...24 Stack Management Examples ...25 Configuring Stacking ...31 Defining Ports ...32 Configuring Port Properties ...32 Viewing Port Properties ...34 ARP Settings...35 Configuring User Accounts...36 Managing System Logs...38 Configuring SNTP ...40 Configuring Daylight Savings Time ...42 Table of Contents PREFACE...I System Overview ...ii Viewing the Device...iii DGS-3100... Terminal Baud-Rate...2 Defining Stacking Units...3 Using the Web-Based User Interface ...4 Understanding the D-Link Embedded Web Interface ...5 Using the Tool Menu ...7 Displaying the Stack Status...7 Locating Devices...7 Backing...
...24 Stack Management Examples ...25 Configuring Stacking ...31 Defining Ports ...32 Configuring Port Properties ...32 Viewing Port Properties ...34 ARP Settings...35 Configuring User Accounts...36 Managing System Logs...38 Configuring SNTP ...40 Configuring Daylight Savings Time ...42 Table of Contents PREFACE...I System Overview ...ii Viewing the Device...iii DGS-3100... Terminal Baud-Rate...2 Defining Stacking Units...3 Using the Web-Based User Interface ...4 Understanding the D-Link Embedded Web Interface ...5 Using the Tool Menu ...7 Displaying the Stack Status...7 Locating Devices...7 Backing...
Product Manual
Page 9
...stations, and servers. Figure 1. The ports operate at 10/100/1000, and connect to backbones, end-stations, and servers. The DGS-3100 series also provides 4 Mini-GBIC (SFP) combo ports which connect fiber optic media to switches, servers, or network backbone. This... Server (EWS) or through a Command Line Interface (CLI). The DGS-3100-24TG provides an additional RS-232 port (console port) for the following: • DGS-3100 series Front Panel • DGS-3100-24TG Front Panel DGS-3100 Series Front Panel The DGS-3100 series provides 24/48 high performance 1000BASE-T ports.
...stations, and servers. Figure 1. The ports operate at 10/100/1000, and connect to backbones, end-stations, and servers. The DGS-3100 series also provides 4 Mini-GBIC (SFP) combo ports which connect fiber optic media to switches, servers, or network backbone. This... Server (EWS) or through a Command Line Interface (CLI). The DGS-3100-24TG provides an additional RS-232 port (console port) for the following: • DGS-3100 series Front Panel • DGS-3100-24TG Front Panel DGS-3100 Series Front Panel The DGS-3100 series provides 24/48 high performance 1000BASE-T ports.
Product Manual
Page 20
... vary slightly. 4 Enter the device IP address in this Guide represent the DGS-3100-48 48 port device. To access the D-Link user interface: 1. The screen captures in the address bar and press Enter. The Web pages in the 24 port and the DGS-3100-24TG devices may not open. 2. Open an Internet browser. The user...
... vary slightly. 4 Enter the device IP address in this Guide represent the DGS-3100-48 48 port device. To access the D-Link user interface: 1. The screen captures in the address bar and press Enter. The Web pages in the 24 port and the DGS-3100-24TG devices may not open. 2. Open an Internet browser. The user...
Product Manual
Page 26
NOTE: Firmware version 1.x.x supports 4 SKUs od DGS-3100 series: DGS-3100-24, DGS-310024P, DGS-3100-48 and DGS-3100-48P, Firmware version 2.x.x supports in firmware version 1.x.x. Firmware version 2.x.x includes as well additional features comparing to version 1.x.x, for ... 2.x.x, the value will happened because of access profile are in hexadecimal instead of decimal values. In firmware version 1.x.x, it is required. DGS-3100 Series Gigabit Stackable Managed Switch User Manual Downloading the Firmware The 'Firmware Download' web page is used to manage the device. In firmware...
NOTE: Firmware version 1.x.x supports 4 SKUs od DGS-3100 series: DGS-3100-24, DGS-310024P, DGS-3100-48 and DGS-3100-48P, Firmware version 2.x.x supports in firmware version 1.x.x. Firmware version 2.x.x includes as well additional features comparing to version 1.x.x, for ... 2.x.x, the value will happened because of access profile are in hexadecimal instead of decimal values. In firmware version 1.x.x, it is required. DGS-3100 Series Gigabit Stackable Managed Switch User Manual Downloading the Firmware The 'Firmware Download' web page is used to manage the device. In firmware...
Product Manual
Page 40
... assign Unit IDs to the Stack Master console port since the only operational console port in case of unit failure or stacking link failure. After a short interval the stack will become operational with one of the stack. The Master and Backup selection is ... the stacking members physically to the Backup Master 24 Managing a New Manually Ordered Stack System administrator can be either Ring or Chain. Managing a Self-Ordered Stack This section describes managing a self-ordered stack. Turn on the front panel. DGS-3100 Series Gigabit Stackable Managed Switch User Manual Building...
... assign Unit IDs to the Stack Master console port since the only operational console port in case of unit failure or stacking link failure. After a short interval the stack will become operational with one of the stack. The Master and Backup selection is ... the stacking members physically to the Backup Master 24 Managing a New Manually Ordered Stack System administrator can be either Ring or Chain. Managing a Self-Ordered Stack This section describes managing a self-ordered stack. Turn on the front panel. DGS-3100 Series Gigabit Stackable Managed Switch User Manual Building...
Product Manual
Page 42
...elected Stack Master. If the new stacking member has a Unit ID of 1 or 2, i.e. This may result in a Master Election process. DGS-3100 Series Gigabit Stackable Managed Switch User Manual - If the new stacking member already has an assigned Unit ID, and that automatic assigned Unit ID ...around the failed stacking member. In case of Ring topology the Backup Master directs all other stacking connections are configured according first 24 ports configuration of the replaced stacking member is unused in before stacking member failed. the stacking member is assigned the lowest ...
...elected Stack Master. If the new stacking member has a Unit ID of 1 or 2, i.e. This may result in a Master Election process. DGS-3100 Series Gigabit Stackable Managed Switch User Manual - If the new stacking member already has an assigned Unit ID, and that automatic assigned Unit ID ...around the failed stacking member. In case of Ring topology the Backup Master directs all other stacking connections are configured according first 24 ports configuration of the replaced stacking member is unused in before stacking member failed. the stacking member is assigned the lowest ...
Product Manual
Page 57
...in seconds) at which the SNTP server is polled for Time Information SNTP is used to enable and configure the SNTP time settings on the 24-hour clock (Military Time) For example, 9:00PM is Day/Month/Year. Click Configuration > SNTP Settings > Time Settings. The Time Settings ...Page opens: Figure 0-10. SNTP Poll Interval in Seconds Defines the interval (in HH MM SS Defines the current system time. DGS-3100 Series Gigabit Stackable Managed Switch User Manual Polling for Unicast information. The Time Settings Page allows network managers to poll time information from ...
...in seconds) at which the SNTP server is polled for Time Information SNTP is used to enable and configure the SNTP time settings on the 24-hour clock (Military Time) For example, 9:00PM is Day/Month/Year. Click Configuration > SNTP Settings > Time Settings. The Time Settings ...Page opens: Figure 0-10. SNTP Poll Interval in Seconds Defines the interval (in HH MM SS Defines the current system time. DGS-3100 Series Gigabit Stackable Managed Switch User Manual Polling for Unicast information. The Time Settings Page allows network managers to poll time information from ...
Product Manual
Page 61
...seasonal time adjustment. The field options are : First - Click . Daylight Savings Time is configured, and the device is Hour:Minutes based on the 24-hour clock (Military Time). Indicates the first week of the month DST ends. Third - The field range is configured as 21:00. For ...DST ends. To Day of Week Defines the week day DST starts. The field options are 1-31. The field options are January-December. DGS-3100 Series Gigabit Stackable Managed Switch User Manual The Repeating Mode enables setting repeating DST. Second - The field range is configured as 21:00....
...seasonal time adjustment. The field options are : First - Click . Daylight Savings Time is configured, and the device is Hour:Minutes based on the 24-hour clock (Military Time). Indicates the first week of the month DST ends. Third - The field range is configured as 21:00. For ...DST ends. To Day of Week Defines the week day DST starts. The field options are 1-31. The field options are January-December. DGS-3100 Series Gigabit Stackable Managed Switch User Manual The Repeating Mode enables setting repeating DST. Second - The field range is configured as 21:00....
Product Manual
Page 85
... with the change in this table: VLAN Name VID System (default) 1 Engineering 2 Marketing 3 Finance 4 Sales 5 Switch Ports 5, 6, 7, 8, 21, 22, 23, 24 9, 10, 11, 12 13, 14, 15, 16 17, 18, 19, 20 1, 2, 3, 4 Table 0-1. VLAN settings automatically change of packets that are not on trunk... unknown source addresses are configured on another VLAN, the link must be added as Untagged on the switch, then all ports. The members of the VLAN settings after changing the port trunk group settings. DGS-3100 Series Gigabit Stackable Managed Switch User Manual the ingress port...
... with the change in this table: VLAN Name VID System (default) 1 Engineering 2 Marketing 3 Finance 4 Sales 5 Switch Ports 5, 6, 7, 8, 21, 22, 23, 24 9, 10, 11, 12 13, 14, 15, 16 17, 18, 19, 20 1, 2, 3, 4 Table 0-1. VLAN settings automatically change of packets that are not on trunk... unknown source addresses are configured on another VLAN, the link must be added as Untagged on the switch, then all ports. The members of the VLAN settings after changing the port trunk group settings. DGS-3100 Series Gigabit Stackable Managed Switch User Manual the ingress port...
Product Manual
Page 94
Figure 0-11. DGS-3100 Series Gigabit Stackable Managed Switch User Manual Defining VLAN Trunking VLAN Trunking allows frames belonging to unknown VLAN groups to port 24. The VLAN Trunking Page opens: 78 In the example below, the user defined 'VLAN Trunking' ports (Uplinks) are applied to the user-defined Uplink ports: ... Trunking on the switch, VLANs 2-4094 will be forwarded to pass through functionality applies to all ports (see The following limitations are ports 23 and 24.
Figure 0-11. DGS-3100 Series Gigabit Stackable Managed Switch User Manual Defining VLAN Trunking VLAN Trunking allows frames belonging to unknown VLAN groups to port 24. The VLAN Trunking Page opens: 78 In the example below, the user defined 'VLAN Trunking' ports (Uplinks) are applied to the user-defined Uplink ports: ... Trunking on the switch, VLANs 2-4094 will be forwarded to pass through functionality applies to all ports (see The following limitations are ports 23 and 24.
Product Manual
Page 116
...this interval, it is a global (FDB) database setting. Aging time is discarded. Port Defines the port number. 2. DGS-3100 Series Gigabit Stackable Managed Switch User Manual Defining Forwarding and Filtering This section contains information for configuring both Unicast and Multicast ...Define the VID, MAC Address, Unit, and Port fields. 3. VID Defines the VLAN ID. The Unicast Forwarding Page opens: Figure 0-24. The Unicast are forwarded. Click . Unicast Forwarding Page The Unicast Forwarding Page contains the following topics: • Defining Unicast Forwarding ...
...this interval, it is a global (FDB) database setting. Aging time is discarded. Port Defines the port number. 2. DGS-3100 Series Gigabit Stackable Managed Switch User Manual Defining Forwarding and Filtering This section contains information for configuring both Unicast and Multicast ...Define the VID, MAC Address, Unit, and Port fields. 3. VID Defines the VLAN ID. The Unicast Forwarding Page opens: Figure 0-24. The Unicast are forwarded. Click . Unicast Forwarding Page The Unicast Forwarding Page contains the following topics: • Defining Unicast Forwarding ...
Product Manual
Page 222
... The Time Range Setting Page contains the following fields: Field Description Range Name Defines the Time Range Name. The Time Range Setting Page opens: Figure 0-24. The possible field values are : HH: 00 - 23 (hours, in military format) MM: 00 - 59 (minutes) Weekdays Specifies the weekdays...is enabled. Click ACL > Time Range Setting. To define the applicable days, check the specific Weekdays or check Select All Days. 4. DGS-3100 Series Gigabit Stackable Managed Switch User Manual Defining Time Ranges Time-based ACLs allow users to 32 time ranges can be defined. Up to ...
... The Time Range Setting Page contains the following fields: Field Description Range Name Defines the Time Range Name. The Time Range Setting Page opens: Figure 0-24. The possible field values are : HH: 00 - 23 (hours, in military format) MM: 00 - 59 (minutes) Weekdays Specifies the weekdays...is enabled. Click ACL > Time Range Setting. To define the applicable days, check the specific Weekdays or check Select All Days. 4. DGS-3100 Series Gigabit Stackable Managed Switch User Manual Defining Time Ranges Time-based ACLs allow users to 32 time ranges can be defined. Up to ...
Product Manual
Page 229
DGS-3100 Series Gigabit Stackable Managed Switch User Manual B SYSLOG ERRORS The Syslog Error Message Table displays a list of Syslog error messages appearing on the Switch according ....31 SYSLG8.16.6 SYSLG8.16.9 Critical Critical Critical Critical SYSLG8.47.35 Critical SYSLG8.47.37 SYSLG8.47.8 Critical Critical SYSLG8.49.22 SYSLG8.49.24 Critical Critical System System AAA Up/Download Up/Download IP IP SSH No free UDP port Cannot create private memory pool Session amount exceeded Illegal...
DGS-3100 Series Gigabit Stackable Managed Switch User Manual B SYSLOG ERRORS The Syslog Error Message Table displays a list of Syslog error messages appearing on the Switch according ....31 SYSLG8.16.6 SYSLG8.16.9 Critical Critical Critical Critical SYSLG8.47.35 Critical SYSLG8.47.37 SYSLG8.47.8 Critical Critical SYSLG8.49.22 SYSLG8.49.24 Critical Critical System System AAA Up/Download Up/Download IP IP SSH No free UDP port Cannot create private memory pool Session amount exceeded Illegal...
Product Manual
Page 230
... UNIT ID %(1)d,Msg:%(2)s UNIT ID %(1)d,Trap:%(2)s Cannot allocate memory for %(1)s The created specified area Create area %(1)s - Auto Update aborted. DGS-3100 Series Gigabit Stackable Managed Switch User Manual ID SEVERITY CATEGORY SYSLG8.63.10 Critical SYSLG8.63.2 Critical SYSLG8.74.46 Critical Stack Stack System ... SYSLG8.47.8 Critical Critical web System System System AAA Up/Download Up/Download IP IP SYSLG8.49.22 Critical SYSLG8.49.24 Critical SYSLG8.63.10 Critical SYSLG8.63.2 Critical SYSLG8.74.46 Critical SSH Stack Stack System SYSLG8.74.48 Critical System...
... UNIT ID %(1)d,Msg:%(2)s UNIT ID %(1)d,Trap:%(2)s Cannot allocate memory for %(1)s The created specified area Create area %(1)s - Auto Update aborted. DGS-3100 Series Gigabit Stackable Managed Switch User Manual ID SEVERITY CATEGORY SYSLG8.63.10 Critical SYSLG8.63.2 Critical SYSLG8.74.46 Critical Stack Stack System ... SYSLG8.47.8 Critical Critical web System System System AAA Up/Download Up/Download IP IP SYSLG8.49.22 Critical SYSLG8.49.24 Critical SYSLG8.63.10 Critical SYSLG8.63.2 Critical SYSLG8.74.46 Critical SSH Stack Stack System SYSLG8.74.48 Critical System...
Product Manual
Page 238
...the specified unit. removed from the stack. The IPC connection with unit %(1)d failed. DGS-3100 Series Gigabit Stackable Managed Switch User Manual ID SEVERITY CATEGORY SYSLG8.97.18 SYSLG1.0.55...Up/Download Interface SYSLG1.3.1 Information al System SYSLG1.3.2 Information al System SYSLG1.5.23 SYSLG1.5.24 Information al Information al Interface Stack SYSLG1.5.25 SYSLG1.5.26 SYSLG1.5.28 SYSLG1.5.29 Information...changed - %(2)s. PS# %(1)d status changed : %(1)s Stack cable %(1)s : link %(2)s on unit-%(3)d The specified stacking cable is now the Master unit.
...the specified unit. removed from the stack. The IPC connection with unit %(1)d failed. DGS-3100 Series Gigabit Stackable Managed Switch User Manual ID SEVERITY CATEGORY SYSLG8.97.18 SYSLG1.0.55...Up/Download Interface SYSLG1.3.1 Information al System SYSLG1.3.2 Information al System SYSLG1.5.23 SYSLG1.5.24 Information al Information al Interface Stack SYSLG1.5.25 SYSLG1.5.26 SYSLG1.5.28 SYSLG1.5.29 Information...changed - %(2)s. PS# %(1)d status changed : %(1)s Stack cable %(1)s : link %(2)s on unit-%(3)d The specified stacking cable is now the Master unit.
Product Manual
Page 245
...%(2)d failed, %(3)d mac failed to be inserted from the last trap %(1)s %(2)s port %(3)s Media changed : %(1)s Stack cable %(1)s : link %(2)s on unit-%(3)d The specified stacking cable is from the stack. The system supports the 229 Backup master unit %(1)d The specified backup was... Add dynamic MAC %(1)m - removed from %(1)s of %(4)j Activating service %(1)d... DGS-3100 Series Gigabit Stackable Managed Switch User Manual ID SEVERITY CATEGORY SYSLG1.3.2 SYSLG1.5.23 SYSLG1.5.24 SYSLG1.5.25 SYSLG1.5.26 SYSLG1.5.28 SYSLG1.5.29 SYSLG1.5.30 Information al System...
...%(2)d failed, %(3)d mac failed to be inserted from the last trap %(1)s %(2)s port %(3)s Media changed : %(1)s Stack cable %(1)s : link %(2)s on unit-%(3)d The specified stacking cable is from the stack. The system supports the 229 Backup master unit %(1)d The specified backup was... Add dynamic MAC %(1)m - removed from %(1)s of %(4)j Activating service %(1)d... DGS-3100 Series Gigabit Stackable Managed Switch User Manual ID SEVERITY CATEGORY SYSLG1.3.2 SYSLG1.5.23 SYSLG1.5.24 SYSLG1.5.25 SYSLG1.5.26 SYSLG1.5.28 SYSLG1.5.29 SYSLG1.5.30 Information al System...
Product Manual
Page 254
... %(1)s The IP address was configured without configuring IP address of TFTP server A BOOTP message must include a TFTP server IP address. DGS-3100 Series Gigabit Stackable Managed Switch User Manual ID SEVERITY CATEGORY SYSLG8.0.4 Warning IP SYSLG8.1.31 Warning STP SYSLG8.10.14 Warning bootup SYSLG8.10...DHCP SYSLG8.10.20 Warning bootup SYSLG8.10.21 Warning bootup SYSLG8.10.22 Warning DHCP SYSLG8.10.23 Warning DHCP SYSLG8.10.24 Warning DHCP SYSLG8.10.25 SYSLG8.10.26 Warning Warning bootup IP MESSAGE %(2)j: port is down/notPresent DESCRIPTION removed and is ...
... %(1)s The IP address was configured without configuring IP address of TFTP server A BOOTP message must include a TFTP server IP address. DGS-3100 Series Gigabit Stackable Managed Switch User Manual ID SEVERITY CATEGORY SYSLG8.0.4 Warning IP SYSLG8.1.31 Warning STP SYSLG8.10.14 Warning bootup SYSLG8.10...DHCP SYSLG8.10.20 Warning bootup SYSLG8.10.21 Warning bootup SYSLG8.10.22 Warning DHCP SYSLG8.10.23 Warning DHCP SYSLG8.10.24 Warning DHCP SYSLG8.10.25 SYSLG8.10.26 Warning Warning bootup IP MESSAGE %(2)j: port is down/notPresent DESCRIPTION removed and is ...
Product Manual
Page 264
... memory is removed. BOOTP msg indicates that default router %(2)y, mask %(3)y, sent by DHCP server %(4)y is unavailable likely allocated statically. DGS-3100 Series Gigabit Stackable Managed Switch User Manual ID SYSLG7.2.1 SEVERITY CATEGORY Warning Interface SYSLG7.2.2 SYSLG8.0.4 Warning Warning Interface IP SYSLG8.1.31 Warning....10.20 Warning bootup SYSLG8.10.21 Warning bootup SYSLG8.10.22 Warning DHCP SYSLG8.10.23 Warning DHCP SYSLG8.10.24 SYSLG8.10.25 Warning Warning DHCP bootup MESSAGE Port %(1)j removed from %(2)j: port is down/notPresent The specified port is ...
... memory is removed. BOOTP msg indicates that default router %(2)y, mask %(3)y, sent by DHCP server %(4)y is unavailable likely allocated statically. DGS-3100 Series Gigabit Stackable Managed Switch User Manual ID SYSLG7.2.1 SEVERITY CATEGORY Warning Interface SYSLG7.2.2 SYSLG8.0.4 Warning Warning Interface IP SYSLG8.1.31 Warning....10.20 Warning bootup SYSLG8.10.21 Warning bootup SYSLG8.10.22 Warning DHCP SYSLG8.10.23 Warning DHCP SYSLG8.10.24 SYSLG8.10.25 Warning Warning DHCP bootup MESSAGE Port %(1)j removed from %(2)j: port is down/notPresent The specified port is ...
Product Manual
Page 283
... and Thailand: Tel: +62-21-5731610 (Indonesia) Tel: 1800-882-880 (Malaysia) Tel: +65 6501 4200 (Singapore) Tel: +66-2-719-8978/9 (Thailand) 24/7, for English Support only Web: http://www.dlink.com.sg/support/ E-mail: [email protected] Korea: Tel: +82-2-2028-1815 Monday to Friday 9:00am... to 6:00pm Web: http://www.d-link.co.kr E-mail: arthur@d-link.co.kr New Zealand: Tel: 0800-900-900 24/7 Technical Support Web: http://www.dlink.co.nz E-mail: [email protected] Technical Support You can find software...
... and Thailand: Tel: +62-21-5731610 (Indonesia) Tel: 1800-882-880 (Malaysia) Tel: +65 6501 4200 (Singapore) Tel: +66-2-719-8978/9 (Thailand) 24/7, for English Support only Web: http://www.dlink.com.sg/support/ E-mail: [email protected] Korea: Tel: +82-2-2028-1815 Monday to Friday 9:00am... to 6:00pm Web: http://www.d-link.co.kr E-mail: arthur@d-link.co.kr New Zealand: Tel: 0800-900-900 24/7 Technical Support Web: http://www.dlink.co.nz E-mail: [email protected] Technical Support You can find software...