... exceed the maximums stated at the right. ■■ The maximum straight duct length for wind resistance. ERV/PRV30 ERV/PRV36 PRV46 ERV48 Approved Dacor Blowers* Remote blowers: REMP3 or REMP16 In-line blowers: ILHSF8 or ILHSF10 For example, for a raised vent system using 3 1/4" X 10" rectangular duct, two (2) ...feet 3 ¼" X 10 to as few sharp angles as possible. ■■ For best performance, use flexible metal duct. Document # PG08-001 ERV30, ERV36, ERV48, PRV30, PRV36, PRV46 30", 36", 46", 48" Wide, Slim Raised Vent Revised 03/29/10 Page 2/3 PLANNING GUIDE Duct Work...
... exceed the maximums stated at the right. ■■ The maximum straight duct length for wind resistance. ERV/PRV30 ERV/PRV36 PRV46 ERV48 Approved Dacor Blowers* Remote blowers: REMP3 or REMP16 In-line blowers: ILHSF8 or ILHSF10 For example, for a raised vent system using 3 1/4" X 10" rectangular duct, two (2) ...feet 3 ¼" X 10 to as few sharp angles as possible. ■■ For best performance, use flexible metal duct. Document # PG08-001 ERV30, ERV36, ERV48, PRV30, PRV36, PRV46 30", 36", 46", 48" Wide, Slim Raised Vent Revised 03/29/10 Page 2/3 PLANNING GUIDE Duct Work...
Installation Instructions
Page 8
...; To reduce the risk of fire and to properly exhaust air, be sure to duct air outside . APPROVED DACOR BLOWERS FOR USE WITH MODEL ERV AND PRV SERIES RAISED VENTS Model Number REMP3 REMP16 ILHSF8 ILHSF10 Rating* 600 CFM 1000 CFM 600 CFM 1100 CFM • When connecting the duct work to... vertical center line of bottom knock- • Do not rely on raised vent 26" (66.0 cm) 1 1/8" (2.9 cm) 6 1/4" CL (15.9 cm) Front of the Dacor remote or in the floor to allow the transition and/or duct work to prevent combustion by the raised vent.
...; To reduce the risk of fire and to properly exhaust air, be sure to duct air outside . APPROVED DACOR BLOWERS FOR USE WITH MODEL ERV AND PRV SERIES RAISED VENTS Model Number REMP3 REMP16 ILHSF8 ILHSF10 Rating* 600 CFM 1000 CFM 600 CFM 1100 CFM • When connecting the duct work to... vertical center line of bottom knock- • Do not rely on raised vent 26" (66.0 cm) 1 1/8" (2.9 cm) 6 1/4" CL (15.9 cm) Front of the Dacor remote or in the floor to allow the transition and/or duct work to prevent combustion by the raised vent.
Installation Instructions
Page 9
... to 8" round transition 25 feet 3 ¼" X 10 to as few sharp angles as much space between them. Duct Size Used 8 Inch 10 Inch 3 ¼" X 10" REMP3 Remote Blower 50 feet (15.2 meters) 40 feet (12.2 meters) 40 feet (12.2 meters) Blower Maximum Duct Straight Length REMP16 Remote Blower ILHSF8 In-line...
... to 8" round transition 25 feet 3 ¼" X 10 to as few sharp angles as much space between them. Duct Size Used 8 Inch 10 Inch 3 ¼" X 10" REMP3 Remote Blower 50 feet (15.2 meters) 40 feet (12.2 meters) 40 feet (12.2 meters) Blower Maximum Duct Straight Length REMP16 Remote Blower ILHSF8 In-line...
Installation Instructions
Page 8
... draw by the raised vent. The ERV raised vent can increase the duct size over the run. APPROVED DACOR BLOWERS FOR USE WITH MODEL ERV36-ER AND ERV48-ER RAISED VENTS Model Number REMP3 REMP16 ILHSF8 ILHSF10 Rating* 600 CFM 1000 CFM 600 CFM 1100 CFM plied ATD2 transition to connect the... desired. Do not rely on duct tape alone to make the connection. To prevent back-drafts, a damper at zero inches static pressure. one of the Dacor remote or in the floor to allow the transition and/or duct work to prevent combustion by-products, smoke or odors from entering the home...
... draw by the raised vent. The ERV raised vent can increase the duct size over the run. APPROVED DACOR BLOWERS FOR USE WITH MODEL ERV36-ER AND ERV48-ER RAISED VENTS Model Number REMP3 REMP16 ILHSF8 ILHSF10 Rating* 600 CFM 1000 CFM 600 CFM 1100 CFM plied ATD2 transition to connect the... desired. Do not rely on duct tape alone to make the connection. To prevent back-drafts, a damper at zero inches static pressure. one of the Dacor remote or in the floor to allow the transition and/or duct work to prevent combustion by-products, smoke or odors from entering the home...
Installation Instructions
Page 9
... number of elbows and transitions used with as far away from the Blower Maximum Duct Straight Length. Duct Size Used 8 Inch 10 Inch 3 ¼" X 10" REMP3 Remote Blower 50 feet (15.2 meters) 40 feet (12.2 meters) 40 feet (12.2 meters) Blower Maximum Duct Straight Length REMP16 Remote Blower ILHSF8 In-line...
... number of elbows and transitions used with as far away from the Blower Maximum Duct Straight Length. Duct Size Used 8 Inch 10 Inch 3 ¼" X 10" REMP3 Remote Blower 50 feet (15.2 meters) 40 feet (12.2 meters) 40 feet (12.2 meters) Blower Maximum Duct Straight Length REMP16 Remote Blower ILHSF8 In-line...