... the UPS has a Manual Bypass Switch 3 (MBS) MBS is set to Normal and the interlock bracket is secured to the right OR when the MBS is set to the left and right hanging brackets are securely on its side with installation, troubleshooting, or general product questions. See User's Manual for a couple of Operation: Monday - Technical Support | 1-877-297-6937...
... the UPS has a Manual Bypass Switch 3 (MBS) MBS is set to Normal and the interlock bracket is secured to the right OR when the MBS is set to the left and right hanging brackets are securely on its side with installation, troubleshooting, or general product questions. See User's Manual for a couple of Operation: Monday - Technical Support | 1-877-297-6937...
User Manual 1
Page 1
K01-0000755-01 SMART APP ONLINE STEP-DOWN TRANSFORMER INSTALLATION AND OPERATION MANUAL OL6KSTF | OL10KSTF SAVE THESE INSTRUCTIONS Please read this manual and follow the instructions for installation and operation. ©201 Cyber Power Systems, Inc. All rights reserve.
K01-0000755-01 SMART APP ONLINE STEP-DOWN TRANSFORMER INSTALLATION AND OPERATION MANUAL OL6KSTF | OL10KSTF SAVE THESE INSTRUCTIONS Please read this manual and follow the instructions for installation and operation. ©201 Cyber Power Systems, Inc. All rights reserve.
User Manual 1
Page 2
... of conductive contaminants. The batteries contain lead acid. SPECIAL SYMBOLS Warning: High voltage - Important Instructions: must always be followed during installation and maintenance of the STEP-DOWN TRANSFORMER The Smart App Online OL6KSTF and OL10KSTF step-down transformer models that should be followed. Information, advice, help See applicable user manual ©2019 Cyber Power Systems (USA), Inc. For...
... of conductive contaminants. The batteries contain lead acid. SPECIAL SYMBOLS Warning: High voltage - Important Instructions: must always be followed during installation and maintenance of the STEP-DOWN TRANSFORMER The Smart App Online OL6KSTF and OL10KSTF step-down transformer models that should be followed. Information, advice, help See applicable user manual ©2019 Cyber Power Systems (USA), Inc. For...
User Manual 1
Page 3
... Power Systems (USA), Inc. Never install a step-down transformer. Use tools with insulated handles. Remove watches, rings or other trademarks are the property of your equipment and cause fire hazards. III Please use only UL-marked power cables to connect any maintenance, repairs or... temperature and humidity range). the mains cable of their respective owners. DO NOT INSTALL THE STEP-DOWN TRANSFORMER WHERE IT WOULD BE EXPOSED TO DIRECT SUNLIGHT OR NEAR A STRONG HEAT SOURCE! SAFETY INSTRUCTIONS CONT. any equipment to the step-down transformer, check that...
... Power Systems (USA), Inc. Never install a step-down transformer. Use tools with insulated handles. Remove watches, rings or other trademarks are the property of your equipment and cause fire hazards. III Please use only UL-marked power cables to connect any maintenance, repairs or... temperature and humidity range). the mains cable of their respective owners. DO NOT INSTALL THE STEP-DOWN TRANSFORMER WHERE IT WOULD BE EXPOSED TO DIRECT SUNLIGHT OR NEAR A STRONG HEAT SOURCE! SAFETY INSTRUCTIONS CONT. any equipment to the step-down transformer, check that...
User Manual 1
Page 4
...see specifications for medical applications involving life support equipment and/ or patient care. SAFETY INSTRUCTIONS CONT. Wiring must be done by qualified personnel. DO NOT plug the step-down transformer models covered in this unit be placed near aquariums. ...install in contact with metal electrical contacts and cause equipment to a grounded AC power source with a ground wire. DO NOT USE FOR MEDICAL OR LIFE SUPPORT EQUIPMENT! All other cables are the property of fire, do not remove cover. PERSONAL SAFETY CONT. No user serviceable parts...
...see specifications for medical applications involving life support equipment and/ or patient care. SAFETY INSTRUCTIONS CONT. Wiring must be done by qualified personnel. DO NOT plug the step-down transformer models covered in this unit be placed near aquariums. ...install in contact with metal electrical contacts and cause equipment to a grounded AC power source with a ground wire. DO NOT USE FOR MEDICAL OR LIFE SUPPORT EQUIPMENT! All other cables are the property of fire, do not remove cover. PERSONAL SAFETY CONT. No user serviceable parts...
User Manual 1
Page 5
... CONTENTS SAFETY INSTRUCTIONS...II Special Symbols...II Personal Safety...III Product Safety ...IV INTRODUCTION...1 Unpacking Procedures...1 Whats In The Box...2 OVERVIEW...3 Step-Down Transformer...3 HARDWARE INSTALLATION ...4 Rackmount Installation For 4-Post Rack ...4 Rackmount Installation For 2-Post Rack ...6 Vertical/Tower Installation...7 ELECTRICAL INSTALLATION...8 Hardwiring the Input/Output Terminals...8 Connecting a Step-Down Transformer to a UPS Power Module 10 TECHNICAL SPECIFICATIONS...11...
... CONTENTS SAFETY INSTRUCTIONS...II Special Symbols...II Personal Safety...III Product Safety ...IV INTRODUCTION...1 Unpacking Procedures...1 Whats In The Box...2 OVERVIEW...3 Step-Down Transformer...3 HARDWARE INSTALLATION ...4 Rackmount Installation For 4-Post Rack ...4 Rackmount Installation For 2-Post Rack ...6 Vertical/Tower Installation...7 ELECTRICAL INSTALLATION...8 Hardwiring the Input/Output Terminals...8 Connecting a Step-Down Transformer to a UPS Power Module 10 TECHNICAL SPECIFICATIONS...11...
User Manual 1
Page 6
...), Inc. INTRODUCTION The CyberPower Step-Down and Isolation Transformers support hardwire installations (OL6KSTF/ OL10KSTF) and are designed for all handling operations, including unpacking, lifting, and installation in a rack system. All rights reserved. At least two people are provided to carry the unit around; Wear safety shoes and use the lifting straps to manually unpack the unit...
...), Inc. INTRODUCTION The CyberPower Step-Down and Isolation Transformers support hardwire installations (OL6KSTF/ OL10KSTF) and are designed for all handling operations, including unpacking, lifting, and installation in a rack system. All rights reserved. At least two people are provided to carry the unit around; Wear safety shoes and use the lifting straps to manually unpack the unit...
User Manual 1
Page 7
...QUICK START GUIDE x1 INSTALLATION AND OL6KSTF 6,000 VA/6,000 W STEP-DOWN OPERATION MANUAL x1 AND ISOLATION TRANSFORMER OR OL10KSTF 10,000 VA/10,000 W STEP-DOWN AND ISOLATION TRANSFORMER x1 6 FT NEMA L6-30 LOCKING MALE PLUG TO 3-WIRE ROJ (REMOVE OUTER JACKET) POWER CABLE (...INSTALLATION TIE PLATE x1 BLACK M5X7L FLAT HEAD SCREWS x8 BLACK M5X12L PAN HEAD SCREWS x12 SILVER M5X6L PAN HEAD SCREWS x6 PLASTIC WASHERS x8 SCREW HOLE DUST COVERS x12 RUBBER PADS x12 ©2019 Cyber Power Systems (USA), Inc. All rights reserved. All other trademarks are the property of their respective owners...
...QUICK START GUIDE x1 INSTALLATION AND OL6KSTF 6,000 VA/6,000 W STEP-DOWN OPERATION MANUAL x1 AND ISOLATION TRANSFORMER OR OL10KSTF 10,000 VA/10,000 W STEP-DOWN AND ISOLATION TRANSFORMER x1 6 FT NEMA L6-30 LOCKING MALE PLUG TO 3-WIRE ROJ (REMOVE OUTER JACKET) POWER CABLE (...INSTALLATION TIE PLATE x1 BLACK M5X7L FLAT HEAD SCREWS x8 BLACK M5X12L PAN HEAD SCREWS x12 SILVER M5X6L PAN HEAD SCREWS x6 PLASTIC WASHERS x8 SCREW HOLE DUST COVERS x12 RUBBER PADS x12 ©2019 Cyber Power Systems (USA), Inc. All rights reserved. All other trademarks are the property of their respective owners...
User Manual 1
Page 8
All rights reserved. OVERVIEW STEP-DOWN TRANSFORMER 12 FRONT: OL6KSTF/OL10KSTF BACK: OL6KSTF/OL10KSTF 1. Input Circuit Breaker Provides input overload and fault protection. 2. All other trademarks are the property of their respective owners. 3 Output Circuit Breaker (120Vac) Provides output overload and fault protection. 34 ©2019 Cyber Power Systems (USA), Inc. Input/Output Terminal Block Connect to input power source / output to equipment load. 3. 6x NEMA 5-20R Outlets (120Vac) Output receptacles to connect equipment load. 4.
All rights reserved. OVERVIEW STEP-DOWN TRANSFORMER 12 FRONT: OL6KSTF/OL10KSTF BACK: OL6KSTF/OL10KSTF 1. Input Circuit Breaker Provides input overload and fault protection. 2. All other trademarks are the property of their respective owners. 3 Output Circuit Breaker (120Vac) Provides output overload and fault protection. 34 ©2019 Cyber Power Systems (USA), Inc. Input/Output Terminal Block Connect to input power source / output to equipment load. 3. 6x NEMA 5-20R Outlets (120Vac) Output receptacles to connect equipment load. 4.
User Manual 1
Page 9
... 4-POST RACK Caution: Important Instructions To prevent the risk of their respective owners. 4 Step 2: Rackmount ear & hanging bracket installation Attach two rack mount ears to the step-down transformer using six silver M5X6L pan head screws. 1 2 Step 3: Rackmount rail Installation The rails adjust to temporarily support the rails in (48 cm) racks from the screw...
... 4-POST RACK Caution: Important Instructions To prevent the risk of their respective owners. 4 Step 2: Rackmount ear & hanging bracket installation Attach two rack mount ears to the step-down transformer using six silver M5X6L pan head screws. 1 2 Step 3: Rackmount rail Installation The rails adjust to temporarily support the rails in (48 cm) racks from the screw...
User Manual 1
Page 12
...to each rack mount ear to use as tower stands and screw them on to the left hand side of their respective owners. 7 VERTICAL/TOWER INSTALLATION Step 1: Adhere rubber pads Adhere the protective rubber pads to the EBM and the step-down transformer using four black M5X7L ...Extended Battery Module (EBM) secure the tie plate between the UPS, EBM and the step-down transformer. All other trademarks are the property of the step-down transformer using four silver M5X6L pan head screws for added stability as shown below. 1 2 ©2019 Cyber Power Systems (USA), Inc. HARDWARE INSTALLATION ...
...to each rack mount ear to use as tower stands and screw them on to the left hand side of their respective owners. 7 VERTICAL/TOWER INSTALLATION Step 1: Adhere rubber pads Adhere the protective rubber pads to the EBM and the step-down transformer using four black M5X7L ...Extended Battery Module (EBM) secure the tie plate between the UPS, EBM and the step-down transformer. All other trademarks are the property of the step-down transformer using four silver M5X6L pan head screws for added stability as shown below. 1 2 ©2019 Cyber Power Systems (USA), Inc. HARDWARE INSTALLATION ...
User Manual 1
Page 13
... are the property of their respective terminals as shown in the terminal block identification and configuration table. ELECTRICAL INSTALLATION Check wiring dimensions with the following table. Step 4: Secure the top cover Use four screws to secure the top terminal block ...to secure the bottom cover on to the step-down transformer. 1 2 3 4 ©2019 Cyber Power Systems (USA), Inc. STEP-DOWN AND ISOLATION TRANSFORMERS WITH HARDWIRE INPUT TERMINAL BLOCK OL6KSTF OL10KSTF WIRING AWG 10 AWG 6 AWG WIRING mm2 5.5 mm2 14.0 mm2 HARDWIRING THE INPUT/OUTPUT TERMINALS Step 1:...
... are the property of their respective terminals as shown in the terminal block identification and configuration table. ELECTRICAL INSTALLATION Check wiring dimensions with the following table. Step 4: Secure the top cover Use four screws to secure the top terminal block ...to secure the bottom cover on to the step-down transformer. 1 2 3 4 ©2019 Cyber Power Systems (USA), Inc. STEP-DOWN AND ISOLATION TRANSFORMERS WITH HARDWIRE INPUT TERMINAL BLOCK OL6KSTF OL10KSTF WIRING AWG 10 AWG 6 AWG WIRING mm2 5.5 mm2 14.0 mm2 HARDWIRING THE INPUT/OUTPUT TERMINALS Step 1:...
User Manual 1
Page 15
OL6KRTF OL8KRTF/OL10KRTF OL6KRTMBTF OL8KRTMBTF/OL10KRTMBTF ©2019 Cyber Power Systems (USA), Inc. All other trademarks are the property of their respective owners. 10 CONNECTING A STEP-DOWN TRANSFORMER TO A UPS POWER MODULE The following illustrations provide the recommended connections between a step-down transformer and a CyberPower Smart App Online UPS System. All rights reserved. ELECTRICAL INSTALLATION CONT.
OL6KRTF OL8KRTF/OL10KRTF OL6KRTMBTF OL8KRTMBTF/OL10KRTMBTF ©2019 Cyber Power Systems (USA), Inc. All other trademarks are the property of their respective owners. 10 CONNECTING A STEP-DOWN TRANSFORMER TO A UPS POWER MODULE The following illustrations provide the recommended connections between a step-down transformer and a CyberPower Smart App Online UPS System. All rights reserved. ELECTRICAL INSTALLATION CONT.
User Manual 1
Page 16
... Power Systems (USA), Inc. TECHNICAL SPECIFICATIONS MODELS CONFIGURATION Maximum Output Power (VA)* Maximum Output Power ...(W)* Form Factor INPUT Nominal Input Voltage Input Voltage Range Input Current Rating Input Frequency OUTPUT Nominal Output Voltage* UPS Outlets PHYSICAL Dimensions Net Weight ENVIRONMENTAL Operating Temperature Operating Relative Humidity SAFETY Conformance Approvals OL6KSTF OL10KSTF...V are derated by 10% for OL10KSTF PRODUCT REGISTRATION CyberPower requests that you complete and return...
... Power Systems (USA), Inc. TECHNICAL SPECIFICATIONS MODELS CONFIGURATION Maximum Output Power (VA)* Maximum Output Power ...(W)* Form Factor INPUT Nominal Input Voltage Input Voltage Range Input Current Rating Input Frequency OUTPUT Nominal Output Voltage* UPS Outlets PHYSICAL Dimensions Net Weight ENVIRONMENTAL Operating Temperature Operating Relative Humidity SAFETY Conformance Approvals OL6KSTF OL10KSTF...V are derated by 10% for OL10KSTF PRODUCT REGISTRATION CyberPower requests that you complete and return...
User Manual 1
Page 17
... this Warranty? Before contacting CyberPower, identify Your Product model number, the Purchase Date, and each item of Coverage? By using the CyberPower OL6KSTF/OL10KSTF. This warranty covers the Product for three years and connected equipment for a full refund prior to the Product and damaged because of the failure of their respective owners. 12 All other...
... this Warranty? Before contacting CyberPower, identify Your Product model number, the Purchase Date, and each item of Coverage? By using the CyberPower OL6KSTF/OL10KSTF. This warranty covers the Product for three years and connected equipment for a full refund prior to the Product and damaged because of the failure of their respective owners. 12 All other...
User Manual 1
Page 18
... paid for the Product (purchase receipt showing price paid is defective in material or workmanship, CyberPower will repair or replace it with the product. What Will We Do To Correct Problems? If the Product is required). LIMITED WARRANTY AND CONNECTED EQUIPMENT GUARANTEE CONT. CyberPower will refund to you contact CyberPower, identify the Product, the Purchase Date, and...
... paid for the Product (purchase receipt showing price paid is defective in material or workmanship, CyberPower will repair or replace it with the product. What Will We Do To Correct Problems? If the Product is required). LIMITED WARRANTY AND CONNECTED EQUIPMENT GUARANTEE CONT. CyberPower will refund to you contact CyberPower, identify the Product, the Purchase Date, and...
User Manual 1
Page 19
...The Product must have been plugged directly into the power source and the equipment connected to the Product must be replaced due to properly wired and grounded outlets (including compliance with electrical and safety codes of software. 2. Loss of or damage to it were ...installed, grounded and code-compliant 120 volt power lines in Any Event for use of the Following: 1. CyberPower Does Not Cover or Undertake Any Liability in the United States and Canada; Damage from causes other trademarks are those provided by transients in conformance with any license, instruction manual...
...The Product must have been plugged directly into the power source and the equipment connected to the Product must be replaced due to properly wired and grounded outlets (including compliance with electrical and safety codes of software. 2. Loss of or damage to it were ...installed, grounded and code-compliant 120 volt power lines in Any Event for use of the Following: 1. CyberPower Does Not Cover or Undertake Any Liability in the United States and Canada; Damage from causes other trademarks are those provided by transients in conformance with any license, instruction manual...
User Manual 1
Page 21
... device must be accurate, but CyberPower reserves the right to change or correct the contents and does not assume any interference that may cause harmful interference to comply with installation, troubleshooting, or general product questions. Cet...user will be required to contact our Tech Support department with the limits for omissions or errors. All rights reserved. Shielded signal cables must accept any responsibility for a Class A digital device, pursuant to be used in a commercial environment. This document is operated in accordance with the instruction manual...
... device must be accurate, but CyberPower reserves the right to change or correct the contents and does not assume any interference that may cause harmful interference to comply with installation, troubleshooting, or general product questions. Cet...user will be required to contact our Tech Support department with the limits for omissions or errors. All rights reserved. Shielded signal cables must accept any responsibility for a Class A digital device, pursuant to be used in a commercial environment. This document is operated in accordance with the instruction manual...
Datasheet
Page 1
...60 Hz 7 (6) NEMA 5-20R, (1) Hardwire Terminal Block Circuit Breaker Protected OL10KSTF STEP-DOWN TRANSFORMER For mission-critical enterprise applications requiring maximum power protection. The CyberPower Smart App Online OL10KSTF rack/tower step-down transformer has passed our highest quality standards in design, assembly... Storage Devices • VoIP Installations FEATURES • 10,000 VA/10,000 W • 120 V, 208 V, 50/60 Hz Output • Over Temperature Protection • Rack/Tower Form Factor • 3-Year Limited Warranty SPECIFICATIONS GENERAL Type Over Temperature Protection ...
...60 Hz 7 (6) NEMA 5-20R, (1) Hardwire Terminal Block Circuit Breaker Protected OL10KSTF STEP-DOWN TRANSFORMER For mission-critical enterprise applications requiring maximum power protection. The CyberPower Smart App Online OL10KSTF rack/tower step-down transformer has passed our highest quality standards in design, assembly... Storage Devices • VoIP Installations FEATURES • 10,000 VA/10,000 W • 120 V, 208 V, 50/60 Hz Output • Over Temperature Protection • Rack/Tower Form Factor • 3-Year Limited Warranty SPECIFICATIONS GENERAL Type Over Temperature Protection ...
Datasheet
Page 2
OL10KSTF STEP-DOWN TRANSFORMER SPECIFICATIONS CONT. CyberPower is a registered trademark and brand of their respective owners. All other trademarks are the property of Cyber Power Systems (USA), Inc. CSA C22.2 NO.107.3-05 RoHS Compliant Optional WEXT5YR-ACC2C 3 Years Limited ©2018 Cyber Power...condensing) 0 ft to 50,000 ft (0 to change, without notice, marketing programs, product offerings and specifications. CyberPower reserves the right to 15,000 m) 1914 BTU/h 58 dBA COMPATIBILITY UPS Models CERTIFICATIONS Safety Environmental WARRANTY Extended 2-Year Warranty Product ...
OL10KSTF STEP-DOWN TRANSFORMER SPECIFICATIONS CONT. CyberPower is a registered trademark and brand of their respective owners. All other trademarks are the property of Cyber Power Systems (USA), Inc. CSA C22.2 NO.107.3-05 RoHS Compliant Optional WEXT5YR-ACC2C 3 Years Limited ©2018 Cyber Power...condensing) 0 ft to 50,000 ft (0 to change, without notice, marketing programs, product offerings and specifications. CyberPower reserves the right to 15,000 m) 1914 BTU/h 58 dBA COMPATIBILITY UPS Models CERTIFICATIONS Safety Environmental WARRANTY Extended 2-Year Warranty Product ...