Specifications
Page 1
Spec Sheet Cisco UCS B200 M2 Blade Server CISCO SYSTEMS 170 WEST TASMAN DR. SAN JOSE, CA, 95134 WWW.CISCO.COM PUBLICATION HISTORY REV A.1 MARCH 9, 2012
Spec Sheet Cisco UCS B200 M2 Blade Server CISCO SYSTEMS 170 WEST TASMAN DR. SAN JOSE, CA, 95134 WWW.CISCO.COM PUBLICATION HISTORY REV A.1 MARCH 9, 2012
Specifications
Page 2
... HARD DISK DRIVES or SOLID STATE DRIVES 14 STEP 5 CHOOSE A PCIe MEZZANINE CARD 15 STEP 6 CHOOSE OPERATING SYSTEM 16 STEP 7 CHOOSE OPERATING SYSTEM MEDIA KIT 19 STEP 8 CHOOSE OPTIONAL VALUE-ADDED SOFTWARE 20 STEP 9 CHOOSE SERVICE and SUPPORT LEVEL 21 ORDER ...OPTIONAL KVM CABLE 25 SUPPLEMENTAL MATERIAL 26 Motherboard 26 DIMM and CPU Layout 26 Memory Population Recommendations 27 TECHNICAL SPECIFICATIONS 29 Dimensions and Weight 29 Power Specifications 29 Cisco...
... HARD DISK DRIVES or SOLID STATE DRIVES 14 STEP 5 CHOOSE A PCIe MEZZANINE CARD 15 STEP 6 CHOOSE OPERATING SYSTEM 16 STEP 7 CHOOSE OPERATING SYSTEM MEDIA KIT 19 STEP 8 CHOOSE OPTIONAL VALUE-ADDED SOFTWARE 20 STEP 9 CHOOSE SERVICE and SUPPORT LEVEL 21 ORDER ...OPTIONAL KVM CABLE 25 SUPPLEMENTAL MATERIAL 26 Motherboard 26 DIMM and CPU Layout 26 Memory Population Recommendations 27 TECHNICAL SPECIFICATIONS 29 Dimensions and Weight 29 Power Specifications 29 Cisco...
Specifications
Page 5
... Management Controller (CIMC) GUI or CLI interface enables you to monitor the server inventory, health, and system event logs. Cisco UCS B200 M2 Blade Server 5 Details about how to configure the server for a particular feature or capability (for registered DIMMs (up to... Memory Expansion slots Storage controller Internal storage devices Video Interfaces Power subsystem Fans Integrated management processor Description The B200 M2 Blade Server mounts in a Cisco UCS 5100-series chassis Either 1 or 2 Intel® Xeon® 5500 or 5600 series processors Intel® 5500 chipset 12 slots for...
... Management Controller (CIMC) GUI or CLI interface enables you to monitor the server inventory, health, and system event logs. Cisco UCS B200 M2 Blade Server 5 Details about how to configure the server for a particular feature or capability (for registered DIMMs (up to... Memory Expansion slots Storage controller Internal storage devices Video Interfaces Power subsystem Fans Integrated management processor Description The B200 M2 Blade Server mounts in a Cisco UCS 5100-series chassis Either 1 or 2 Intel® Xeon® 5500 or 5600 series processors Intel® 5500 chipset 12 slots for...
Specifications
Page 6
CONFIGURING the SERVER CONFIGURING the SERVER Follow these steps to configure the Cisco UCS B200 Blade Server: ■ STEP 1 VERIFY BASE SKU, page 7 ■ STEP 2 CHOOSE CPU(S), page 8 ■ STEP 3 CHOOSE MEMORY, page 10 ■ STEP 4 CHOOSE HARD ...DISK DRIVES or SOLID STATE DRIVES, page 14 ■ STEP 5 CHOOSE A PCIe MEZZANINE CARD, page 15 ■ STEP 6 CHOOSE OPERATING SYSTEM, page 16 ■ STEP 7 CHOOSE OPERATING SYSTEM MEDIA KIT, page 19 ■ STEP 8 CHOOSE OPTIONAL VALUE-ADDED SOFTWARE, page 20 ■ STEP 9 CHOOSE SERVICE and SUPPORT LEVEL, page 21...
CONFIGURING the SERVER CONFIGURING the SERVER Follow these steps to configure the Cisco UCS B200 Blade Server: ■ STEP 1 VERIFY BASE SKU, page 7 ■ STEP 2 CHOOSE CPU(S), page 8 ■ STEP 3 CHOOSE MEMORY, page 10 ■ STEP 4 CHOOSE HARD ...DISK DRIVES or SOLID STATE DRIVES, page 14 ■ STEP 5 CHOOSE A PCIe MEZZANINE CARD, page 15 ■ STEP 6 CHOOSE OPERATING SYSTEM, page 16 ■ STEP 7 CHOOSE OPERATING SYSTEM MEDIA KIT, page 19 ■ STEP 8 CHOOSE OPTIONAL VALUE-ADDED SOFTWARE, page 20 ■ STEP 9 CHOOSE SERVICE and SUPPORT LEVEL, page 21...
Specifications
Page 11
...mirroring option Voltage Ranks /DIMM 1.35/1.5 V 1 1.35/1.5 V 2 1.35/1.5 V 2 4GB DDR3-1333-MHz UDIMM/PC3-10600/single rank/x4/1.35v Cisco UCS B200 M2 Blade Server 11 The available memory DIMMs are listed in Table 5. A transient or soft error in one channel does not affect the... data, and operation continues unless there is enabled, the memory subsystem simultaneously writes identical data to an uncorrectable memory error, the system automatically retrieves the data from one of the channels returns incorrect data due to two channels. The available memory DIMMs and mirroring ...
...mirroring option Voltage Ranks /DIMM 1.35/1.5 V 1 1.35/1.5 V 2 1.35/1.5 V 2 4GB DDR3-1333-MHz UDIMM/PC3-10600/single rank/x4/1.35v Cisco UCS B200 M2 Blade Server 11 The available memory DIMMs are listed in Table 5. A transient or soft error in one channel does not affect the... data, and operation continues unless there is enabled, the memory subsystem simultaneously writes identical data to an uncorrectable memory error, the system automatically retrieves the data from one of the channels returns incorrect data due to two channels. The available memory DIMMs and mirroring ...
Specifications
Page 12
NOTE: System performance is not used with memory mirroring) 1 DIMM in Channel A, 1 DIMM in Channel B 2 DIMMs in Channel A, 2 DIMMs in Channel B ■ Select the memory mirroring option (... placed by the factory as shown in the following table: Number of DIMMs per CPU 2 4 DIMM Placement (Channels C and F are equal for both CPUs. 12 Cisco UCS B200 M2 Blade Server CONFIGURING the SERVER Approved Configurations (1) 1-CPU configuration without memory mirroring: ■ Select from one to six DIMMs (note that there...
NOTE: System performance is not used with memory mirroring) 1 DIMM in Channel A, 1 DIMM in Channel B 2 DIMMs in Channel A, 2 DIMMs in Channel B ■ Select the memory mirroring option (... placed by the factory as shown in the following table: Number of DIMMs per CPU 2 4 DIMM Placement (Channels C and F are equal for both CPUs. 12 Cisco UCS B200 M2 Blade Server CONFIGURING the SERVER Approved Configurations (1) 1-CPU configuration without memory mirroring: ■ Select from one to six DIMMs (note that there...
Specifications
Page 13
If you only have two DIMMs, they need to operate in a 2-CPU system, for example, you cannot implement RAS on Channel D of CPU 2. If you have four ... into effect on Channel B of CPU 1, and one 4-GB/8-GB DIMM pair would be located on three channels). Cisco UCS B200 M2 Blade Server 13 If you can have two 4-GB and two 8-GB DIMMs. One 4-GB/8-GB DIMM...CPU 1. In this case, two DIMMS would be located on only two channels with an even number of DIMMs in a 1-CPU system, for example, you have one DIMM on page 26. You can be operated in either 1.5 V or 1.35 V) and single ...
If you only have two DIMMs, they need to operate in a 2-CPU system, for example, you cannot implement RAS on Channel D of CPU 2. If you have four ... into effect on Channel B of CPU 1, and one 4-GB/8-GB DIMM pair would be located on three channels). Cisco UCS B200 M2 Blade Server 13 If you can have two 4-GB and two 8-GB DIMMs. One 4-GB/8-GB DIMM...CPU 1. In this case, two DIMMS would be located on only two channels with an even number of DIMMs in a 1-CPU system, for example, you have one DIMM on page 26. You can be operated in either 1.5 V or 1.35 V) and single ...
Specifications
Page 15
... CNA M61KR-I Intel Converged Network Adapter Network Interface Cards (NICs) N20-AB0002 Cisco UCS NIC M51KR-B Broadcom BCM57711 Network Adapter Approved Configurations (1) Select one PCIe Mezzanine Cards (mandatory) You must select one card. To help ensure that your operating system is compatible with the cards you have selected, please check the Hardware Compatibility...
... CNA M61KR-I Intel Converged Network Adapter Network Interface Cards (NICs) N20-AB0002 Cisco UCS NIC M51KR-B Broadcom BCM57711 Network Adapter Approved Configurations (1) Select one PCIe Mezzanine Cards (mandatory) You must select one card. To help ensure that your operating system is compatible with the cards you have selected, please check the Hardware Compatibility...
Specifications
Page 16
...1Yr Svcs Required RHEL-RS-2S-1A RHEL Option/Resilient w/Ha /2 Socket/1 Yr Svcs Required RHEL-SFS-2S-1A RHEL Option/Scalable File System/2 Socket/1 Yr Svcs Required RHEL-HA-2S-3A RHEL Option/High-Availability/2 Socket/3Yr Svcs Required RHEL-RS-2S-3A RHEL Option/Resilient ...1Yr Redhat Svcs Incld RHEL-RS-2S-1A-RS RHEL Option/Resilient Storage/2 Socket/1 Yr Redhat Svcs Incl 16 Cisco UCS B200 M2 Blade Server Choose one of the operating systems listed in Table 8. CONFIGURING the SERVER STEP 6 CHOOSE OPERATING SYSTEM Several operating systems are available from which to choose.
...1Yr Svcs Required RHEL-RS-2S-1A RHEL Option/Resilient w/Ha /2 Socket/1 Yr Svcs Required RHEL-SFS-2S-1A RHEL Option/Scalable File System/2 Socket/1 Yr Svcs Required RHEL-HA-2S-3A RHEL Option/High-Availability/2 Socket/3Yr Svcs Required RHEL-RS-2S-3A RHEL Option/Resilient ...1Yr Redhat Svcs Incld RHEL-RS-2S-1A-RS RHEL Option/Resilient Storage/2 Socket/1 Yr Redhat Svcs Incl 16 Cisco UCS B200 M2 Blade Server Choose one of the operating systems listed in Table 8. CONFIGURING the SERVER STEP 6 CHOOSE OPERATING SYSTEM Several operating systems are available from which to choose.
Specifications
Page 17
CONFIGURING the SERVER Table 8 Operating Systems (continued) PID Description RHEL-SFS-2S-1A-RS RHEL-HA-2S-3A-RS RHEL-RS-2S-3A-RS RHEL-SFS-2S-3A-RS Windows Server ... 1 Processor, 4 Year Support VMware vSphere 5 Enterprise Plus for 1 Processor, 5 Year, Support VMware vCenter 5 Standard for 1 Processor, 1 Year, Support R VMware vCenter 5 Standard for 1 Processor, 2 Year, Support R Cisco UCS B200 M2 Blade Server 17
CONFIGURING the SERVER Table 8 Operating Systems (continued) PID Description RHEL-SFS-2S-1A-RS RHEL-HA-2S-3A-RS RHEL-RS-2S-3A-RS RHEL-SFS-2S-3A-RS Windows Server ... 1 Processor, 4 Year Support VMware vSphere 5 Enterprise Plus for 1 Processor, 5 Year, Support VMware vCenter 5 Standard for 1 Processor, 1 Year, Support R VMware vCenter 5 Standard for 1 Processor, 2 Year, Support R Cisco UCS B200 M2 Blade Server 17
Specifications
Page 18
CONFIGURING the SERVER Table 8 Operating Systems (continued) PID Description Product ID (PID) VMW-VC5-ST-3A VMW-VC5-ST-4A VMW-VC5-ST-5A VMware vCenter 5 Standard for 1 Processor, 3 Year, Support R VMware vCenter 5 Standard for 1 Processor, 4 Year, Support R VMware vCenter 5 Standard for 1 Processor, 5 Year, Support R 18 Cisco UCS B200 M2 Blade Server
CONFIGURING the SERVER Table 8 Operating Systems (continued) PID Description Product ID (PID) VMW-VC5-ST-3A VMW-VC5-ST-4A VMW-VC5-ST-5A VMware vCenter 5 Standard for 1 Processor, 3 Year, Support R VMware vCenter 5 Standard for 1 Processor, 4 Year, Support R VMware vCenter 5 Standard for 1 Processor, 5 Year, Support R 18 Cisco UCS B200 M2 Blade Server
Specifications
Page 19
Table 9 OS Media Product ID (PID) RHEL-6 SLES-11 MSWS-08R2-STHV-RM MSWS-08RS-ENHV-RM MSWS-08R2-DCHV-RM PID Description RHEL 6 Recovery Media Only (Multilingual) SLES 11 media only (multilingual) Windows Svr 2008 R2 ST (1-4CPU, 5CAL), Media Windows Svr 2008 R2 EN (1-8CPU, 25CAL), Media Windows Svr 2008 R2 DC (1-8CPU, 25CAL), Media Cisco UCS B200 M2 Blade Server 19 CONFIGURING the SERVER STEP 7 CHOOSE OPERATING SYSTEM MEDIA KIT Choose the optional operating system media listed in Table 9.
Table 9 OS Media Product ID (PID) RHEL-6 SLES-11 MSWS-08R2-STHV-RM MSWS-08RS-ENHV-RM MSWS-08R2-DCHV-RM PID Description RHEL 6 Recovery Media Only (Multilingual) SLES 11 media only (multilingual) Windows Svr 2008 R2 ST (1-4CPU, 5CAL), Media Windows Svr 2008 R2 EN (1-8CPU, 25CAL), Media Windows Svr 2008 R2 DC (1-8CPU, 25CAL), Media Cisco UCS B200 M2 Blade Server 19 CONFIGURING the SERVER STEP 7 CHOOSE OPERATING SYSTEM MEDIA KIT Choose the optional operating system media listed in Table 9.
Specifications
Page 21
... no service contract, the following coverage is also access to Cisco's extensive online technical resources to help sustain performance and high availability of the entire Unified Computing System, Cisco offers the Cisco Unified Computing Support Service. For UCS blade servers, there is... of BIOS, drivers, and firmware updates. ■ UCSM updates for the Cisco Unified Computing System (UCS). Unified Computing Warranty, No Contract If you have noncritical implementations and choose to Cisco Technical Assistance Center (TAC) is Smart Call Home, which provides proactive, embedded...
... no service contract, the following coverage is also access to Cisco's extensive online technical resources to help sustain performance and high availability of the entire Unified Computing System, Cisco offers the Cisco Unified Computing Support Service. For UCS blade servers, there is... of BIOS, drivers, and firmware updates. ■ UCSM updates for the Cisco Unified Computing System (UCS). Unified Computing Warranty, No Contract If you have noncritical implementations and choose to Cisco Technical Assistance Center (TAC) is Smart Call Home, which provides proactive, embedded...
Specifications
Page 22
...return materials authorization (RMA) is provided with the standard Cisco Unified Computing System warranty, Cisco offers the Cisco Unified Computing Warranty Plus Service. Table 12 UCS Computing Support Service Product ID (PID) On Site? Warranty Plus provides remote access any time to Cisco support professionals who can choose a desired service listed in...UC Warranty Plus 8X5X4 CON-UCW7-B200-M2 Yes UC Warranty Plus 24x7x4 CON-UCW8-B200-M2 Yes UC Warranty Plus 24x7x2 22 Cisco UCS B200 M2 Blade Server Description CON-UCS1-B200-M2 No CON-UCS2-B200-M2 No CON-UCS3-B200-M2 No CON-...
...return materials authorization (RMA) is provided with the standard Cisco Unified Computing System warranty, Cisco offers the Cisco Unified Computing Warranty Plus Service. Table 12 UCS Computing Support Service Product ID (PID) On Site? Warranty Plus provides remote access any time to Cisco support professionals who can choose a desired service listed in...UC Warranty Plus 8X5X4 CON-UCW7-B200-M2 Yes UC Warranty Plus 24x7x4 CON-UCW8-B200-M2 Yes UC Warranty Plus 24x7x2 22 Cisco UCS B200 M2 Blade Server Description CON-UCS1-B200-M2 No CON-UCS2-B200-M2 No CON-UCS3-B200-M2 No CON-...
Specifications
Page 23
..., sensitive, or proprietary data, you can obtain a new disk drive in exchange for a Cisco replacement drive, you to retain your drives and ensures that the drive has been removed from the system listed, is not compromised, thereby reducing the risk of any potential liabilities. NOTE...: Cisco does not offer a certified drive destruction service as part of this service. Sophisticated data ...
..., sensitive, or proprietary data, you can obtain a new disk drive in exchange for a Cisco replacement drive, you to retain your drives and ensures that the drive has been removed from the system listed, is not compromised, thereby reducing the risk of any potential liabilities. NOTE...: Cisco does not offer a certified drive destruction service as part of this service. Sophisticated data ...
Specifications
Page 24
...-UCWD7-B200-M2SFF CON-UCWD8-B200-M2SFF For more service and support information, see the following URL: http://www.cisco.com/en/US/services/ps2961/ps10312/ps10321/Cisco_UC_Warranty_Support_DS.pdf For a complete listing of available services for Cisco Unified Computing System, see this URL: http://www.cisco.com/en/US/products/ps10312/serv_group_home.html 24...
...-UCWD7-B200-M2SFF CON-UCWD8-B200-M2SFF For more service and support information, see the following URL: http://www.cisco.com/en/US/services/ps2961/ps10312/ps10321/Cisco_UC_Warranty_Support_DS.pdf For a complete listing of available services for Cisco Unified Computing System, see this URL: http://www.cisco.com/en/US/products/ps10312/serv_group_home.html 24...
Specifications
Page 25
... CABLE The KVM cable provides a connection into the server, providing a DB9 serial connector, a VGA connector for a monitor, and dual USB 2.0 ports for a mouse and keyboard) Cisco UCS B200 M2 Blade Server 25 The KVM cable ordering information is listed in Table 15. With this cable, you can create a direct connection to... (for a keyboard and mouse. Table 15 KVM Cable Product ID (PID) 37-1016-01 PID Description KVM Cable Figure 4 KVM Cable 1 Connector (to the operating system and the BIOS running on the server.
... CABLE The KVM cable provides a connection into the server, providing a DB9 serial connector, a VGA connector for a monitor, and dual USB 2.0 ports for a mouse and keyboard) Cisco UCS B200 M2 Blade Server 25 The KVM cable ordering information is listed in Table 15. With this cable, you can create a direct connection to... (for a keyboard and mouse. Table 15 KVM Cable Product ID (PID) 37-1016-01 PID Description KVM Cable Figure 4 KVM Cable 1 Connector (to the operating system and the BIOS running on the server.
Specifications
Page 29
Cisco UCS B200 M2 Blade Server 29 TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS Dimensions and Weight Table 17 UCS B200 M2 Dimensions and Weight1 Parameter Value Height Width Depth Weight 1.95 in. (50 mm) 8.00 in.(203 mm) 24.4 in. (620 mm) 13.5 lbs (6.1 kg)* Notes . . . 1. The system ...weight given here is an estimate for a fully configured system and will vary depending on the number of CPUs, memory DIMMs, and other optional items. Power Specifications For configuration-specific power...
Cisco UCS B200 M2 Blade Server 29 TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS Dimensions and Weight Table 17 UCS B200 M2 Dimensions and Weight1 Parameter Value Height Width Depth Weight 1.95 in. (50 mm) 8.00 in.(203 mm) 24.4 in. (620 mm) 13.5 lbs (6.1 kg)* Notes . . . 1. The system ...weight given here is an estimate for a fully configured system and will vary depending on the number of CPUs, memory DIMMs, and other optional items. Power Specifications For configuration-specific power...