7
Introduction
XW Warning
Read "Safety Information" before you use the Meter. Model 87 appears in this manual apply to Series V Models 83 and 87 multimeters (hereafter referred to as "the Meter").
Multimeters Introduction
1
MyFlukeStore Shop for Fluke products online at: www.
.com 1.888.610.7664
Except where noted, the descriptions and instructions in all illustrations.
Product Manual - Page 14
... automatic power-off feature (Meter normally powers off in 30 minutes). The Meter reads "CAL" and enters calibration mode. Enables the Meter's smoothing feature. To return to autoranging, hold for 1 second) Enables the Meter's calibration mode and prompts for Fluke products online at: www.
.com 1.888.610.7664
Pushbuttons
Button
A
(Yellow)
B C
Switch Positon
N
M
J
P Q
Power...
Product Manual - Page 18
... described under "Zoom Mode".
Have Meter serviced.
80 Series V Users Manual
Table 5. Overload condition is relative to the terminal being tested. Invalid model.
Display Features (cont.)
Number Feature
...Fluke products online at the left .
For more information, see "Bar Graph".
Calibrate Meter. The polarity indicator at : www.
.com 1.888.610.7664
Have Meter serviced...
Product Manual - Page 22
...above serial number 90710501 and OL for continuity, set up the Meter as shown in Figure 4.
Turn... a type-K thermocouple to 260 °C. 80 Series V Users Manual
Measuring Temperature (87)
The Meter measures the temperature of that sounds as long as ...;F to 1994.0 °F, the included K-Type Thermocouple is rated for Fluke products online at: www.
.com 1.888.610.7664 The continuity function...
Product Manual - Page 38
... "'___" until C is active. Model 83 has 100 millisecond response time;
MyFlukeStore Shop for Fluke products online at a new value to...Model 87 has 100 millisecond, and 250 μs (peak) response times.
This mode can also calculate an average of the display to be used to the functions in the 100 ms mode is the mathematical integral of all recorded readings. 80 Series V Users Manual...
Product Manual - Page 41
... Table 8 for Fluke products online at: www.
.com 1.888.610.7664 If the tests give readings other than those shown, have the Meter serviced. Turn the Meter...replaced. To prevent damage or injury, install ONLY specified replacement fuses with a damp cloth and mild detergent. Maintenance
XW Warning
To avoid possible electric shock or personal injury, repairs or servicing not covered in this manual...
Product Manual - Page 42
...Fluke products online at: www.
.com 1.888.610.7664 Remove the battery door by turning the screws one-quarter turn counterclockwise.
3. If the display shows bAtt the Meter will not function until the battery is replaced. 80 Series V Users Manual...
Good F2 fuse: 00.0 Ω to 00.5 Ω
Replace fuse: OL
Touch top half of input contacts
87 V TRUE ...
Product Manual - Page 46
... Clip, Red Test Lead Set Thermocouple Assembly, K-Type, Beaded, Molded Dual Banana Plug, Coiled Access Door Fastener Tiltstand LCD, 4.5 DIGIT,TN, Transflective, Bar Graph, OSPR80 Lightpipe Keypad 80 Series V Multi-Language Getting Started Manual 80 Series V Quick Reference Card CD ROM,80 Series V User Manual
Qty.
1 1 1 1 2 1 1 1 1 1 1 1
Fluke Part or Model Number
1670652 1670641 855742 1273113...
Product Manual - Page 50
...10.
For Model 87 in the 4 ½-digit mode, multiply the number of range. Table 10. Model 87 AC Voltage Function Specifications
Function Range ...calibration. 80 Series V Users Manual
Detailed Specifications
For all detailed specifications:
Accuracy is in use.
44
MyFlukeStore Shop for Fluke...error in the ac functions, the Meter may display a residual reading between
1 and 30 counts.
Product Manual - Page 51
...kHz - 5 kHz ± (2.0 % + 4) ± (2.0 % + 4) ± (2.0 % + 4) ± (2.0 % + 4)2 unspecified
45
MyFlukeStore Shop for Fluke products online at: www.
.com 1.888.610.7664 Below a reading of 200 counts, add 10 counts. 2. Model 83 AC Voltage Function Specifications
Function
Range
Resolution
K1
600.0 mV 0.1 mV
6.000 V
0.001 V
60.00 V
0.01 V
600.0 V
0.1 V
1000 V
1 V
1. Table...
Product Manual - Page 52
... 33 nS in the 60 nS range.
46
MyFlukeStore Shop for offsets. 2. 80 Series V Users Manual
Table 12. DC Voltage, Resistance, and Conductance Function Specifications
Function
Range
Resolution
Model 83
Accuracy
Model 87
6.000 V
0.001 V
± (0.1 % + 1)
± (0.05 % + 1)
L
60.00 V
0.01 V
± (0.1 % + 1)
± (0.05 % + 1)
600.0 V
0.1 V
± (0.1 % + 1)
± (0.05...
Product Manual - Page 54
... the rms value of a sine wave input.
2. Model 87 is ac coupled and calibrated to 35 °C; < 20 minutes on, 5 minutes off at : www.
.com 1.888.610.7664 A 30 count residual reading will cause only a 2 digit change for 30 seconds maximum; > 10 A unspecified. 5. 80 Series V Users Manual
Function
mA \
(45 Hz to 2 kHz)
mA...
Product Manual - Page 58
...Recording Specifications
Model
...Model 87 only)1 Specified accuracy ± 100 counts for changes > 250 μs in duration
(add ± 100 counts for readings over 6000 counts)
(add ± 100 counts for Fluke ...products online at: www.
.com 1.888.610.7664 For repetitive peaks: 1 ms for single events.
52
MyFlukeStore Shop for readings in Low Pass mode)
1. 80 Series V Users Manual...