Rheem 13AJN Support and Manuals

Get Help and Manuals for this Rheem item

View All Support Options Below
Free Rheem 13AJN manuals!
Problems with Rheem 13AJN?

Ask a Question

Most Recent Rheem 13AJN Questions

Rebates
Are there rebates available for 3 ton horizontal units?
(Posted by christineslaton 5 years ago)
Air Handler Rhlp-hm36ja
For 13ajn36 3 Ton 13 Seer What Air Handler Should Be Used.'what About Can't Find It
(Posted by pattybrown 10 years ago)
I've Removed The Filter From My Rheem Ac/heater To Clean It And Want To Know How
The filter wont go all the way back in. How do I get it back in without forcing it
(Posted by stuartnlutwak 10 years ago)

Popular Rheem 13AJN Manual Pages

Brochure - Page 1

Air Air Conditioners 13AJN Series reliability at an AFF RDABLE PRICE With the Rheem Value Series Air Conditioner, you get a higher level of comfort that every lifestyle deserves, and every budget can handle. 13AJN Series Efficiencies up to 14.5 SEER Energy Savings Innovative comfort solution based on established technologies provides continuous cooling and a reduction in your home's energy ...
Brochure - Page 2

...Rheem.com/Contractors. 13.0 Proper sizing and installation of Reliable Comfort The Rheem Value Series Air Conditioner is critical to meet ENERGY STAR® criteria. To learn more . Our Protection Plus® extended service... review magazine. We've designed the Rheem Value Series to come. Benefits At-A-Glance Efficiency: Up to 14.5 SEER/12 EER Available Sizes: 1.5 - 5 ton Compressor...
Specifications - Page 1

Air Conditioners Air 13AJN Series Rheem Value Series Air Conditioners 13AJN- not installed) FORM NO. Series Efficiencies up to 14.5 SEER/12 EER Nominal Sizes 1.5-5 Ton [5.28 to 17.6 kW] Cooling Capacities 16.6 to 58 kBTU [4.86 to 17.0 kW] 16.0 "Proper sizing and installation of equipment is critical to achieve optimal performance. These units offer comfort and dependability for single, multi-...
Specifications - Page 2

Table of Contents Air 13AJN Series TABLE OF CONTENTS Model Features ...3 Model Number Identification 4 Accessories...4 Scroll Compressor 4 Performance Data 5-21 Electrical & Physical Data 22 Unit Dimensions 23 Refrigerant Line Size Information 24 Limited Warranty 25 2
Specifications - Page 3

...and light commercial applications. ■ Painted louvered steel cabinet ■ Easily accessible control box Model Features Air 13AJN Series ■ Condenser coils constructed with copper tubing and enhanced aluminum fins ■ Grille/Motor mount for ground level or rooftop installations. Model Features: ■ Outdoor condensing unit designed for quiet fan operation ■ Filter Drier...
Specifications - Page 4

It's the latest in the field. Model I.D./Accessories/Compressor Air 13AJN Series Model Number Identification 13 A * 13 SEER A = AIR CONDITIONER VOLTAGE J = 208-230 SINGLE PHASE C = 200/230V-3-60 D = 460V-3-60 Y = 575V-3-60 N DESIGN SERIES N = 3RD DESIGN R-410A 18 NOMINAL COOLING CAPACITY 18 = 18,000 BTU/HR [5.28 kW] 24 = 24,000 BTU/HR [7.03 kW] 30 = 30,000 BTU/HR [8.79 kW] 36 = 36,000 ...
Specifications - Page 8

...SEER Sound Rating dB Indoor CFM [L/s] 14.00 74 900 [425] 13.50 74 925 [437] 13.50 74 1,000 [472] 13...13.50 74 1,025 [484] 14.00 74 900 [425] 14.00 74 1,050 [495] 14.50 74 975 [460] 14.50 74 875 [413] 14.00 74 1,000 [472] [ ] Designates Metric Conversions 8 Performance Data Air 13AJN Series Performance Data @ AHRI Standard Conditions-Cooling Model...50 30 (AJN) RCFL-A*...
Specifications - Page 11

...13.00 74 975 [460] 13.00 74 1,000 [472] 13.00 74 1,175 [554] 13.00 74 1,175 [554] 14.00 74 1,150 [543] [ ] Designates Metric Conversions 11 test procedures. Performance Data Air 13AJN Series Performance Data @ AHRI Standard Conditions-Cooling Model...800 [1.7] 12.00 30 (AJN) RCQD-3624(RGJF-10?ZCM?) RCQD-3624(RGJF-12?RCM?) 29,600 [8.7] 29,600 [8.7] 24,000 [7.0] 23,950 [7.0]...
Specifications - Page 12

test procedures. Performance Data Air 13AJN Series Performance Data @ AHRI Standard Conditions-Cooling Model Numbers 80°F [26.5°C] DB/67°F [19.5°C] WB Indoor Air 95°F [35°C] DB Outdoor Air Outdoor Unit 13AJN Indoor Coil and/or Air Handler Total Net Net Capacity Sensible Latent EER BTU/H [kW] BTU/H [kW] BTU/H [kW] Rev. 5/17/12...
Specifications - Page 13

... 1,025 [484] 13.50 74 1,025 [484] 13.50 74 1,000 [472] 13.50 74 1,050 [495] 13.50 74 1,025 [484] 13.50 74 1,025 [484] 13.50 74 1,000 [472] 13.50 74 1,050 [495] 13.50 74 1,025 [484] [ ] Designates Metric Conversions 13 test procedures. Performance Data Air 13AJN Series Performance Data @ AHRI Standard Conditions-Cooling Model Numbers 80°...
Specifications - Page 14

...Air 13AJN Series Performance Data @ AHRI Standard Conditions-Cooling Model Numbers 80°F [26.5°C] DB/67°F [19.5°C] WB Indoor Air 95°F [35°C] DB Outdoor Air Outdoor Unit 13AJN Indoor Coil and/or Air... combination required by D.O.E. test procedures. SEER Sound Rating dB Indoor CFM [L/s] 13.50 74 1,025 [484] 14.00 74 1,050 [495] 13.50 74 1,075 [507] 14.00...
Specifications - Page 15

...Air 13AJN Series Performance Data @ AHRI Standard Conditions-Cooling Model Numbers 80°F [26.5°C] DB/67°F [19.5°C] WB Indoor Air 95°F [35°C] DB Outdoor Air Outdoor Unit 13AJN Indoor Coil and/or Air... 11.50 36 (AJN, ACN, ADN) ...SEER Sound Rating dB Indoor CFM [L/s] 14.00 74 1,100 [519] 13.50 74 1,200 [566] 13.50 74 1,200 [566] 13.50 74 1,175 [554] 13...
Specifications - Page 16

...Air 13AJN Series Performance Data @ AHRI Standard Conditions-Cooling Model Numbers 80°F [26.5°C] DB/67°F [19.5°C] WB Indoor Air 95°F [35°C] DB Outdoor Air Outdoor Unit 13AJN Indoor Coil and/or Air... 11.50 42 (AJN, ACN, ADN) ...SEER Sound Rating dB Indoor CFM [L/s] 13.50 75 1,225 [578] 13.50 75 1,225 [578] 13.50 75 1,200 [566] 14.00 75 1,200 [566] 13...
Specifications - Page 17

test procedures. Performance Data Air 13AJN Series Performance Data @ AHRI Standard Conditions-Cooling Model Numbers 80°F [26.5°C] DB/67°F [19.5°C] WB Indoor Air 95°F [35°C] DB Outdoor Air Outdoor Unit 13AJN Indoor Coil and/or Air Handler Total Net Net Capacity Sensible Latent EER BTU/H [kW] BTU/H [kW] BTU/H [kW] Rev. 5/17/12...
Specifications - Page 18

test procedures. Performance Data Air 13AJN Series Performance Data @ AHRI Standard Conditions-Cooling Model Numbers 80°F [26.5°C] DB/67°F [19.5°C] WB Indoor Air 95°F [35°C] DB Outdoor Air Outdoor Unit 13AJN Indoor Coil and/or Air Handler Total Net Net Capacity Sensible Latent EER BTU/H [kW] BTU/H [kW] BTU/H [kW] Rev. 5/17/12...

Rheem 13AJN Reviews

Do you have an experience with the Rheem 13AJN that you would like to share?
Earn 750 points for your review!
We have not received any reviews for Rheem yet.

Popular Rheem 13AJN Search Terms

The following terms are frequently used to search for Rheem 13AJN support:

Ask a New Question
Use the box below to post a new question about Rheem 13AJN.
Manuals / Documents
Download any of our Rheem 13AJN manuals for free!

We have the following 2 documents available for the Rheem 13AJN:
  • Specifications
  • Brochure
Related Items

Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Rheem Manuals

Find free Rheem 13AJN manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Rheem Reviews

View thousands of Rheem 13AJN user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Rheem customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Rheem customer service rankings, employee comments and much more from our sister site.

Rheem Recalls

Find comprehensive Rheem recall information updated hourly on RecallOwl.com.