... in Cisco 12000 series routers. Cisco 12000 Series Router SIP and SPA Hardware Installation Guide 1-2 Release 12.0(32)SY1, OL-8831-01, Rev. Note References to the installation and configuration guide for information about power management. For additional information, refer to line cards in the chassis. The chassis power supply configuration may cause limitations on the router switch fabric...
... in Cisco 12000 series routers. Cisco 12000 Series Router SIP and SPA Hardware Installation Guide 1-2 Release 12.0(32)SY1, OL-8831-01, Rev. Note References to the installation and configuration guide for information about power management. For additional information, refer to line cards in the chassis. The chassis power supply configuration may cause limitations on the router switch fabric...
Hardware Installation Guide
Page 54
...Pinout, RJ-45 Connection to work with straight-through and crossover Ethernet cables. 1-Port 10-Gigabit Ethernet SPA Overview Chapter 2 Overview: Cisco 12000 Series Router Shared Port Adapters Note Referring to the RJ-45 pinout in the 8-Port FastEthernet SPA. Depending on your RJ-45 interface cabling ... SPA supports automatic MDI/MDIX crossover at all speeds of operation allowing the SPA to a Hub or Repeater Hub or LAN switch 3 TxD+ 6 TxD- Common-mode termination reduces the contributions to electromagnetic interference (EMI) and susceptibility to common-mode sources. Ethernet port 3 RxD...
...Pinout, RJ-45 Connection to work with straight-through and crossover Ethernet cables. 1-Port 10-Gigabit Ethernet SPA Overview Chapter 2 Overview: Cisco 12000 Series Router Shared Port Adapters Note Referring to the RJ-45 pinout in the 8-Port FastEthernet SPA. Depending on your RJ-45 interface cabling ... SPA supports automatic MDI/MDIX crossover at all speeds of operation allowing the SPA to a Hub or Repeater Hub or LAN switch 3 TxD+ 6 TxD- Common-mode termination reduces the contributions to electromagnetic interference (EMI) and susceptibility to common-mode sources. Ethernet port 3 RxD...
Hardware Installation Guide
Page 60
... IEEE 802.3z 1000BASE-LX standard. The minimum cable distance for the SFP-GE-S is not intended to be installed on various switch and router products. SFP-GE-Z Modules The 1000BASE-ZX (extended wavelength) module operates on 62.5/125um MMF. The 1000BASE-ZX module... Without attenuators, the minimum link distance for example, building backbones, or horizontal cabling). 2-Port Gigabit Ethernet SPA Overview Chapter 2 Overview: Cisco 12000 Series Router Shared Port Adapters SFP-GE-S Modules The 1000BASE-SX (short wavelength) module operates on standard multimode fiber-optic link spans of up...
... IEEE 802.3z 1000BASE-LX standard. The minimum cable distance for the SFP-GE-S is not intended to be installed on various switch and router products. SFP-GE-Z Modules The 1000BASE-ZX (extended wavelength) module operates on 62.5/125um MMF. The 1000BASE-ZX module... Without attenuators, the minimum link distance for example, building backbones, or horizontal cabling). 2-Port Gigabit Ethernet SPA Overview Chapter 2 Overview: Cisco 12000 Series Router Shared Port Adapters SFP-GE-S Modules The 1000BASE-SX (short wavelength) module operates on standard multimode fiber-optic link spans of up...
Hardware Installation Guide
Page 64
... their higher optical quality allows them to high-end workstations and between the fiber-optic cable plant and the receiving port on various switch and router products. SFP Module Cabling and Connection Equipment Table 2-20 provides cabling specifications for the SFP-GE-Z is 328 feet (100...minimum link distance for the SFP modules that all SFP ports have LC-type connectors. 5-Port Gigabit Ethernet SPA Overview Chapter 2 Overview: Cisco 12000 Series Router Shared Port Adapters SFP-GE-L Modules The 1000BASE-LX/LH (long-wavelength/long-haul) module interfaces fully comply with an 8-dB ...
... their higher optical quality allows them to high-end workstations and between the fiber-optic cable plant and the receiving port on various switch and router products. SFP Module Cabling and Connection Equipment Table 2-20 provides cabling specifications for the SFP-GE-Z is 328 feet (100...minimum link distance for the SFP modules that all SFP ports have LC-type connectors. 5-Port Gigabit Ethernet SPA Overview Chapter 2 Overview: Cisco 12000 Series Router Shared Port Adapters SFP-GE-L Modules The 1000BASE-LX/LH (long-wavelength/long-haul) module interfaces fully comply with an 8-dB ...
Hardware Installation Guide
Page 68
...3.1 miles (5 km) specified in the standard. The SFP-GE-T maximum cabling distance is 24.9 miles (40 km). 2-26 Cisco 12000 Series Router SIP and SPA Hardware Installation Guide Release 12.0(32)SY1, OL-8831-01, Rev. SFP Module Cabling and Connection Equipment Table ...switch and router products. Link spans of single-mode fiber are possible using premium single-mode fiber or dispersion-shifted single-mode fiber (premium single-mode fiber has a lower attenuation per unit length than ordinary single-mode fiber; 10-Port Gigabit Ethernet SPA Overview Chapter 2 Overview: Cisco 12000 Series...
...3.1 miles (5 km) specified in the standard. The SFP-GE-T maximum cabling distance is 24.9 miles (40 km). 2-26 Cisco 12000 Series Router SIP and SPA Hardware Installation Guide Release 12.0(32)SY1, OL-8831-01, Rev. SFP Module Cabling and Connection Equipment Table ...switch and router products. Link spans of single-mode fiber are possible using premium single-mode fiber or dispersion-shifted single-mode fiber (premium single-mode fiber has a lower attenuation per unit length than ordinary single-mode fiber; 10-Port Gigabit Ethernet SPA Overview Chapter 2 Overview: Cisco 12000 Series...
Hardware Installation Guide
Page 96
G6, July 19, 2007 Cisco 12000 Series Router SIP and SPA Hardware Installation Guide 3-6 Release 12.0(32)SY1, OL-8831-01, Rev. Safety Guidelines Chapter 3 Preparing to Install a SPA Interface Processor or a Shared Port Adapter Electrical Equipment Guidelines Follow these basic guidelines when working with any electrical equipment: • Before beginning any procedures requiring access to the chassis interior, locate the emergency power-off switch for the room in which you are working. • Disconnect all power and external cables before moving a chassis.
G6, July 19, 2007 Cisco 12000 Series Router SIP and SPA Hardware Installation Guide 3-6 Release 12.0(32)SY1, OL-8831-01, Rev. Safety Guidelines Chapter 3 Preparing to Install a SPA Interface Processor or a Shared Port Adapter Electrical Equipment Guidelines Follow these basic guidelines when working with any electrical equipment: • Before beginning any procedures requiring access to the chassis interior, locate the emergency power-off switch for the room in which you are working. • Disconnect all power and external cables before moving a chassis.
Hardware Installation Guide
Page 107
...on the Cisco 12000 series router. G6, July 19, 2007 This chapter describes how to install a SPA in a slot that is not in use , you begin installation, read "Preparing to electrostatic discharge (ESD) damage. Before you must fill the empty slot to allow the router or switch to ... to Install a SPA Interface Processor or a Shared Port Adapter" for a list of parts and tools required for installation. G6, July 19, 2007 Cisco 12000 Series Router SIP and SPA Hardware Installation Guide 5-1 Figure 5-1 Handling a SPA Metal carrier Printed circuit board H6420 Release 12.0(32)SY1, OL-8831-01, ...
...on the Cisco 12000 series router. G6, July 19, 2007 This chapter describes how to install a SPA in a slot that is not in use , you begin installation, read "Preparing to electrostatic discharge (ESD) damage. Before you must fill the empty slot to allow the router or switch to ... to Install a SPA Interface Processor or a Shared Port Adapter" for a list of parts and tools required for installation. G6, July 19, 2007 Cisco 12000 Series Router SIP and SPA Hardware Installation Guide 5-1 Figure 5-1 Handling a SPA Metal carrier Printed circuit board H6420 Release 12.0(32)SY1, OL-8831-01, ...
Hardware Installation Guide
Page 115
... in the empty subslot to allow the router or switch to conform to electromagnetic interference (EMI) emissions requirements and to 10.1.1.60, timeout is active (powered on), and repeat the ping command. G6, July 19, 2007 Cisco 12000 Series Router SIP and SPA Hardware Installation Guide 5-9 Sending...pos 2/3/0 Line status and data link protocol status for a particular SPA port. Table 5-3 show Commands to fill an unused SPA subslot. Cisco IOS software version, names and sources of Information Provided Example Network link status, register contents, and controller chip errors. When a SPA ...
... in the empty subslot to allow the router or switch to conform to electromagnetic interference (EMI) emissions requirements and to 10.1.1.60, timeout is active (powered on), and repeat the ping command. G6, July 19, 2007 Cisco 12000 Series Router SIP and SPA Hardware Installation Guide 5-9 Sending...pos 2/3/0 Line status and data link protocol status for a particular SPA port. Table 5-3 show Commands to fill an unused SPA subslot. Cisco IOS software version, names and sources of Information Provided Example Network link status, register contents, and controller chip errors. When a SPA ...
Hardware Installation Guide
Page 116
... Cable-Management Brackets Chapter 5 Installing and Removing a Shared Port Adapter SPA Cable-Management Brackets SPAs are installed. 5-10 Cisco 12000 Series Router SIP and SPA Hardware Installation Guide Release 12.0(32)SY1, OL-8831-01, Rev. Figure 5-3 SPA Cable-Management... 1 2 LINK LINK 3 4 LINK 7600-MSC-600 0 3 STATUS MODULAR SERVICES CARD 2 C/A 0 A/L C/A 0 A/L C/A 0 A/L C/A 0 A/L RESET ACTIVE TX RX CARRAILEARRM RX TX PORT 1 ACTIVE TX RX CARRAILEARRM RX TX PORT 2 STATUS SPA-4XOC3-ATM Switch 100% Load PORT 1 1% LINK ACTIVE TX RX CARRAILEARRM RX TX PORT...
... Cable-Management Brackets Chapter 5 Installing and Removing a Shared Port Adapter SPA Cable-Management Brackets SPAs are installed. 5-10 Cisco 12000 Series Router SIP and SPA Hardware Installation Guide Release 12.0(32)SY1, OL-8831-01, Rev. Figure 5-3 SPA Cable-Management... 1 2 LINK LINK 3 4 LINK 7600-MSC-600 0 3 STATUS MODULAR SERVICES CARD 2 C/A 0 A/L C/A 0 A/L C/A 0 A/L C/A 0 A/L RESET ACTIVE TX RX CARRAILEARRM RX TX PORT 1 ACTIVE TX RX CARRAILEARRM RX TX PORT 2 STATUS SPA-4XOC3-ATM Switch 100% Load PORT 1 1% LINK ACTIVE TX RX CARRAILEARRM RX TX PORT...
Hardware Installation Guide
Page 122
...to reset and download the MBus and fabric downloader software modules before attempting to a fabric ping request from the primary RP over the switch fabric. Cisco 12000 Series Router SIP and SPA Hardware Installation Guide 6-6 Release 12.0(32)SY1, OL-8831-01, Rev. They are caused by a bad ...connection to the MBus or switching fabric. Some errors point to a SIP, you receive any problems that should be displayed as RUN IOS. For example, ...
...to reset and download the MBus and fabric downloader software modules before attempting to a fabric ping request from the primary RP over the switch fabric. Cisco 12000 Series Router SIP and SPA Hardware Installation Guide 6-6 Release 12.0(32)SY1, OL-8831-01, Rev. They are caused by a bad ...connection to the MBus or switching fabric. Some errors point to a SIP, you receive any problems that should be displayed as RUN IOS. For example, ...