... mandatory if gap from back of cooktop to combustible wall is less than 2 1/2" (Figure 2). When installing a backguard, use only Dacor model numbers AEB3609, AEB3612 (EG366), AEB4809 or AEB4812 (EG486). Side View cabinet/countertop Side View with the accompanying installation instructions. Contact ...197 mm) 5/8" (16 mm) cabinet/countertop Side View without notice. Document # PG04-001 EG366, EG486 36 Inch and 48 Inch Wide Epicure® Gas Cooktops Revised 05/06/10 Page 1/4 PLANNING GUIDE warning • Observe all appliances according to accompanying installation instructions.
... mandatory if gap from back of cooktop to combustible wall is less than 2 1/2" (Figure 2). When installing a backguard, use only Dacor model numbers AEB3609, AEB3612 (EG366), AEB4809 or AEB4812 (EG486). Side View cabinet/countertop Side View with the accompanying installation instructions. Contact ...197 mm) 5/8" (16 mm) cabinet/countertop Side View without notice. Document # PG04-001 EG366, EG486 36 Inch and 48 Inch Wide Epicure® Gas Cooktops Revised 05/06/10 Page 1/4 PLANNING GUIDE warning • Observe all appliances according to accompanying installation instructions.
Planning Guides
Page 2
... 3 Not applicable for utility access Cabinet/Countertop Dimensions ISO View 1 Vertical to combustible side wall Min. Install all appliances according to change without notice. www.Dacor.com Phone: (800) 793-0093 4.2 EG366 EG486 B 36" (914 mm) 48" (1219mm) C 36" (914 mm)* 42" (1067 mm)** ... B 1 1/2" (38 mm) typical countertop thickness Cooktop platform 1" (25 mm) Min. EG366, EG486 Document # PG04-001 36 Inch and 48 Inch Wide Epicure® Gas Cooktops Cabinet tolerances: +1/16", -0 (+1.6 mm, -0) unless otherwise noted. 10" (254 mm) to combustible surface from the edge of 10"...
... 3 Not applicable for utility access Cabinet/Countertop Dimensions ISO View 1 Vertical to combustible side wall Min. Install all appliances according to change without notice. www.Dacor.com Phone: (800) 793-0093 4.2 EG366 EG486 B 36" (914 mm) 48" (1219mm) C 36" (914 mm)* 42" (1067 mm)** ... B 1 1/2" (38 mm) typical countertop thickness Cooktop platform 1" (25 mm) Min. EG366, EG486 Document # PG04-001 36 Inch and 48 Inch Wide Epicure® Gas Cooktops Cabinet tolerances: +1/16", -0 (+1.6 mm, -0) unless otherwise noted. 10" (254 mm) to combustible surface from the edge of 10"...
Planning Guides
Page 3
... all appliances according to change without Raised Vent - Top View Model No. Cutout Width 36" (914 mm) 48" (1219 mm) D - www.Dacor.com Phone: (800) 793-0093 4.3 Hole Offset 16 5/8" (422 mm) 20 13/16" (529 mm) Specifications subject to accompanying installation instructions. ...Document # PG04-001 EG366, EG486 36 Inch and 48 Inch Wide Epicure® Gas Cooktops Cutout tolerances: +1/16", -0, (+1.6 mm, -0) unless otherwise stated Revised 05/06/10 Page 3/4 PLANNING GUIDE Gas and electrical ...
... all appliances according to change without Raised Vent - Top View Model No. Cutout Width 36" (914 mm) 48" (1219 mm) D - www.Dacor.com Phone: (800) 793-0093 4.3 Hole Offset 16 5/8" (422 mm) 20 13/16" (529 mm) Specifications subject to accompanying installation instructions. ...Document # PG04-001 EG366, EG486 36 Inch and 48 Inch Wide Epicure® Gas Cooktops Cutout tolerances: +1/16", -0, (+1.6 mm, -0) unless otherwise stated Revised 05/06/10 Page 3/4 PLANNING GUIDE Gas and electrical ...
Planning Guides
Page 4
...13 mm) countertop overhang Countertop Countertop 2" (51 mm) 1" (25 mm) D D Cabinet face CL CL CL below to clear stiffener Dacor approved raised vent 3/8" Min. (10 mm) flat countertop overhang required behind raised vent chassis to allow for raised vent, gas and electrical ...connections 1" thick mounting platform Min. EG366, EG486 Document # PG04-001 36 Inch and 48 Inch Wide Epicure® Gas Cooktops Cutout tolerances: +1/16", -0, (+1.6 mm, -0) unless otherwise stated Revised 05/06/10 Page 4/4 PLANNING GUIDE 2 5/8" (67...
...13 mm) countertop overhang Countertop Countertop 2" (51 mm) 1" (25 mm) D D Cabinet face CL CL CL below to clear stiffener Dacor approved raised vent 3/8" Min. (10 mm) flat countertop overhang required behind raised vent chassis to allow for raised vent, gas and electrical ...connections 1" thick mounting platform Min. EG366, EG486 Document # PG04-001 36 Inch and 48 Inch Wide Epicure® Gas Cooktops Cutout tolerances: +1/16", -0, (+1.6 mm, -0) unless otherwise stated Revised 05/06/10 Page 4/4 PLANNING GUIDE 2 5/8" (67...
Installation Instructions
Page 1
N THIS APPLIANCE HAS BEEN TESTED IN ACCORDANCE WITH THE LATEST EDITION OF ANSI Z21.1 STANDARD FOR HOUSEHOLD GAS APPLIANCES. Installation Instructions Epicure® Cooktop Models: EG366, EG486 Part No. 102025 Rev.
N THIS APPLIANCE HAS BEEN TESTED IN ACCORDANCE WITH THE LATEST EDITION OF ANSI Z21.1 STANDARD FOR HOUSEHOLD GAS APPLIANCES. Installation Instructions Epicure® Cooktop Models: EG366, EG486 Part No. 102025 Rev.
Use & Care Manuals
Page 1
H Use and Care Manual Epicure® Cooktop Models: EG366, EG486 Ta b l e o f C o n t e n t s Important Safety Instructions 1-3 Getting to Know Your Cooktop 4 Setting Up Your Cooktop 5-6 Operating Your Cooktop 6-8 Care and Cleaning 10-11 Accessories and Replacement Parts 11 Before You Call For Service 12 Warranty and Service 13 Notes 14-16 Warranty Card Back Cover Part No. 102024 Rev.
H Use and Care Manual Epicure® Cooktop Models: EG366, EG486 Ta b l e o f C o n t e n t s Important Safety Instructions 1-3 Getting to Know Your Cooktop 4 Setting Up Your Cooktop 5-6 Operating Your Cooktop 6-8 Care and Cleaning 10-11 Accessories and Replacement Parts 11 Before You Call For Service 12 Warranty and Service 13 Notes 14-16 Warranty Card Back Cover Part No. 102024 Rev.