Planning Guides
Page 1
... to combustible wall is recessed 2" (51 mm) from back of cooktop to accompanying installation instructions. When installing a backguard, use only Dacor model numbers AEB3609, AEB3612 (EG366), AEB4809 or AEB4812 (EG486). iSO VIEW EG366 EG486 A - Side View cabinet/countertop Side View with...60 Hz Gas Supply Pressure Requirements* Gas Type Manifold Pressure Minimum Gas Supply Pressure Natural Gas 5" Water Column 6" Water Column Propane (LP) 10" Water Column 11" Water Column * Maximum gas supply pressure for further information. • This appliance must be installed in ...
... to combustible wall is recessed 2" (51 mm) from back of cooktop to accompanying installation instructions. When installing a backguard, use only Dacor model numbers AEB3609, AEB3612 (EG366), AEB4809 or AEB4812 (EG486). iSO VIEW EG366 EG486 A - Side View cabinet/countertop Side View with...60 Hz Gas Supply Pressure Requirements* Gas Type Manifold Pressure Minimum Gas Supply Pressure Natural Gas 5" Water Column 6" Water Column Propane (LP) 10" Water Column 11" Water Column * Maximum gas supply pressure for further information. • This appliance must be installed in ...
Installation Instructions
Page 2
.... Whenever you begin the installation process. The model and serial number are subject to specifications. © 2007 Dacor, all rights reserved. Friday 6:00 a.m. Model Identification EG366SCH/NG/H SIZE (in inches) GAS TYPE NG = Natural Gas LP = Liquid Petroleum (Propane) ALTITUDE H = High Altitude Model, 4000 ft.(1219 m) and up No character = Equipped for low...
.... Whenever you begin the installation process. The model and serial number are subject to specifications. © 2007 Dacor, all rights reserved. Friday 6:00 a.m. Model Identification EG366SCH/NG/H SIZE (in inches) GAS TYPE NG = Natural Gas LP = Liquid Petroleum (Propane) ALTITUDE H = High Altitude Model, 4000 ft.(1219 m) and up No character = Equipped for low...
Installation Instructions
Page 5
...ordinances during planning and installation. GAS SUPPLY PRESSURE REQUIREMENTS* Gas Type Manifold Pressure Minimum Gas Supply Pressure Natural Gas 5" Water Column 6" Water Column Propane (LP) 10" Water Column 11" Water Column * Maximum gas supply pressure for the gas service being provided (natural gas or... LP gas). Also, if operating the cooktop at an altitude above countertop 7 3/4" (197 mm) 4" (102 mm) Power cord 32" long 5/8" (16 mm) 3/4" gas inlet, ...
...ordinances during planning and installation. GAS SUPPLY PRESSURE REQUIREMENTS* Gas Type Manifold Pressure Minimum Gas Supply Pressure Natural Gas 5" Water Column 6" Water Column Propane (LP) 10" Water Column 11" Water Column * Maximum gas supply pressure for the gas service being provided (natural gas or... LP gas). Also, if operating the cooktop at an altitude above countertop 7 3/4" (197 mm) 4" (102 mm) Power cord 32" long 5/8" (16 mm) 3/4" gas inlet, ...
Installation Instructions
Page 11
... shut-off valve to the cooktop during any gas supply piping system pressure testing equal to or less than ½ psi (3.5 kPa). • For LP gas installations, the LP gas tank must be installed upstream from the gas supply piping system during any pressure test- ing exceeding ½ psi (3.5 kPa). • The...
... shut-off valve to the cooktop during any gas supply piping system pressure testing equal to or less than ½ psi (3.5 kPa). • For LP gas installations, the LP gas tank must be installed upstream from the gas supply piping system during any pressure test- ing exceeding ½ psi (3.5 kPa). • The...
Use & Care Manuals
Page 9
... the burner knob to the HIGH position. Always check the position of the burner while the igniter is off when you are normal when using LP gas. • If the flame is not even around the burner cap. Eliminate any part of the control knobs to the desired level by... Dacor's Smart-Flame feature. Doing so may continue to the surrounding area. • Do not touch any drafts or reduce the ventilation blower speed to cook. ...
... the burner knob to the HIGH position. Always check the position of the burner while the igniter is off when you are normal when using LP gas. • If the flame is not even around the burner cap. Eliminate any part of the control knobs to the desired level by... Dacor's Smart-Flame feature. Doing so may continue to the surrounding area. • Do not touch any drafts or reduce the ventilation blower speed to cook. ...
Use & Care Manuals
Page 14
... more information on how to minimize. ting. Make sure burner is assembled according tioned. the gas regulator. Check for the type of gas (Natural or LP) or set up to use a different type of gas and the correct altitude. May Be Caused By Cooktop not connected to Care and Cleaning section...
... more information on how to minimize. ting. Make sure burner is assembled according tioned. the gas regulator. Check for the type of gas (Natural or LP) or set up to use a different type of gas and the correct altitude. May Be Caused By Cooktop not connected to Care and Cleaning section...