Planning Guides
Page 1
...Min.* (63.5 cm) * Height above cooking surface. The minimum specified distance may be higher for the cooktop or range. www.Dacor.com Phone: (800) 793-0093 7.4 Check the manufacturers specifications for the particular range or cooktop in accordance with the accompanying installation ... D B E Overall Dimensions Electrical access Model EH/EHR3012 EH/EHR3612 EH/EHR4212 EH/EHR4812 MH3012 MH3612 MH4812 EH/EHR3018 EH/EHR3618 EH/EHR4218 EH/EHR4818 EH/EHR5418 MH3018 MH3618 MH4818 Overall Dimensions A B 29 7/8" (75.9 cm) 35 7/8" (91.1 cm) 41 7/8" (106.4 cm) 26 7/8" (68.3 cm) 47 7/8" (...
...Min.* (63.5 cm) * Height above cooking surface. The minimum specified distance may be higher for the cooktop or range. www.Dacor.com Phone: (800) 793-0093 7.4 Check the manufacturers specifications for the particular range or cooktop in accordance with the accompanying installation ... D B E Overall Dimensions Electrical access Model EH/EHR3012 EH/EHR3612 EH/EHR4212 EH/EHR4812 MH3012 MH3612 MH4812 EH/EHR3018 EH/EHR3618 EH/EHR4218 EH/EHR4818 EH/EHR5418 MH3018 MH3618 MH4818 Overall Dimensions A B 29 7/8" (75.9 cm) 35 7/8" (91.1 cm) 41 7/8" (106.4 cm) 26 7/8" (68.3 cm) 47 7/8" (...
Planning Guides
Page 2
...) EHR3618 48 lbs. (22 kg) EHR4212 46 lbs. (21 kg) EHR4218 51 lbs. (23 kg) EHR4812 52 lbs. (24 kg) EHR4818 59 lbs. (27 kg) EHR5418 66.4 lbs. (30 kg) Duct Size 8" round 10" round 3¼" X 10" rectangular Maximum Straight Duct Run 60 feet 50 feet 50 feet IMPORTANT: When planning... the installation, you must calculate the actual length the duct work cannot exceed. www.Dacor.com Phone: (800) 793-0093 7.5 surge) 120 Vac, 75 W halogen 120 Vac, 15 Amp. To calculate actual maximum duct length, use the above specifications in...
...) EHR3618 48 lbs. (22 kg) EHR4212 46 lbs. (21 kg) EHR4218 51 lbs. (23 kg) EHR4812 52 lbs. (24 kg) EHR4818 59 lbs. (27 kg) EHR5418 66.4 lbs. (30 kg) Duct Size 8" round 10" round 3¼" X 10" rectangular Maximum Straight Duct Run 60 feet 50 feet 50 feet IMPORTANT: When planning... the installation, you must calculate the actual length the duct work cannot exceed. www.Dacor.com Phone: (800) 793-0093 7.5 surge) 120 Vac, 75 W halogen 120 Vac, 15 Amp. To calculate actual maximum duct length, use the above specifications in...
Installation Instructions
Page 35
... 41 7/8" (106.4 cm) EHR3018 29 7/8" (75.9 cm) EHR3618 35 7/8" (91.1 cm) 26 7/8" 18" 6 1/8" (68.3 cm) (45.7 cm) (15.6 cm) EHR4818 47 7/8" (121.6 cm) EHR5418 53 7/8 (136.8 cm) *** See diagram on facing page. 2" (5.1 cm) 32" (81.3 cm) Dimensions of Optional AHT10 Transition For dual exhaust models, See page 7 for more...) •D Light replacement tool • B 2 temporary mounting brackets •E Literature • C Temporary mounting hardware •F Light bulbs (quantity varies with model) •G Dacor Stainless Steel Cleaner A D E F G B C STAINLESS STEEL CLEANER 5
... 41 7/8" (106.4 cm) EHR3018 29 7/8" (75.9 cm) EHR3618 35 7/8" (91.1 cm) 26 7/8" 18" 6 1/8" (68.3 cm) (45.7 cm) (15.6 cm) EHR4818 47 7/8" (121.6 cm) EHR5418 53 7/8 (136.8 cm) *** See diagram on facing page. 2" (5.1 cm) 32" (81.3 cm) Dimensions of Optional AHT10 Transition For dual exhaust models, See page 7 for more...) •D Light replacement tool • B 2 temporary mounting brackets •E Literature • C Temporary mounting hardware •F Light bulbs (quantity varies with model) •G Dacor Stainless Steel Cleaner A D E F G B C STAINLESS STEEL CLEANER 5