Product Manual - Page 2
... to invoice Buyer for importation costs of repairs/replacement parts when product purchased in one year for Fluke products online at Hart's option, to refund of the purchase price, free of charge repair, or replacement of the difficulty, postage, and insurance prepaid (FOB Destination), to the nearest Hart authorized service center.
Hart assumes no authority to be...
Product Manual - Page 3
... Testing 9 1.5.4 Low Voltage Directive (Safety 9 1.6 Authorized Service Centers 9
2 Specifications and Environmental Conditions 13
2.1 Specifications 13 2.2 Environmental Conditions 15
3 Quick Start 17
3.1 Setup...17 3.2 Parts and Controls 18
3.2.1 Display Panel 19 3.2.2 Display...20 3.2.3 Power Panel 22 3.2.4 -P Option Panel (-P models only 24 3.3 Languages 26 3.3.1 Language Selection...
Product Manual - Page 6
... display 21 Figure 5 9142 power panel 23 Figure 6 9143 and 9144 power panel 23 Figure 7 -P option panel 24 Figure 8 Probe connector wiring 25 Figure 9 Jumper locations for Fluke products online at: www.
.com 1.888.610.7664 Temp SetUp 29 Figure 12 Main Menu - Prog Menu 30 Figure 13 Auto and manual switch test operation...
Product Manual - Page 7
...or heaters to 33°C). The display can be set -point, block stability, and heating and cooling ...You Start
Introduction
1.1 Introduction
Field Metrology Wells (9142, 9143, and 9144) are designed to be...(Patent Pending) keeps the axial gradient within specification over the entire temperature range of temperature
...176;C. The readout is no need for Fluke products online at: www.
.com 1.888...
Product Manual - Page 8
... that the following components are present:
9142 ●● 9142 Field Metrology Well ●● 9142-INSX Insert (X=A, B, C, D, E, or F) ●● Power Cord ●● RS-232 Cable ●● User Guide ●● Technical Manual CD ●● Report of Calibration and calibration label ●● 6-pin DIN Connector (-P model only) ●● Test Lead...
Product Manual - Page 9
...not present, contact an Authorized Service Center (see Section 1.6 Authorized Service Centers on the instrument or in this guide.
Before You Start
Symbols ...Guide ●● Technical Manual CD ●● Report of Calibration and calibration label ●● 6-pin DIN Connector (-P model only) ●● Test Lead Kit (-P model only) ●● Clamp-on ferrites (3) [-P model...
Product Manual - Page 16
914X Field Metrology Wells
Authorized Service Centers
When contacting a Service Centers for support, please have the following information available:
●● Model Number ●● Serial Number ●● Voltage ●● Complete description of the problem
10
MyFlukeStore Shop for Fluke products online at: www.
.com 1.888.610.7664
Product Manual - Page 19
... and Environmental Conditions
Specifications
2 Specifications and Environmental Conditions
2.1 Specifications
Table 2 Base Unit Specifications
Base Unit Specifications
9142
9143
9144
Temperature Range at 23 °C
Display Accuracy
-25 °C to 150 °C (-...keys 290 mm x 185 mm x 295 mm (11.4 x 7.3 x 11.6 in)
13
MyFlukeStore Shop for Fluke products online at: www.
.com 1.888.610.7664
Product Manual - Page 20
914X Field Metrology Wells
Specifications
Base Unit Specifications
9142
9143
9144
Weight Power Requirements
System Fuse Ratings
4-20 mA Fuse (-P model only) Computer Interface Safety
8.16 kg (18 lbs)
100 V to 115 V (± 10 %) 50/60 Hz, 635 W
230 V...120, Resistance
2-,3-,4-wire RTD w\ Jumpers only
4 terminal input
14
MyFlukeStore Shop for Fluke products online at: www.
.com 1.888.610.7664
Product Manual - Page 23
... switch on the front of free space around the instrument. Contact an Authorized Service Center for Fluke products online at least 6 inches of the calibrator. 3 Quick Start
Quick Start
Setup
3.1 Setup
Note: The instrument will not heat, cool, or control until the "SET PT." Plug the instrument power cord into the well. Observe that indicated...
Product Manual - Page 27
...21
MyFlukeStore Shop for Fluke products online at the bottom of the display (not shown) indicate the functions of the soft keys (F1-F4). Quick Start
Parts and Controls
Stability ... models only] When installed, the most recent UUT output measurement is a bar graph that will find a graph displaying the current status of the stability of the Field Metrology Well. Editing Windows While setting ...
Product Manual - Page 35
Invalid key entry
Code Update Mode Keys
ENTER & EXIT Keys (hold during power up) Allows instrument software to be updated
Figure 11 Main Menu - Key - EDIT PRESET F4 - Valid key entry 2 Beep - Temp SetUp
29
MyFlukeStore Shop for Fluke products online at which the Field Metrology Well increases or decreases temperature
STABLE LIMIT: The defined minimum...
Product Manual - Page 36
...O.f CYCLES: Number of times the Field Metrology Well repeats the manual test program
F4
TEST RESULT (-P only)
F1
VIEW TESTS
DISPLAY...888.610.7664 Prog Menu
30
MyFlukeStore Shop for Fluke products online at the set point temperature
Number O.f CYCLES: Number of times the...Menu
4.2 Prog Menu
9142/9143/9144 MAIN MENU
F1
TEMP SETUP
F2
PROG MENU
F3
SYSTEM MENU
F4
INPUT SETUP (-P only)
F1...
Product Manual - Page 37
...610.7664 The Switch Test allows for Fluke products online at the rate specified in "Scan Rate" found in the Temp Setup menu, select Setup and enter the SCAN RATE.
Set the Test Method to the Prog ...begin testing if the test is within a few seconds. CYCLES
The NO. For Manual operation, in MAIN MENU|TEMP SETUP|SETUP|SCAN RATE. Exit to AUTO.
Under Switch Test, select Auto Test. Exit ...
Product Manual - Page 39
...9142/9143/9144 MAIN MENU
F1
TEMP SETUP
F2
PROG MENU
F3
SYSTEM MENU
F4
INPUT SETUP (-P only)
F1
SYSTEM SETUP
F1
DISPLaY SETUP
LANGUAGE:
DECIMAL:
KEY AUDIO:
F2
COMMunication SETUP
BAUD RATE:
LINEFEED:
F3
DATE TIME (-P only)
TIME:
DATE:
DATE FORMAT:
TIME STAMP:
F2
PASSWORD
USER PASSWORD...MODEL:
SERIAL number:
FirmWare VERsion:
CALibration DATE:
INPUT CALibration DATE...
Fluke 9142-A-156 Reviews
Do you have an experience with the Fluke 9142-A-156 that you would like to share?
Earn 750 points for your review!
We have not received any reviews for Fluke yet.
Earn 750 points for your review!