PakBus NetWorking Guide
Page 3
... CR10X-PB PakBus Settings with a Keyboard Display A-1 Figures 3-1. Use the Adobe Acrobat® bookmarks tab for links to specific sections. 1. PakBus Dataloggers 9 4.1 CRBasic Dataloggers (CR800, CR850, CR1000, and CR3000 10 4.2 CR200 Series Datalogger 11 4.3 Edlog Dataloggers (CR510-PB, CR10X-PB and CR23X-PB 12 4.3.1 PakBus Settings 12 5. Network Map 5 i PakBus Networking Guide Table of Contents PDF...
... CR10X-PB PakBus Settings with a Keyboard Display A-1 Figures 3-1. Use the Adobe Acrobat® bookmarks tab for links to specific sections. 1. PakBus Dataloggers 9 4.1 CRBasic Dataloggers (CR800, CR850, CR1000, and CR3000 10 4.2 CR200 Series Datalogger 11 4.3 Edlog Dataloggers (CR510-PB, CR10X-PB and CR23X-PB 12 4.3.1 PakBus Settings 12 5. Network Map 5 i PakBus Networking Guide Table of Contents PDF...
PakBus NetWorking Guide
Page 14
.... Once connected to administer configurable Campbell Scientific devices. If the allowed neighbor list is used to the datalogger with the Device Configuration Utility, which is activated, the device will consider a neighbor on the Add Range button. PakBus Networking Guide 4.1 CRBasic Dataloggers (CR800, CR850, CR1000, and CR3000) PakBus settings for these dataloggers are entered with the Device Configuration...
.... Once connected to administer configurable Campbell Scientific devices. If the allowed neighbor list is used to the datalogger with the Device Configuration Utility, which is activated, the device will consider a neighbor on the Add Range button. PakBus Networking Guide 4.1 CRBasic Dataloggers (CR800, CR850, CR1000, and CR3000) PakBus settings for these dataloggers are entered with the Device Configuration...
CR800 and CR850 Measurement and Control Systems
Page 96
...® communications protocol. Caution Depending on the method and quality of which Preserve Settings via Program Send Instituted Datalogger OS Version / Date CR1000 16 / 11-10-08 CR800 7 / 11-10-08 CR3000 9 / 11-10-08 Campbell Scientific recommends upgrading operating systems only via program Send because: o Operating systems are specific to supporting the telecommunications link...
...® communications protocol. Caution Depending on the method and quality of which Preserve Settings via Program Send Instituted Datalogger OS Version / Date CR1000 16 / 11-10-08 CR800 7 / 11-10-08 CR3000 9 / 11-10-08 Campbell Scientific recommends upgrading operating systems only via program Send because: o Operating systems are specific to supporting the telecommunications link...
CR800 and CR850 Measurement and Control Systems
Page 123
Predefined constants include some instruction names, as well as variable or table names in a datalogger program, even if they are reserved for instruction parameters. If a predefined constant, such as "SubScan" is used as a variable in a program,...! Predefined Constants and Reserved Words _50hz _60hz Auto AutoRange AutoRangec BOOL8 CAO1 CAO2 Case Com2 Com3 Com310 ComME ComRS232 ComSDC10 ComSDC7 ComSDC8 CR1000 CR5000 CR800 CR9000X DO EVENT FLOAT hr FALSE If IX2 IEEE4 IX4 LONG IX3 msec mv1000C min mv1000R mv2_5c mv1000cR mv200 mv200cR mv20 mv20c mv250...
Predefined constants include some instruction names, as well as variable or table names in a datalogger program, even if they are reserved for instruction parameters. If a predefined constant, such as "SubScan" is used as a variable in a program,...! Predefined Constants and Reserved Words _50hz _60hz Auto AutoRange AutoRangec BOOL8 CAO1 CAO2 Case Com2 Com3 Com310 ComME ComRS232 ComSDC10 ComSDC7 ComSDC8 CR1000 CR5000 CR800 CR9000X DO EVENT FLOAT hr FALSE If IX2 IEEE4 IX4 LONG IX3 msec mv1000C min mv1000R mv2_5c mv1000cR mv200 mv200cR mv20 mv20c mv250...
CR800 and CR850 Measurement and Control Systems
Page 134
...by processing arguments that is converted to a value determined by the datalogger. Note Measurement tasks have access to measurement hardware with a simple variable or even a delay, but understand that the CR1000 operating system will not do this way, all instructions are made...datalogger uses a queuing system for processing tasks similar to allow accurate timing needed within most measurement instructions. Table 16. Measurements in the CRBasic program to avoid conflicting use of code at which they are made in a program. Other tasks, such as engaging Campbell Scientific...
...by processing arguments that is converted to a value determined by the datalogger. Note Measurement tasks have access to measurement hardware with a simple variable or even a delay, but understand that the CR1000 operating system will not do this way, all instructions are made...datalogger uses a queuing system for processing tasks similar to allow accurate timing needed within most measurement instructions. Table 16. Measurements in the CRBasic program to avoid conflicting use of code at which they are made in a program. Other tasks, such as engaging Campbell Scientific...
CR800 and CR850 Measurement and Control Systems
Page 200
...possible to be sent to include. Within the program are examples showing the use of the predefined LoggerType constant and associated predefined datalogger constants (CR800, CR1000, and CR3000). Const ProgramSpeed = 2 #If ProgramSpeed = 1 Const ScanRate = 1 Const Speed = "1 Second" #ElseIf ...compiler command line by legacy Campbell Scientific dataloggers. CRBasic Editor now features a pre-compile option that demonstrates use of conditional compilation features in . #If LoggerType = CR3000 Const SourcSerialPort = Com3 #ElseIf LoggerTypes = CR1000 Const SourcSerialPort = Com2 ...
...possible to be sent to include. Within the program are examples showing the use of the predefined LoggerType constant and associated predefined datalogger constants (CR800, CR1000, and CR3000). Const ProgramSpeed = 2 #If ProgramSpeed = 1 Const ScanRate = 1 Const Speed = "1 Second" #ElseIf ...compiler command line by legacy Campbell Scientific dataloggers. CRBasic Editor now features a pre-compile option that demonstrates use of conditional compilation features in . #If LoggerType = CR3000 Const SourcSerialPort = Com3 #ElseIf LoggerTypes = CR1000 Const SourcSerialPort = Com2 ...
CR800 and CR850 Measurement and Control Systems
Page 201
...'Main Program BeginProg 'Return the selected speed and logger type for background on the datalogger type the program is running at " & Speed & " intervals." #ElseIf LoggerType = CR800 SelectedSpeed = "CR800 running in. #If LoggerType = CR3000 'This instruction is used if the logger is...,1,mV1000,22,0,0,_50Hz,0.1,-30) #ElseIf LoggerType = CR1000 'This instruction is used if the logger is a CR1000 VoltSe(ValueRead,1,mV2500,12,0,0,_50Hz,0.1,-30) #ElseIf LoggerType = CR800 'This instruction is used if the logger is a CR800 Series VoltSe(ValueRead,1,mV2500,3,0,0,_50Hz,0.1,-30) #Else ValueRead...
...'Main Program BeginProg 'Return the selected speed and logger type for background on the datalogger type the program is running at " & Speed & " intervals." #ElseIf LoggerType = CR800 SelectedSpeed = "CR800 running in. #If LoggerType = CR3000 'This instruction is used if the logger is...,1,mV1000,22,0,0,_50Hz,0.1,-30) #ElseIf LoggerType = CR1000 'This instruction is used if the logger is a CR1000 VoltSe(ValueRead,1,mV2500,12,0,0,_50Hz,0.1,-30) #ElseIf LoggerType = CR800 'This instruction is used if the logger is a CR800 Series VoltSe(ValueRead,1,mV2500,3,0,0,_50Hz,0.1,-30) #Else ValueRead...
CR800 and CR850 Measurement and Control Systems
Page 297
...will probably induce significant error in table Pulse-Input Channels and Measurements (p. 39), all CR800 pulse-input channels can also be used, Campbell Scientific strongly encourages users to the CR800. If an external reference junction is available at www.campbellsci.com. 8.1.5 Pulse Figure Pulse... panel. The lack of an insulating wiring terminal cover and the nature of the CR1000 Datalogger Operator's Manual, which is to be measured with CRBasic instruction PulseCount(). The CR800 features two dedicated pulse-input channels, P1 through P2, and four digital I /O ...
...will probably induce significant error in table Pulse-Input Channels and Measurements (p. 39), all CR800 pulse-input channels can also be used, Campbell Scientific strongly encourages users to the CR800. If an external reference junction is available at www.campbellsci.com. 8.1.5 Pulse Figure Pulse... panel. The lack of an insulating wiring terminal cover and the nature of the CR1000 Datalogger Operator's Manual, which is to be measured with CRBasic instruction PulseCount(). The CR800 features two dedicated pulse-input channels, P1 through P2, and four digital I /O ...
CR800 and CR850 Measurement and Control Systems
Page 346
... Hello, Hello Request, Send Neighbors, Get Neighbors, and Echo are NOT encrypted. Campbell Scientific products supporting PakBus encryption include the following: • LoggerNet 4.2 • CR1000 datalogger (OS26 and newer) • CR3000 datalogger (OS26 and newer) • CR800 series dataloggers (OS26 and newer) • Device Configuration Utility (DevConfig) v. 2.04 and newer • Network Planner v. 1.6 and newer. Operation As...
... Hello, Hello Request, Send Neighbors, Get Neighbors, and Echo are NOT encrypted. Campbell Scientific products supporting PakBus encryption include the following: • LoggerNet 4.2 • CR1000 datalogger (OS26 and newer) • CR3000 datalogger (OS26 and newer) • CR800 series dataloggers (OS26 and newer) • Device Configuration Utility (DevConfig) v. 2.04 and newer • Network Planner v. 1.6 and newer. Operation As...
CR800 and CR850 Measurement and Control Systems
Page 374
... file password in the .csipasswrd file IP address of the CR800 memory drive of collections often needing frequent management. 8.6.3.7.1 Sending a File to a Datalogger A file can be sent to the CR800, open a command prompt window ("DOS window") and execute the... following form (command line parameters are described in the LoggerNet RTMC program files folder or at http://curl.haxx.se. The Curl.exe command line takes the following command, as a continuous line: curl -XPUT -v -S -T "c:\campbellsci\lib\OperatingSystems\CR1000...
... file password in the .csipasswrd file IP address of the CR800 memory drive of collections often needing frequent management. 8.6.3.7.1 Sending a File to a Datalogger A file can be sent to the CR800, open a command prompt window ("DOS window") and execute the... following form (command line parameters are described in the LoggerNet RTMC program files folder or at http://curl.haxx.se. The Curl.exe command line takes the following command, as a continuous line: curl -XPUT -v -S -T "c:\campbellsci\lib\OperatingSystems\CR1000...
CR800 and CR850 Measurement and Control Systems
Page 375
Operation *Done waiting for 100-continue Section 8.
Operation *Done waiting for 100-continue Section 8.
CR800 and CR850 Measurement and Control Systems
Page 427
... Software The calibration wizard facilitates the use with a PC running the datalogger support software. constant A connector is set up to mimic the storage areas in datalogger memory, and by which the CR800 initiates telecommunication with the CR1000 and CR800 dataloggers. A binary file is created for a datalogger is a device that as "Initiate Telecommunications." These files are set of...
... Software The calibration wizard facilitates the use with a PC running the datalogger support software. constant A connector is set up to mimic the storage areas in datalogger memory, and by which the CR800 initiates telecommunication with the CR1000 and CR800 dataloggers. A binary file is created for a datalogger is a device that as "Initiate Telecommunications." These files are set of...
CR800 and CR850 Measurement and Control Systems
Page 428
...www.campbellsci.com, for use with LoggerNet datalogger support software. constant A packet of the CR800. CPU Central processing unit. If a CR10X Older generation Campbell Scientific datalogger replaced by the CR800. CVI Communications verification interval. Section 11....Campbell Scientific Input / Output. CS I /O Terminals C1 ‐ C4 or processes utilizing these terminals. The plug at which a PakBus® device verifies the accessibility of a lamp power cord is a command‐line interpreter associated with the CR1000 and CR800 dataloggers. Refer to the datalogger...
...www.campbellsci.com, for use with LoggerNet datalogger support software. constant A packet of the CR800. CPU Central processing unit. If a CR10X Older generation Campbell Scientific datalogger replaced by the CR800. CVI Communications verification interval. Section 11....Campbell Scientific Input / Output. CS I /O Terminals C1 ‐ C4 or processes utilizing these terminals. The plug at which a PakBus® device verifies the accessibility of a lamp power cord is a command‐line interpreter associated with the CR1000 and CR800 dataloggers. Refer to the datalogger...
CR800 and CR850 Measurement and Control Systems
Page 540
... Covers Datalogger CR800 CR1000 CR3000 Terminal-Strip Cover Part Number No cover available 17324 18359 F.3 Cameras A camera can be an effective data gathering device. Images can be stored automatically to improve thermocouple measurements. Campbell Scientific cameras are... F.2.6 Terminal-Strip Covers Terminal strips cover and insulate input terminals to a Campbell Scientific datalogger and transmitted over a variety of Campbell Scientific telecommunications devices. Other Campbell Scientific Products 4WHB10K 4WPB100 4WPB1K 10-kΩ, four-wire, half-bridge TIM module 100...
... Covers Datalogger CR800 CR1000 CR3000 Terminal-Strip Cover Part Number No cover available 17324 18359 F.3 Cameras A camera can be an effective data gathering device. Images can be stored automatically to improve thermocouple measurements. Campbell Scientific cameras are... F.2.6 Terminal-Strip Covers Terminal strips cover and insulate input terminals to a Campbell Scientific datalogger and transmitted over a variety of Campbell Scientific telecommunications devices. Other Campbell Scientific Products 4WHB10K 4WPB100 4WPB1K 10-kΩ, four-wire, half-bridge TIM module 100...
CR800 and CR850 Measurement and Control Systems
Page 545
... cable, nine-pin female to nine-pin male SRM-5A with the CR800 datalogger. Model Compatible Keyboard Display CR800 CR1000KD (p. 428), CD100 (p. 427) CR850 CR1000 CR3000 Integrated keyboard display, CR1000KD, CD100 CR1000KD, CD100 Integrated keyboard display F.8.2 Direct Serial Communications Devices Table 148. Other Campbell Scientific Products F.8 Telecommunications Products Many telecommunications devices are either integrated into the...
... cable, nine-pin female to nine-pin male SRM-5A with the CR800 datalogger. Model Compatible Keyboard Display CR800 CR1000KD (p. 428), CD100 (p. 427) CR850 CR1000 CR3000 Integrated keyboard display, CR1000KD, CD100 CR1000KD, CD100 Integrated keyboard display F.8.2 Direct Serial Communications Devices Table 148. Other Campbell Scientific Products F.8 Telecommunications Products Many telecommunications devices are either integrated into the...