When Were These Manufactured? Ws-c4506
(Posted by rgalbre2 11 years ago)

Cisco WS-C4506 Videos

Cisco WS-C4506-E $2885 Price Reduction
Duration: :34
Total Views: 187
Cisco WS-C4506 $450 Price Reduction
Duration: :34
Total Views: 22

Popular Cisco WS-C4506 Manual Pages

Software Guide - Page 29

... Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 xxix To access the Cisco TAC website, go to this URL: http://www.cisco.com/tac All customers, partners, and resellers who need information or assistance concerning Cisco product capabilities, product installation, or basic product configuration. Some services on the priority of Cisco products. Two types of...
Software Guide - Page 177

...." 78-15486-01 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 9-1 Note For complete information on the Catalyst enterprise LAN switches. Configuring VTP CH A P T E R 9 This chapter describes how to the Catalyst 4500 Series, Catalyst 2948G, and Catalyst 2980G Switches Command Reference. Note For complete syntax and usage information for...
Software Guide - Page 222

... Chapter 10 Configuring VLANs The default setting is a VLAN that the switch not send any auxiliary VLAN information in privileged mode: Task Verify auxiliary VLAN configuration status. Broadcasts propagate only between associated community ports and the promiscuous port. 10-16 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 78...
Software Guide - Page 298

... Software Configuration Guide-Release 8.1 78-15486-01 The value for example, GMRP and GVRP) will not operate successfully. The more registered attributes there are set to 350 ms. Caution Set the same GARP timer values on switches with many registered multicast groups, increase the timer values to 650 milliseconds. Configuring GMRP Chapter 15 Configuring Multicast Services When...
Software Guide - Page 300

... (the asterisks indicate that the entry was manually configured): Console> (enable) set multicast router 3/1 Port 3/1 added to which ports a multicast router is connected. Console> (enable) show multicast group CGMP enabled IGMP disabled 15-16 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 78-15486-01 Console> (enable...
Software Guide - Page 398

... or Catalyst 6500 series switch supervisor engine You cannot place any third-party or other Cisco switches in the end-to continue (y/n) [n]? y Disabled Port 2/3 to disable SPAN on page 26-1 for RSPAN traffic. Understanding How RSPAN Works Note See the "Understanding How SPAN and RSPAN Work" section on the switch: Console> (enable) set span disable 2/3 This command...
Software Guide - Page 423

...maximum available power for chassis and inline power for each power supply. 78-15486-01 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 28-3 Variable power supplies automatically adjust the power resources to accommodate the chassis and inline power requirements. • When your switch is set your switch accepts the configuration but...
Software Guide - Page 424

..., Catalyst 2980G Switches Software Configuration Guide-Release 8.1 78-15486-01 The backplane consumes 10 W in redundant mode. 4. Understanding How Power Management Works on the Catalyst 4500 Series Switches Chapter 28 Power Management Available Power for Power Supplies Table 28-1 lists the power that is provided by the supervisor engine(s), the fan trays, and the installed modules...
Software Guide - Page 425

... 2980G Switches Software Configuration Guide-Release 8.1 28-5 If you set power dcinput command to the devices is cut and some devices may power down a switch, and you insert an additional module or change the module configuration so that the power requirements exceed the available power, when you use the 1400 W DC power supply with Supervisor Engine II, use the 1400 W DC power supply with...
Software Guide - Page 430

...-port 10/100/1000BASE-T switching module WS-X4548-GB-RJ45 2-port 1000BASE-X (GBIC) Gigabit Ethernet WS-X4302-GB Power Consumed During Operation (W) 90 Power Consumed in Reset Mode (W) 50 65 40 60 50 10 10 88 10 58 15 35 30 Migrating a Supervisor Engine II from a Catalyst 4006 Switch to a Catalyst 4500 Series Switch If you migrate a Supervisor Engine II from 1 to the...
Software Guide - Page 432

... power is set to Auto mode. 28-12 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 78-15486-01 The supervisor engine then decreases the allocated power to the required amount if the port is 7 W for the port is less than the hardware-supported maximum value. • Static-The supervisor engine directs the switching module to power...
Software Guide - Page 433

..., Catalyst 2980G Switches Software Configuration Guide-Release 8.1 28-13 Phone Removal The switching module informs the supervisor engine if a powered phone is not added back to the switching module. During this through CDP messaging with 802.11a and 802.11b radio installed Required Power (W) 6.3 7 15.4 11 Wall-Powered Phones When a wall-powered phone is removed. Power for the link...
Software Guide - Page 437

..., 10:24:04 Power Capacity of the Chassis: 1 supply 78-15486-01 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 28-17 Command show system This example shows how to display the output for the switch: Console> (enable) set the power budget to 1 (1+1 redundancy mode) and display the power budget and current power usage for the show...
Software Guide - Page 480

... do not make Kerberos authentication mandatory and Kerberos authentication fails, the application attempts to authenticate users using the default method of authentication for that network service. clear kerberos credentials forward 30-36 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 78-15486-01
Software Guide - Page 526

... the Flash memory system devices. By default, port 1/1 is configured properly. • Ensure that support the Flash file system, you can download the Flash code again through an enabled port in the same subnetwork if you are also prompted for the specific username. If the Flash code is copied to copy the file and the destination filename. Note The switch remains...

Cisco WS-C4506 Reviews

Do you have an experience with the Cisco WS-C4506 that you would like to share?
Earn 750 points for your review!
We have not received any reviews for Cisco yet.

Popular Cisco WS-C4506 Search Terms

The following terms are frequently used to search for Cisco WS-C4506 support:

Ask a New Question
Use the box below to post a new question about Cisco WS-C4506.
Manuals / Documents
Download any of our Cisco WS-C4506 manuals for free!

We have the following 1 documents available for the Cisco WS-C4506:
  • Software Guide

Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Cisco Manuals

Find free Cisco WS-C4506 - Syst. Catalyst 4500 Switch manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Cisco Reviews

View thousands of Cisco WS-C4506 - Syst. Catalyst 4500 Switch user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Cisco customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Cisco customer service rankings, employee comments and much more from our sister site.