Planning Guides
Page 1
... Intake Collar Discharge REMP16 overall dimensions (Top & Side Views) Model No. REMP3 REMP16 Electrical Supply Requirments Refer to raised vent or hood specifications Web: http://www.Dacor.com Corporate Phone: 800-793-0093 Maximum Duct Length Refer to change without ...120 Vac, 2.7 Amp Blower Rating* 600 CFM (nominal) 620.5 CFM (actual) 1000 CFM (nominal) 994.8 CFM (actual) Approximate Shipping Weight 35 lbs. 55 lbs. See installation instructions for further information. 2. Contact your local building department for additional details. 9.3 REMP3, REMP16 Revised 01/30/09 Remote ...
... Intake Collar Discharge REMP16 overall dimensions (Top & Side Views) Model No. REMP3 REMP16 Electrical Supply Requirments Refer to raised vent or hood specifications Web: http://www.Dacor.com Corporate Phone: 800-793-0093 Maximum Duct Length Refer to change without ...120 Vac, 2.7 Amp Blower Rating* 600 CFM (nominal) 620.5 CFM (actual) 1000 CFM (nominal) 994.8 CFM (actual) Approximate Shipping Weight 35 lbs. 55 lbs. See installation instructions for further information. 2. Contact your local building department for additional details. 9.3 REMP3, REMP16 Revised 01/30/09 Remote ...
Planning Guides
Page 2
inches of water REMP16 Blower Performance 2.5 2.0 1.5 1.0 0.5 0 200 400 600 800 1000 Airflow CFM (Cubic feet/minute) Web: http://www.Dacor.com Corporate Phone: 800-793-0093 Specifications are subject to change without notice. See installation instructions for additional details. 9.4 Revised 01/30/09 REMP3, REMP16 Remote Blowers PLANNING 2/3 GUIDE Static pressure - inches of water REMP3 Blower Performance 5.0 4.0 3.0 2.0 1.0 0 100 200 300 400 500 600 700 Airflow CFM (Cubic feet/minute) Static pressure -
inches of water REMP16 Blower Performance 2.5 2.0 1.5 1.0 0.5 0 200 400 600 800 1000 Airflow CFM (Cubic feet/minute) Web: http://www.Dacor.com Corporate Phone: 800-793-0093 Specifications are subject to change without notice. See installation instructions for additional details. 9.4 Revised 01/30/09 REMP3, REMP16 Remote Blowers PLANNING 2/3 GUIDE Static pressure - inches of water REMP3 Blower Performance 5.0 4.0 3.0 2.0 1.0 0 100 200 300 400 500 600 700 Airflow CFM (Cubic feet/minute) Static pressure -
Installation Instructions
Page 6
...blower. Duct and wiring passing through the wall or roof into the blower assembly. Model Number* REMP3 REMP16 Power Requirements** 120 Vac, 60 Hz, 3.8 Amp 120 Vac, 60 Hz, 2.7 Amp Blower Rating*** 600 CFM 1000 CFM * All models are for reference only, See the data label on the other. The above ... included) by a 1/2" UL certified strain relief. Connect the wiring/ conduit to the raised vent or hood on each end by an approved Dacor hood or raised vent. The wiring/conduit is installed between blower air flow rates can greatly reduce the air draw by routing wiring/ conduit parallel...
...blower. Duct and wiring passing through the wall or roof into the blower assembly. Model Number* REMP3 REMP16 Power Requirements** 120 Vac, 60 Hz, 3.8 Amp 120 Vac, 60 Hz, 2.7 Amp Blower Rating*** 600 CFM 1000 CFM * All models are for reference only, See the data label on the other. The above ... included) by a 1/2" UL certified strain relief. Connect the wiring/ conduit to the raised vent or hood on each end by an approved Dacor hood or raised vent. The wiring/conduit is installed between blower air flow rates can greatly reduce the air draw by routing wiring/ conduit parallel...
Installation Instructions
Page 10
inches of water 4.0 2.0 3.0 1.5 2.0 1.0 1.0 0 100 200 300 400 500 600 700 Airflow CFM (Cubic feet/minute) 0.5 0 200 400 600 800 1000 Airflow CFM (Cubic feet/minute) 8 inches of water Static pressure - Technical Data REMP Series Blower Ratings Model Number REMP3 REMP16 Nominal Rating* 600 CFM 1000 CFM * At 0" static pressure Actual Rating* 620.5 CFM 994.8 CFM REMP3 Blower Performance 5.0 REMP16 Blower Performance 2.5 Static pressure -
inches of water 4.0 2.0 3.0 1.5 2.0 1.0 1.0 0 100 200 300 400 500 600 700 Airflow CFM (Cubic feet/minute) 0.5 0 200 400 600 800 1000 Airflow CFM (Cubic feet/minute) 8 inches of water Static pressure - Technical Data REMP Series Blower Ratings Model Number REMP3 REMP16 Nominal Rating* 600 CFM 1000 CFM * At 0" static pressure Actual Rating* 620.5 CFM 994.8 CFM REMP3 Blower Performance 5.0 REMP16 Blower Performance 2.5 Static pressure -