Use and Care
Page 2
The dryer must conform with local codes, or in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70. 2 IMPORTANT: The gas installation must be electrically grounded in accordance with local codes, or in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1/NFPA 54.
The dryer must conform with local codes, or in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70. 2 IMPORTANT: The gas installation must be electrically grounded in accordance with local codes, or in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1/NFPA 54.
Use and Care
Page 3
... this or any other flammable vapors and liquids in the vicinity of this manual must be performed by the customer, regardless of who installed the dryer. WARNING: Gas leaks cannot always be detected by : ■■ Cleaning your gas supplier. Do not use a metal foil vent. For more than... Use a heavy metal vent. The venting system attached to light any appliance. • Do not touch any electrical switch; WHAT TO DO IF YOU SMELL GAS: • Do not try to the dryer plays a big role in good air flow. ■■ Replace plastic or foil vent material with heat...
... this or any other flammable vapors and liquids in the vicinity of this manual must be performed by the customer, regardless of who installed the dryer. WARNING: Gas leaks cannot always be detected by : ■■ Cleaning your gas supplier. Do not use a metal foil vent. For more than... Use a heavy metal vent. The venting system attached to light any appliance. • Do not touch any electrical switch; WHAT TO DO IF YOU SMELL GAS: • Do not try to the dryer plays a big role in good air flow. ■■ Replace plastic or foil vent material with heat...
Use and Care
Page 6
...1. Rack Dry Washable wool items (block to remove a load from the dryer as soon as gasoline, away from the dryer as soon as sweaters and pillows without tumbling. WARNING: To reduce the risk of fire, electric shock, or injury to persons, read the IMPORTANT SAFETY INSTRUCTIONS before each ...load. This guide covers several different models. Before using your dryer has a Temperature selector, set to dry items such as it stops....
...1. Rack Dry Washable wool items (block to remove a load from the dryer as soon as gasoline, away from the dryer as soon as sweaters and pillows without tumbling. WARNING: To reduce the risk of fire, electric shock, or injury to persons, read the IMPORTANT SAFETY INSTRUCTIONS before each ...load. This guide covers several different models. Before using your dryer has a Temperature selector, set to dry items such as it stops....
Use and Care
Page 8
... open fuel supply line. 5. Make sure leveling legs are not harmful to your dryer and will be done by a qualified servicer. Changing the Drum Light (on dryer usage. Electric Dryers For power supply cord-connected dryers: 1. Turn bulb counterclockwise. Disconnect power. 8 Cleaning the Dryer Interior 1. Tumble a load of the drum and rub with a damp cloth. 3. Removing...
... open fuel supply line. 5. Make sure leveling legs are not harmful to your dryer and will be done by a qualified servicer. Changing the Drum Light (on dryer usage. Electric Dryers For power supply cord-connected dryers: 1. Turn bulb counterclockwise. Disconnect power. 8 Cleaning the Dryer Interior 1. Tumble a load of the drum and rub with a damp cloth. 3. Removing...
Use and Care
Page 9
... diameter the correct size? If the problem continues, call an electrician. ■■ For gas dryers, is the dryer level front to back and side to Automatic Drying? Electric dryers require 240-volt power supply. Check with lint? Replace the fuse or reset the circuit breaker. ... clothing is not too long or has too many turns. www.amana.com/help Dryer will not start in a room with temperature below 45ºF (7ºC)? Electric dryers use a plastic vent. Use 4" (102 mm) diameter vent material. The dryer will not run ■■ Has a household fuse blown, ...
... diameter the correct size? If the problem continues, call an electrician. ■■ For gas dryers, is the dryer level front to back and side to Automatic Drying? Electric dryers require 240-volt power supply. Check with lint? Replace the fuse or reset the circuit breaker. ... clothing is not too long or has too many turns. www.amana.com/help Dryer will not start in a room with temperature below 45ºF (7ºC)? Electric dryers use a plastic vent. Use 4" (102 mm) diameter vent material. The dryer will not run ■■ Has a household fuse blown, ...
Use and Care
Page 10
... will not transfer to a partially dried load can stain your garments. The new electric heating element may feel very warm. ■■ Was a high temperature cycle used ? Items removed before removing laundry from the dryer before each load. fits 29" (737 mm) Super Capacity, 6.5 cu. side...the load removed from the area, rewash, and dry the clothing. ■■ Is the electric dryer being dried. ■■ Is the load too large and heavy to move and install dryer. Select a lower temperature, and use an automatic drying cycle. These cycles sense the temperature or...
... will not transfer to a partially dried load can stain your garments. The new electric heating element may feel very warm. ■■ Was a high temperature cycle used ? Items removed before removing laundry from the dryer before each load. fits 29" (737 mm) Super Capacity, 6.5 cu. side...the load removed from the area, rewash, and dry the clothing. ■■ Is the electric dryer being dried. ■■ Is the load too large and heavy to move and install dryer. Select a lower temperature, and use an automatic drying cycle. These cycles sense the temperature or...
Dimension Guide
Page 1
...(12.7 cm) clearance behind the dryer for exhaust vent with product. Side view - Number of 90° turns or elbows Type of elbows. See the exhaust vent length chart that matches your dryer to the chart. ® Electric Dryer PRODUCT MODEL NUMBERS NED4500V NED5100T NED5200T NED5240T... NED5400T NED5500T NED5800T NED4800V Electrical: To supply the required three- or fourwire, single-phase, 120/240-...
...(12.7 cm) clearance behind the dryer for exhaust vent with product. Side view - Number of 90° turns or elbows Type of elbows. See the exhaust vent length chart that matches your dryer to the chart. ® Electric Dryer PRODUCT MODEL NUMBERS NED4500V NED5100T NED5200T NED5240T... NED5400T NED5500T NED5800T NED4800V Electrical: To supply the required three- or fourwire, single-phase, 120/240-...
Installation Instruction
Page 1
... superior de la puerta. All safety messages will follow instructions. Tenga listo su número de modelo completo. Canada 5 Electrical Connection - U.S.A 3 Electrical Requirements - This symbol alerts you don't immediately follow instructions. 29" (73.7 CM) ELECTRIC DRYER INSTALLATION INSTRUCTIONS INSTRUCTIONS POUR L'INSTALLATION DE LA SÉCHEUSE ÉLECTRIQUE DE 29" (73,7 CM) Table of others...
... superior de la puerta. All safety messages will follow instructions. Tenga listo su número de modelo completo. Canada 5 Electrical Connection - U.S.A 3 Electrical Requirements - This symbol alerts you don't immediately follow instructions. 29" (73.7 CM) ELECTRIC DRYER INSTALLATION INSTRUCTIONS INSTRUCTIONS POUR L'INSTALLATION DE LA SÉCHEUSE ÉLECTRIQUE DE 29" (73,7 CM) Table of others...
Installation Instruction
Page 2
... from whom you are using a power supply cord, a grounded electrical outlet located within 2 ft (61 cm) of either side of 1" (2.5 cm) under entire dryer. (If slope is greater than 1" [2.5 cm], install Extended Dryer Feet Kit, Part Number 279810.) Clothes may not tumble properly and...all parts were included. 4 leveling legs Parts needed: Check local codes, check existing electrical supply and venting and see "Electrical Requirements" and "Venting Requirements" before starting installation. At lower temperatures, the dryer might not shut off at least 4 ft (1.22 m) long. Read and follow ...
... from whom you are using a power supply cord, a grounded electrical outlet located within 2 ft (61 cm) of either side of 1" (2.5 cm) under entire dryer. (If slope is greater than 1" [2.5 cm], install Extended Dryer Feet Kit, Part Number 279810.) Clothes may not tumble properly and...all parts were included. 4 leveling legs Parts needed: Check local codes, check existing electrical supply and venting and see "Electrical Requirements" and "Venting Requirements" before starting installation. At lower temperatures, the dryer might not shut off at least 4 ft (1.22 m) long. Read and follow ...
Installation Instruction
Page 3
...is used, it is recommended that a qualified electrician determine that the electrical connection is suitable for wall, door and floor moldings. ■ Additional spacing should be at least twice as large as the dryer exhaust opening. Do not have a fuse in mobile homes to ...home installations require: ■ Metal exhaust system hardware, which is available for the exhaust vent with the National Electrical Code, ANSI/NFPA 70-latest edition and all sides of the dryer to reduce noise transfer. ■ For closet installation, with vents 3"* (7.6 cm) *Required spacing Mobile Home...
...is used, it is recommended that a qualified electrician determine that the electrical connection is suitable for wall, door and floor moldings. ■ Additional spacing should be at least twice as large as the dryer exhaust opening. Do not have a fuse in mobile homes to ...home installations require: ■ Metal exhaust system hardware, which is available for the exhaust vent with the National Electrical Code, ANSI/NFPA 70-latest edition and all sides of the dryer to reduce noise transfer. ■ For closet installation, with vents 3"* (7.6 cm) *Required spacing Mobile Home...
Installation Instruction
Page 4
...wire receptacle of NEMA Type 14-30R. If connecting by a qualified electrician. This dryer uses a cord having an equipment-grounding conductor and a grounding plug. If the dryer is installed with a 4-wire electrical supply connection, the neutral ground wire must be removed from the neutral conductor. ■...gauge solid copper wires and match a 3-wire receptacle of a neutral ground wire to the neutral conductor (white wire) within the dryer. Electrical Connection To properly install your outlet looks like this : 4-wire receptacle (14-30R) Then choose a 4-wire power supply cord with...
...wire receptacle of NEMA Type 14-30R. If connecting by a qualified electrician. This dryer uses a cord having an equipment-grounding conductor and a grounding plug. If the dryer is installed with a 4-wire electrical supply connection, the neutral ground wire must be removed from the neutral conductor. ■...gauge solid copper wires and match a 3-wire receptacle of a neutral ground wire to the neutral conductor (white wire) within the dryer. Electrical Connection To properly install your outlet looks like this : 4-wire receptacle (14-30R) Then choose a 4-wire power supply cord with...
Installation Instruction
Page 5
...-30R ■ Do not use Power Supply Cord Replacement Part Number 3394208. grounding conductor can result in the Dryer User Instructions. The cord is recommended. Electrical Shock Hazard Plug into an appropriate outlet that you are in length. If you use an extension cord. In... the outlet, have a proper outlet installed by providing a path of electric shock. Connect to whether the dryer is within reach of electric shock by a qualified electrician. Do not modify the plug provided with the dryer: if it is equipped with a qualified electrician or service representative or ...
...-30R ■ Do not use Power Supply Cord Replacement Part Number 3394208. grounding conductor can result in the Dryer User Instructions. The cord is recommended. Electrical Shock Hazard Plug into an appropriate outlet that you are in length. If you use an extension cord. In... the outlet, have a proper outlet installed by providing a path of electric shock. Connect to whether the dryer is within reach of electric shock by a qualified electrician. Do not modify the plug provided with the dryer: if it is equipped with a qualified electrician or service representative or ...
Installation Instruction
Page 7
...Wire *If local codes do not permit the use of the strain relief through the hole below terminal block opening C. Electrical Connection Options If your type of electrical connection: 4-wire (recommended) 3-wire (if 4-wire is required for mobile homes and where local codes do not permit...conduit connector B. Strain relief threads ■ Put direct wire cable through the strain relief. The strain relief should have a tight fit with the dryer cabinet and be in a horizontal position. The strain relief should have a tight fit with upturned ends F. ¾" (1.9 cm) UL listed ...
...Wire *If local codes do not permit the use of the strain relief through the hole below terminal block opening C. Electrical Connection Options If your type of electrical connection: 4-wire (recommended) 3-wire (if 4-wire is required for mobile homes and where local codes do not permit...conduit connector B. Strain relief threads ■ Put direct wire cable through the strain relief. The strain relief should have a tight fit with the dryer cabinet and be in a horizontal position. The strain relief should have a tight fit with upturned ends F. ¾" (1.9 cm) UL listed ...
Installation Instruction
Page 8
...homes and where local codes do not permit the use of power supply cord F. Direct wire cable must have completed your electrical connections. Shape ends of wires into slot of direct wire cable under center, silvercolored terminal block screw. Tighten screw. Connect... neutral ground wire and place the hooked end (hook facing right) of the neutral wire (white or center wire) of dryer rear panel. B. Center silver-colored terminal block screw C. Neutral ground wire 8 1. Strip insulation back 1" (2.5 cm). External ground conductor screw...
...homes and where local codes do not permit the use of power supply cord F. Direct wire cable must have completed your electrical connections. Shape ends of wires into slot of direct wire cable under center, silvercolored terminal block screw. Tighten screw. Connect... neutral ground wire and place the hooked end (hook facing right) of the neutral wire (white or center wire) of dryer rear panel. B. Center silver-colored terminal block screw C. Neutral ground wire 8 1. Strip insulation back 1" (2.5 cm). External ground conductor screw...
Installation Instruction
Page 9
...2. Neutral wire (white or center wire) D. ¾" (1.9 cm) UL listed strain relief E. Tighten screws. 5. You have completed your electrical connections. Insert tab of terminal block cover into slot of the terminal block. 3. Neutral wire (white or center wire) E 1.9 cm)...External ground conductor screw C. Strip insulation back 1" (2.5 cm). Neutral ground wire 4. You have completed your electrical connections. Direct wire cable must have 5 ft (1.52 m) of dryer rear panel. A B C 1. Place the hooked ends of the other wires to the center, silver-colored...
...2. Neutral wire (white or center wire) D. ¾" (1.9 cm) UL listed strain relief E. Tighten screws. 5. You have completed your electrical connections. Insert tab of terminal block cover into slot of the terminal block. 3. Neutral wire (white or center wire) E 1.9 cm)...External ground conductor screw C. Strip insulation back 1" (2.5 cm). Neutral ground wire 4. You have completed your electrical connections. Direct wire cable must have 5 ft (1.52 m) of dryer rear panel. A B C 1. Place the hooked ends of the other wires to the center, silver-colored...
Installation Instruction
Page 10
... E. ¾" (1.9 cm) UL listed strain relief F. 1. Remove center silver-colored terminal block screw. 2. Tighten screws. 4. You have completed your electrical connections. Neutral ground wire C. Grounding path determined by a qualified electrician 3. Connect a separate copper ground wire from external ground conductor screw. B C D... silver-colored terminal block screw D. Squeeze hooked ends together. Insert tab of terminal block cover into slot of dryer rear panel. Connect neutral ground wire and the neutral wire (white or center wire) of power supply cord/cable...
... E. ¾" (1.9 cm) UL listed strain relief F. 1. Remove center silver-colored terminal block screw. 2. Tighten screws. 4. You have completed your electrical connections. Neutral ground wire C. Grounding path determined by a qualified electrician 3. Connect a separate copper ground wire from external ground conductor screw. B C D... silver-colored terminal block screw D. Squeeze hooked ends together. Insert tab of terminal block cover into slot of dryer rear panel. Connect neutral ground wire and the neutral wire (white or center wire) of power supply cord/cable...
Installation Instruction
Page 15
...that you do not feel heat, cancel cycle and close the door. When the dryer has been running or "On" position. ■ Start button has been pushed firmly. ■ Dryer is plugged into an outlet and/or electrical supply is on the console and any dust. ■ There may notice a ...burning odor when the dryer is closed. 11. The odor will not start the dryer. 2. If you have not tripped. If there is ...
...that you do not feel heat, cancel cycle and close the door. When the dryer has been running or "On" position. ■ Start button has been pushed firmly. ■ Dryer is plugged into an outlet and/or electrical supply is on the console and any dust. ■ There may notice a ...burning odor when the dryer is closed. 11. The odor will not start the dryer. 2. If you have not tripped. If there is ...