... behind control panel (D)** Chassis Height 27 1/2" (69.9 cm) 27 1/4" (69.2 cm) (E) Control Panel Overlay 15/16" (23.8 cm) 7/8" (2.2 cm) Model Number EORS127 MORS127 EORS130 MORS130 EORS136 Dedicated Circuit Requirements 240 Vac 60 Hz., 4-wire***, 30 Amp. Total Connected Load 5.0 kW (20.8 Amp.) 5.3 kW (22 Amp.) *** Two 120 Vac hot (L1 and...accompanying installation instructions. Contact your local building department for further information. • This appliance must be installed in accordance with the accompanying installation instructions. www.Dacor.com Phone: (800) 793-0093 1.1
... behind control panel (D)** Chassis Height 27 1/2" (69.9 cm) 27 1/4" (69.2 cm) (E) Control Panel Overlay 15/16" (23.8 cm) 7/8" (2.2 cm) Model Number EORS127 MORS127 EORS130 MORS130 EORS136 Dedicated Circuit Requirements 240 Vac 60 Hz., 4-wire***, 30 Amp. Total Connected Load 5.0 kW (20.8 Amp.) 5.3 kW (22 Amp.) *** Two 120 Vac hot (L1 and...accompanying installation instructions. Contact your local building department for further information. • This appliance must be installed in accordance with the accompanying installation instructions. www.Dacor.com Phone: (800) 793-0093 1.1
Planning Guides
Page 2
...location R P 3/4" (1.9 cm) support platform Model Number (N) Minimum Cabinet Width (P) Minimum Cut Out Width (R) Minimum Cut out Height EORS127/ MORS127 EORS130/ MORS130 EORS136 27" (68.6 cm) 30" (76.2 cm) 36" (91.4 cm) 25 ½" (64.8 cm) 28 ½" (72.4 cm)) 34...) Min. to bottom of cabinet door Alternate electrical location 31 1/4" (79.4 cm) recommended 4" typical toe kick Single Wall Oven - www.Dacor.com Phone: (800) 793-0093 1.2 N support platform to accompanying installation instructions. to change without notice. Cut Out Dimensions Specifications subject to ...
...location R P 3/4" (1.9 cm) support platform Model Number (N) Minimum Cabinet Width (P) Minimum Cut Out Width (R) Minimum Cut out Height EORS127/ MORS127 EORS130/ MORS130 EORS136 27" (68.6 cm) 30" (76.2 cm) 36" (91.4 cm) 25 ½" (64.8 cm) 28 ½" (72.4 cm)) 34...) Min. to bottom of cabinet door Alternate electrical location 31 1/4" (79.4 cm) recommended 4" typical toe kick Single Wall Oven - www.Dacor.com Phone: (800) 793-0093 1.2 N support platform to accompanying installation instructions. to change without notice. Cut Out Dimensions Specifications subject to ...
Installation Instructions
Page 8
... location. Make certain that allows the oven to be used as indicated. There are met or exceeded. Installation Specifications Installation Planning • Dacor recommends installing the electrical junction box in the one of convection ovens, see page 3 Minimum Cut out Height (R) 27 5/8" (70.2 ...of the cabinet. warning Observe all minimum clearances are no provisions to be provided. Proper installation is recommended. Model Number EORS127/ MORS127 EORS130/ MOCS130 EORS136 EORX227/ MORX227 Minimum Cabinet Width (N) 27" (68.6 cm) 30" (76.2 cm) 36" (91.4 cm) 27" (68.6 cm...
... location. Make certain that allows the oven to be used as indicated. There are met or exceeded. Installation Specifications Installation Planning • Dacor recommends installing the electrical junction box in the one of convection ovens, see page 3 Minimum Cut out Height (R) 27 5/8" (70.2 ...of the cabinet. warning Observe all minimum clearances are no provisions to be provided. Proper installation is recommended. Model Number EORS127/ MORS127 EORS130/ MOCS130 EORS136 EORX227/ MORX227 Minimum Cabinet Width (N) 27" (68.6 cm) 30" (76.2 cm) 36" (91.4 cm) 27" (68.6 cm...
Installation Instructions
Page 10
...manual • Exhaust grill with 2 mounting screws (2, #8 X 3/8", • Mounting screws (Wood, #6 X ¾, Dacor PN 83331, 4 for single ovens, 6 for removing door from model EORS136. 1. The hinge springs could release, causing personal injury. • Do not lift or carry oven door by the door... Removing the Oven Door(s): All Models Except EORS136 See facing page for double ovens) color should match exhaust grill: Silver Dacor PN 83571, Black Dacor PN 83263) • Standard oven racks (single ovens come with 2, double • Dacor Stainless Steel Cleaner ovens come with either 4...
...manual • Exhaust grill with 2 mounting screws (2, #8 X 3/8", • Mounting screws (Wood, #6 X ¾, Dacor PN 83331, 4 for single ovens, 6 for removing door from model EORS136. 1. The hinge springs could release, causing personal injury. • Do not lift or carry oven door by the door... Removing the Oven Door(s): All Models Except EORS136 See facing page for double ovens) color should match exhaust grill: Silver Dacor PN 83571, Black Dacor PN 83263) • Standard oven racks (single ovens come with 2, double • Dacor Stainless Steel Cleaner ovens come with either 4...
Installation Instructions
Page 16
... and check the electrical connections. • Turn on power and repeat the above heating test. • If the appliance still does not work, contact Dacor Distinctive Service at a 15° angle with one hand while pushing in on each of the bottom corners of the door. Slide the oven racks... for both the upper and lower ovens. 6. Installation Instructions Reinstalling the Oven Door (Cont) Verifying Proper Operation To re-install the oven door on model EORS136: warning To avoid personal injury or damage to the door from it falling off its hinges: • Make sure that the notch on the bottom...
... and check the electrical connections. • Turn on power and repeat the above heating test. • If the appliance still does not work, contact Dacor Distinctive Service at a 15° angle with one hand while pushing in on each of the bottom corners of the door. Slide the oven racks... for both the upper and lower ovens. 6. Installation Instructions Reinstalling the Oven Door (Cont) Verifying Proper Operation To re-install the oven door on model EORS136: warning To avoid personal injury or damage to the door from it falling off its hinges: • Make sure that the notch on the bottom...