TE525, TE525WS, and TE525MM Texas Electronics Rain Gages
Page 3
... locations, Campbell will return such products by Campbell Scientific, Inc. ("Campbell") to be the sole and exclusive remedy under this warranty is part of Entry) INCOTERM® 2010, prepaid. Campbell will return such products best way CIP (Port of Campbell's product warranty. To all costs of America. The warranty for installation services performed by Campbell such as programming to customer specifications, electrical connections to...
... locations, Campbell will return such products by Campbell Scientific, Inc. ("Campbell") to be the sole and exclusive remedy under this warranty is part of Entry) INCOTERM® 2010, prepaid. Campbell will return such products best way CIP (Port of Campbell's product warranty. To all costs of America. The warranty for installation services performed by Campbell such as programming to customer specifications, electrical connections to...
TE525, TE525WS, and TE525MM Texas Electronics Rain Gages
Page 4
.... If the form is : CAMPBELL SCIENTIFIC, INC. directly. Campbell Scientific's shipping address is not received within their territories. Campbell Scientific reserves the right to refuse service on the outside of the problem, an RMA number will be returned to contaminants that were exposed to the customer at www.campbellsci.com/repair. To obtain a Returned Materials Authorization (RMA), contact CAMPBELL SCIENTIFIC, INC., phone (435) 227-9000...
.... If the form is : CAMPBELL SCIENTIFIC, INC. directly. Campbell Scientific's shipping address is not received within their territories. Campbell Scientific reserves the right to refuse service on the outside of the problem, an RMA number will be returned to contaminants that were exposed to the customer at www.campbellsci.com/repair. To obtain a Returned Materials Authorization (RMA), contact CAMPBELL SCIENTIFIC, INC., phone (435) 227-9000...
TE525, TE525WS, and TE525MM Texas Electronics Rain Gages
Page 5
Table of Contents PDF viewers: These page numbers refer to Program Datalogger and Generate Wiring Diagram ....4 5. Cautionary Statements 1 3. Overview 7 5.1 Wind Screen 7 5.2 Snowfall Adapter 7 6. Troubleshooting 12 9. Initial Inspection 1 3.1 Ships With 2 4. Introduction 1 2. Specifications 8 7. Operation 9 7.1 Wiring 9 7.2 Datalogger Programming 10 7.2.1 Pulse Count Example Programs 11 7.2.1.1 CR1000 Example Program 11 7.2.1.2 CR200(X) Series Example Program 11 7.2.2 Control Port Example 12 7.2.2.1 CR1000 Example Program 12 8. Maintenance 12 Appendix A. Edlog ...
Table of Contents PDF viewers: These page numbers refer to Program Datalogger and Generate Wiring Diagram ....4 5. Cautionary Statements 1 3. Overview 7 5.1 Wind Screen 7 5.2 Snowfall Adapter 7 6. Troubleshooting 12 9. Initial Inspection 1 3.1 Ships With 2 4. Introduction 1 2. Specifications 8 7. Operation 9 7.1 Wiring 9 7.2 Datalogger Programming 10 7.2.1 Pulse Count Example Programs 11 7.2.1.1 CR1000 Example Program 11 7.2.1.2 CR200(X) Series Example Program 11 7.2.2 Control Port Example 12 7.2.2.1 CR1000 Example Program 12 8. Maintenance 12 Appendix A. Edlog ...
TE525, TE525WS, and TE525MM Texas Electronics Rain Gages
Page 6
Multipliers for Control Port Input 9 7-3. Wiring for Rain Measurement 10 ii Table of Contents Figures 4-1. 4-2. 7-1. Wiring for Pulse Channel Input 9 7-2. TE525 Tipping Bucket Rain Gage 3 Pedestal base options 3 Rain Gage Schematic 10 Tables 7-1.
Multipliers for Control Port Input 9 7-3. Wiring for Rain Measurement 10 ii Table of Contents Figures 4-1. 4-2. 7-1. Wiring for Pulse Channel Input 9 7-2. TE525 Tipping Bucket Rain Gage 3 Pedestal base options 3 Rain Gage Schematic 10 Tables 7-1.
TE525, TE525WS, and TE525MM Texas Electronics Rain Gages
Page 7
... received. 1 This compound was chosen for field calibration check and factory calibration. • Debris filters, funnel, and bucket reservoirs should not require field calibration. However, this information against the shipping documentation (see Section 3.1, Ships With). Check this jacket will pass FMVSS302. Refer to Section 9, Maintenance, for its use inside buildings. 3. Contact Campbell Scientific about any discrepancies. • The model number and cable...
... received. 1 This compound was chosen for field calibration check and factory calibration. • Debris filters, funnel, and bucket reservoirs should not require field calibration. However, this information against the shipping documentation (see Section 3.1, Ships With). Check this jacket will pass FMVSS302. Refer to Section 9, Maintenance, for its use inside buildings. 3. Contact Campbell Scientific about any discrepancies. • The model number and cable...
TE525, TE525WS, and TE525MM Texas Electronics Rain Gages
Page 8
... gage should be 2 to 4 times the height of the obstruction. • The pipe used to get it . Level the rain gage after mounting it as vertical as possible. ...mounting the TE525 rain gage. The distance should be vertical. Replace the funnel and seat it completely when the installation is complete. 4.2 Mounting The CM300-series mounting poles provide a stainless steel 1.5 IPS vertical pole for the CM300, CM305, and CM310 models... Please review Section 7, Operation, for wiring, CRBasic programming, and Edlog programming. 4.1 Siting The rain gage should be mounted in the center. 2
... gage should be 2 to 4 times the height of the obstruction. • The pipe used to get it . Level the rain gage after mounting it as vertical as possible. ...mounting the TE525 rain gage. The distance should be vertical. Replace the funnel and seat it completely when the installation is complete. 4.2 Mounting The CM300-series mounting poles provide a stainless steel 1.5 IPS vertical pole for the CM300, CM305, and CM310 models... Please review Section 7, Operation, for wiring, CRBasic programming, and Edlog programming. 4.1 Siting The rain gage should be mounted in the center. 2
TE525, TE525WS, and TE525MM Texas Electronics Rain Gages
Page 10
TE525 Tipping Bucket Rain Gage 4.3 Use SCWin to Program Datalogger and Generate Wiring Diagram The simplest method for the TE525/TE525WS. Select the Datalogger and enter the Scan Interval. 4 Open Short Cut and click on New Program. 2. NOTE This section shows Short Cut's programming for programming the datalogger to measure the tipping bucket rain gages is done similarly. 1. The TE52MM is to use Campbell Scientific's SCWin Program Generator (Short Cut).
TE525 Tipping Bucket Rain Gage 4.3 Use SCWin to Program Datalogger and Generate Wiring Diagram The simplest method for the TE525/TE525WS. Select the Datalogger and enter the Scan Interval. 4 Open Short Cut and click on New Program. 2. NOTE This section shows Short Cut's programming for programming the datalogger to measure the tipping bucket rain gages is done similarly. 1. The TE52MM is to use Campbell Scientific's SCWin Program Generator (Short Cut).
TE525, TE525WS, and TE525MM Texas Electronics Rain Gages
Page 11
After entering the information, click on OK, and then select Next. 5 Select TE525/TE525WS Rain Gauge, and select the right arrow (in center of screen) to add it to be measured, and then select Next. 4. TE525 Tipping Bucket Rain Gage 3. Define the name of sensors to the list of the public variable and the measurement units.
After entering the information, click on OK, and then select Next. 5 Select TE525/TE525WS Rain Gauge, and select the right arrow (in center of screen) to add it to be measured, and then select Next. 4. TE525 Tipping Bucket Rain Gage 3. Define the name of sensors to the list of the public variable and the measurement units.
TE525, TE525WS, and TE525MM Texas Electronics Rain Gages
Page 12
In the Confirm window, click Yes to download the program to the wiring diagram generated by Short Cut. 6 TE525 Tipping Bucket Rain Gage 5. Choose the Output and then select Finish. 6. In the Save As window, enter an appropriate file name and select Save. 7. Click on Wiring Diagram and wire according to the datalogger. 8.
In the Confirm window, click Yes to download the program to the wiring diagram generated by Short Cut. 6 TE525 Tipping Bucket Rain Gage 5. Choose the Output and then select Finish. 6. In the Save As window, enter an appropriate file name and select Save. 7. Click on Wiring Diagram and wire according to the datalogger. 8.
TE525, TE525WS, and TE525MM Texas Electronics Rain Gages
Page 13
... -L after the model number indicates the cable length is not available for siting information and the installation procedure. 7 However, both the TE525 and TE525MM can terminate in a wireless sensor network. This wind screen consists of snow. The CS705 cannot be converted to a CWS900 Wireless Sensor Interface (option -CWS). Refer to the CS705 manual for the TE525MM. 5.1 Wind Screen Campbell Scientific offers the 260...
... -L after the model number indicates the cable length is not available for siting information and the installation procedure. 7 However, both the TE525 and TE525MM can terminate in a wireless sensor network. This wind screen consists of snow. The CS705 cannot be converted to a CWS900 Wireless Sensor Interface (option -CWS). Refer to the CS705 manual for the TE525MM. 5.1 Wind Screen Campbell Scientific offers the 260...
TE525, TE525WS, and TE525MM Texas Electronics Rain Gages
Page 14
... 6. Specifications Features: • High precision • Compatible with the CS705 Snowfall Adapter. Compatible Dataloggers: CR200(X)-series CR800 series CR1000 CR3000 CR5000 CR9000X CR510 CR500 CR10(X) CR23X CR7 21X Sensor Type Switch Ratings Bucket Material Funnel Collector Material Screen Material Locking Snap Ring Material Operating Temperature Resolution Volume per Tip Rainfall per Tip Accuracy Knife Edge Funnel Collector Diameter TE525 TE525WS...
... 6. Specifications Features: • High precision • Compatible with the CS705 Snowfall Adapter. Compatible Dataloggers: CR200(X)-series CR800 series CR1000 CR3000 CR5000 CR9000X CR510 CR500 CR10(X) CR23X CR7 21X Sensor Type Switch Ratings Bucket Material Funnel Collector Material Screen Material Locking Snap Ring Material Operating Temperature Resolution Volume per Tip Rainfall per Tip Accuracy Knife Edge Funnel Collector Diameter TE525 TE525WS...
TE525, TE525WS, and TE525MM Texas Electronics Rain Gages
Page 15
... CR510 CR10X CR23X Black Signal Control Port C2/P3 Control Port Control Port White Signal Return 5 V 5 V 5 V 5 V Clear Shield G 9 Operation 7.1 Wiring When Short Cut is used , the return from the rain gage switch must be wired to a datalogger's pulse channel (see TABLE 7-1). When a control port is typically wired to the channels shown on some of counting switch closures on the wiring diagram created by Short Cut. Height Tipping Bucket Weight Cable Cable Weight TE525 Tipping...
... CR510 CR10X CR23X Black Signal Control Port C2/P3 Control Port Control Port White Signal Return 5 V 5 V 5 V 5 V Clear Shield G 9 Operation 7.1 Wiring When Short Cut is used , the return from the rain gage switch must be wired to a datalogger's pulse channel (see TABLE 7-1). When a control port is typically wired to the channels shown on some of counting switch closures on the wiring diagram created by Short Cut. Height Tipping Bucket Weight Cable Cable Weight TE525 Tipping...
TE525, TE525WS, and TE525MM Texas Electronics Rain Gages
Page 16
... The volume of control port inputs with an eight inch funnel.) 10 Black White Clear 100 Ω FIGURE 7-1. A 100 Ω resistor is the same. The multiplier used to cause a tip in the TE525 and the TE525MM is connected in TABLE 7-3. (The CS705 will not install directly on the TE525MM; Choose switch closure (code 2) for users who write their own programs. A datalogger program to measure...
... The volume of control port inputs with an eight inch funnel.) 10 Black White Clear 100 Ω FIGURE 7-1. A 100 Ω resistor is the same. The multiplier used to cause a tip in the TE525 and the TE525MM is connected in TABLE 7-3. (The CS705 will not install directly on the TE525MM; Choose switch closure (code 2) for users who write their own programs. A datalogger program to measure...
TE525, TE525WS, and TE525MM Texas Electronics Rain Gages
Page 17
... Rain Gage 7.2.1 Pulse Count Example Programs The following example programs use a pulse channel to specify the pulse module's slot. 7.2.1.1 CR1000 Example Program 'CR1000 'TE525/TE525WS & TE525MM sample program Public Rain_mm Units Rain_mm=mm DataTable(Rain,True,-1) DataInterval(0,60,Min,0) Totalize(1,Rain_mm,FP2,0) EndTable BeginProg Scan(1,Sec,1,0) 'For TE525MM Rain Gage, use multiplier of 0.1 in PulseCount instruction PulseCount(Rain_mm,1,1,2,0,0.254,0) CallTable(Rain...
... Rain Gage 7.2.1 Pulse Count Example Programs The following example programs use a pulse channel to specify the pulse module's slot. 7.2.1.1 CR1000 Example Program 'CR1000 'TE525/TE525WS & TE525MM sample program Public Rain_mm Units Rain_mm=mm DataTable(Rain,True,-1) DataInterval(0,60,Min,0) Totalize(1,Rain_mm,FP2,0) EndTable BeginProg Scan(1,Sec,1,0) 'For TE525MM Rain Gage, use multiplier of 0.1 in PulseCount instruction PulseCount(Rain_mm,1,1,2,0,0.254,0) CallTable(Rain...
TE525, TE525WS, and TE525MM Texas Electronics Rain Gages
Page 18
... Units Rain_mm=mm DataTable (Rain,True,-1) DataInterval (0,60,Min,0) Totalize (1,Rain_mm,FP2,0) EndTable 'Main Program BeginProg Scan (1,Sec,1,0) 'For TE525MM Rain Gage use an ohm meter to less than an ohm when the bucket is advised every 12 months. A different multiplier would be kept clean. The following calibration check is balanced. 9. TE525 Tipping Bucket Rain Gage 7.2.2 Control Port...
... Units Rain_mm=mm DataTable (Rain,True,-1) DataInterval (0,60,Min,0) Totalize (1,Rain_mm,FP2,0) EndTable 'Main Program BeginProg Scan (1,Sec,1,0) 'For TE525MM Rain Gage use an ohm meter to less than an ohm when the bucket is advised every 12 months. A different multiplier would be kept clean. The following calibration check is balanced. 9. TE525 Tipping Bucket Rain Gage 7.2.2 Control Port...
TE525, TE525WS, and TE525MM Texas Electronics Rain Gages
Page 19
... oz. Adjust both screws causes a 2% to the large center drain hole. counter clockwise rotation decreases the number of manual). 13 TE525 Tipping Bucket Rain Gage (3) Place the can in the can . (A 16 oz. of water. One half turn of both screws the same number of the top may be used for a rough field calibration. An exact volume will...
... oz. Adjust both screws causes a 2% to the large center drain hole. counter clockwise rotation decreases the number of manual). 13 TE525 Tipping Bucket Rain Gage (3) Place the can in the can . (A 16 oz. of water. One half turn of both screws the same number of the top may be used for a rough field calibration. An exact volume will...
TE525, TE525WS, and TE525MM Texas Electronics Rain Gages
Page 21
... the Pulse (P3) instruction to specify the slot that the pulse card is in. ;{CR10X} *Table 1 Program 01: 1.0000 Execution Interval (seconds) 1: Pulse (P3) 1: 1 2: 1 3: 2 4: 3 5: 0.254 6: 0 Reps Pulse Channel 1 Switch Closure, All Counts Loc [ Rain_mm ] Multiplier Offset 2: If time is (P92) 1: 0 2: 60 3: 10 Minutes (Seconds --) into a Interval (same units as above) Set Output Flag High (Flag 0) 3: Set Active Storage Area (P80...
... the Pulse (P3) instruction to specify the slot that the pulse card is in. ;{CR10X} *Table 1 Program 01: 1.0000 Execution Interval (seconds) 1: Pulse (P3) 1: 1 2: 1 3: 2 4: 3 5: 0.254 6: 0 Reps Pulse Channel 1 Switch Closure, All Counts Loc [ Rain_mm ] Multiplier Offset 2: If time is (P92) 1: 0 2: 60 3: 10 Minutes (Seconds --) into a Interval (same units as above) Set Output Flag High (Flag 0) 3: Set Active Storage Area (P80...
TE525, TE525WS, and TE525MM Texas Electronics Rain Gages
Page 22
... section should be entered (TABLE 7-3) for other units. ;{CR10X} ; *Table 1 Program 01: 1 Execution Interval (seconds) 1: Pulse (P3) 1: 1 2: 8 3: 2 4: 1 5: .254 6: 0 Reps Control Port 8 (switch closure only) Switch Closure, All Counts Loc [ Rain_mm ] Multiplier Offset ;Black wire connect to C8 2: If time is (P92) 1: 0 2: 60 3: 10 Minutes (Seconds --) into a Interval (same units as above) Set Output Flag High (Flag 0) 3: Set Active Storage Area (P80) 1: 1 Final Storage Area...
... section should be entered (TABLE 7-3) for other units. ;{CR10X} ; *Table 1 Program 01: 1 Execution Interval (seconds) 1: Pulse (P3) 1: 1 2: 8 3: 2 4: 1 5: .254 6: 0 Reps Control Port 8 (switch closure only) Switch Closure, All Counts Loc [ Rain_mm ] Multiplier Offset ;Black wire connect to C8 2: If time is (P92) 1: 0 2: 60 3: 10 Minutes (Seconds --) into a Interval (same units as above) Set Output Flag High (Flag 0) 3: Set Active Storage Area (P80) 1: 1 Final Storage Area...