User Manual
Page 54
... WEB authentication. Enter the IP Address Filter interface: Configuration > System > Security > IP Address Filter Figure 6-16 IP Address Filter Interface 2. Network Camera User Manual Figure 6-15 Authentication 2. Set up authentication method for better data security. Set the IP Address Filter list. Add an IP Address 44 Click Save to save...
... WEB authentication. Enter the IP Address Filter interface: Configuration > System > Security > IP Address Filter Figure 6-16 IP Address Filter Interface 2. Network Camera User Manual Figure 6-15 Authentication 2. Set up authentication method for better data security. Set the IP Address Filter list. Add an IP Address 44 Click Save to save...
User Manual
Page 114
... to detect 104 Check the checkbox of the sound intensity, and some certain actions can be taken when the alarm is triggered. Steps: 1. Figure 10-15 Audio Exception Detection 2. These events can trigger the linkage methods, such as Notify Surveillance Center, Send Email, Trigger Alarm Output, etc. 10.2.1 Configuring Audio Exception...
... to detect 104 Check the checkbox of the sound intensity, and some certain actions can be taken when the alarm is triggered. Steps: 1. Figure 10-15 Audio Exception Detection 2. These events can trigger the linkage methods, such as Notify Surveillance Center, Send Email, Trigger Alarm Output, etc. 10.2.1 Configuring Audio Exception...
User Manual
Page 152
... Detection, Alarm, Motion | Alarm, Motion & Alarm, and Event. Continuous If you select Continuous, the video will be configured as No Pre-record, 5s, 10s, 15s, 20s, 25s, 30s or not limited. Post-record: The time you select Motion Detection, the video will be configured as 5s, 10s, 30s, 1 min...
... Detection, Alarm, Motion | Alarm, Motion & Alarm, and Event. Continuous If you select Continuous, the video will be configured as No Pre-record, 5s, 10s, 15s, 20s, 25s, 30s or not limited. Post-record: The time you select Motion Detection, the video will be configured as 5s, 10s, 30s, 1 min...
User Manual
Page 169
will be searched and displayed in the list in 15 seconds after it will be removed from the subnet where your subnet and displays the information of the devices using this software. Search active ...devices online Search online devices automatically After launch the SADP software, it automatically searches the online devices every 15 seconds from the list in the Online Devices interface. Note: Figure A.1.1 Searching Online Devices Device can also modify the basic network information of the devices...
will be searched and displayed in the list in 15 seconds after it will be removed from the subnet where your subnet and displays the information of the devices using this software. Search active ...devices online Search online devices automatically After launch the SADP software, it automatically searches the online devices every 15 seconds from the list in the Online Devices interface. Note: Figure A.1.1 Searching Online Devices Device can also modify the basic network information of the devices...
Quick Start Guide
Page 4
... equipment has been tested and found to comply with the instructions, may cause harmful interference to operate the equipment. These limits are designed to part 15 of the following measures: -Reorient or relocate the receiving antenna. -Increase the separation between the equipment and receiver. -Connect the equipment into an outlet on...
... equipment has been tested and found to comply with the instructions, may cause harmful interference to operate the equipment. These limits are designed to part 15 of the following measures: -Reorient or relocate the receiving antenna. -Increase the separation between the equipment and receiver. -Connect the equipment into an outlet on...
Quick Start Guide
Page 5
... European standards listed under the EMC Directive 2014/30/EU, the RoHS Directive 2011/65/EU 2012/19/EU (WEEE directive): Products marked with part 15 of the FCC Rules. Operation is marked with this symbol, which may include lettering to the following two conditions: 1. This device may cause undesired operation...
... European standards listed under the EMC Directive 2014/30/EU, the RoHS Directive 2011/65/EU 2012/19/EU (WEEE directive): Products marked with part 15 of the FCC Rules. Operation is marked with this symbol, which may include lettering to the following two conditions: 1. This device may cause undesired operation...
Quick Start Guide
Page 9
... Contents 1 Appearance Description 10 1.1 Type I Bullet Camera 10 1.2 Type II Bullet Camera 11 1.3 Type III Bullet Camera 12 1.4 Type IV Bullet Camera 13 2 Installation 15 2.1 Memory Card Installation 15 2.2 Type I, II, III Cameras Mounting 17 2.2.1 Direct Mounting 17 2.2.2 Mounting with a Junction Box 20 2.2.3 Mounting with a Gang Box 22 2.3 Type IV Camera Mounting...
... Contents 1 Appearance Description 10 1.1 Type I Bullet Camera 10 1.2 Type II Bullet Camera 11 1.3 Type III Bullet Camera 12 1.4 Type IV Bullet Camera 13 2 Installation 15 2.1 Memory Card Installation 15 2.2 Type I, II, III Cameras Mounting 17 2.2.1 Direct Mounting 17 2.2.2 Mounting with a Junction Box 20 2.2.3 Mounting with a Gang Box 22 2.3 Type IV Camera Mounting...
Quick Start Guide
Page 16
Follow the steps to expose the memory card slot. 15 The IR light from the camera may reflect back into the lens causing reflection. 2.1 Memory Card Installation Type II, Type III and Type IV cameras ...
Follow the steps to expose the memory card slot. 15 The IR light from the camera may reflect back into the lens causing reflection. 2.1 Memory Card Installation Type II, Type III and Type IV cameras ...
Quick Start Guide
Page 27
Network Bullet Camera·Quick Start Guide Panning: 0°to 360° Tilting: -30°to 15° Adjusting Screw Tilting: 0°to 90° Adjusting Knob Panning: 0°to 360° Figure 2-14 Adjust the Angle 2.4 (Optional) Network Cable Waterproof Jacket Installation 26
Network Bullet Camera·Quick Start Guide Panning: 0°to 360° Tilting: -30°to 15° Adjusting Screw Tilting: 0°to 90° Adjusting Knob Panning: 0°to 360° Figure 2-14 Adjust the Angle 2.4 (Optional) Network Cable Waterproof Jacket Installation 26
Quick Start Guide
Page 28
Components 1 Camera's Network Interface Socket 2 O-Type Gasket 3 Network Plug 4 Waterproof Endcap 5 Waterproof Rubber Gasket 6 Lock Nut 7 Network Cable from Router/Switch 27 Network Bullet Camera·Quick Start Guide Purpose: If the camera is installed outdoor, you can adapt the waterproof accessory for the network cable after the camera is secured on the installation surface. ①② ③ ④ ⑤ ⑥⑦ Figure 2-15 Waterproof Accessory Components Table 2-1 Components No.
Components 1 Camera's Network Interface Socket 2 O-Type Gasket 3 Network Plug 4 Waterproof Endcap 5 Waterproof Rubber Gasket 6 Lock Nut 7 Network Cable from Router/Switch 27 Network Bullet Camera·Quick Start Guide Purpose: If the camera is installed outdoor, you can adapt the waterproof accessory for the network cable after the camera is secured on the installation surface. ①② ③ ④ ⑤ ⑥⑦ Figure 2-15 Waterproof Accessory Components Table 2-1 Components No.
Data Sheet
Page 2
...12 VDC ± 25%, 7.5W; Package: 15.2" x 6.14" x 6.1" (386 mm × 156 mm × 155 mm) Weight 2.65 lbs (1200 g) Accessories CBS Junction Box Hikvision USA Inc., 18639 Railroad Street, City of Industry, CA 91748, USA • Hikvision Canada, 4485 Dobrin, St-Laurent, Quebec, Canada...trigger linkage method General Operating Conditions -22° F to 140° F (-30° C to change without notice. 032619NA Specifications DS-2CD2T25FWD-I5 Camera Image Sensor 1/2.8" Progressive Scan CMOS Minimum Illumination Color: 0.008 lux @(F1.6, AGC ON), 0 lux with IR Shutter Time 1/3 s to ...
...12 VDC ± 25%, 7.5W; Package: 15.2" x 6.14" x 6.1" (386 mm × 156 mm × 155 mm) Weight 2.65 lbs (1200 g) Accessories CBS Junction Box Hikvision USA Inc., 18639 Railroad Street, City of Industry, CA 91748, USA • Hikvision Canada, 4485 Dobrin, St-Laurent, Quebec, Canada...trigger linkage method General Operating Conditions -22° F to 140° F (-30° C to change without notice. 032619NA Specifications DS-2CD2T25FWD-I5 Camera Image Sensor 1/2.8" Progressive Scan CMOS Minimum Illumination Color: 0.008 lux @(F1.6, AGC ON), 0 lux with IR Shutter Time 1/3 s to ...