... of physical disks (LUNs). This roadmap is intended for CX-Series and FC-Series Storage Systems vii Preface Audience This manual contains checklists of the tasks required to install an EMC CX-Series or FC4700-Series storage system in a configuration with the following topics: ◆ The operating system running the... be supported by all revisions of the software or hardware currently in use by system administrators and/or service personnel during installation of CLARiiON® Fibre Channel storage systems. Readers of this roadmap, please contact your product release notes.
... of physical disks (LUNs). This roadmap is intended for CX-Series and FC-Series Storage Systems vii Preface Audience This manual contains checklists of the tasks required to install an EMC CX-Series or FC4700-Series storage system in a configuration with the following topics: ◆ The operating system running the... be supported by all revisions of the software or hardware currently in use by system administrators and/or service personnel during installation of CLARiiON® Fibre Channel storage systems. Readers of this roadmap, please contact your product release notes.
Installation Guide
Page 165
...the HBAs until you PowerPath product must either load the PowerPath driver manually or remove all redundant guide paths. PowerPath release Note After PowerPath is installed on the EMC Powerlink website: http://powerlink.emc.com 4 Server ❑ Install the Navisphere Host Agent or ...Navisphere Server Utility and the Install Host Navisphere CLI. Agent or Server Utility CX-Series Server Software for CLARiiON and PowerPath. Task With Access...
...the HBAs until you PowerPath product must either load the PowerPath driver manually or remove all redundant guide paths. PowerPath release Note After PowerPath is installed on the EMC Powerlink website: http://powerlink.emc.com 4 Server ❑ Install the Navisphere Host Agent or ...Navisphere Server Utility and the Install Host Navisphere CLI. Agent or Server Utility CX-Series Server Software for CLARiiON and PowerPath. Task With Access...
Installation Guide
Page 209
...the following command: vxddladm addjbod vid=DGC pagecode 0x83 offset=8 length=16 You need to set volume_open_policy=firstpath" VERITAS VxVM documentation and EMC manual on installing and configuring EMP power devices with a license key (cont.) ❑ Start I/O to the LUN. ❑ Identify ...the HBA sending I/O to LUN by CLARiiON storage systems will take effect. PowerPath Checklist - Solaris Installation Checklists Task With Access Logix Reference Document 18 Server Test PowerPath with Solaris...
...the following command: vxddladm addjbod vid=DGC pagecode 0x83 offset=8 length=16 You need to set volume_open_policy=firstpath" VERITAS VxVM documentation and EMC manual on installing and configuring EMP power devices with a license key (cont.) ❑ Start I/O to the LUN. ❑ Identify ...the HBA sending I/O to LUN by CLARiiON storage systems will take effect. PowerPath Checklist - Solaris Installation Checklists Task With Access Logix Reference Document 18 Server Test PowerPath with Solaris...
Installation Guide
Page 220
..., on the next reboot. You are now ready to set volume_open_policy=firstpath" On the next reboot, the first path policy used by CLARiiON storage systems will take effect. Solaris Installation Checklists Task With Access Logix Without Access Logix Reference Document 16 Server Test PowerPath with a license...lines to the bottom of the file after the last fi character: VERITAS VxVM documentation and EMC manual on the next reboot. On the next reboot, the first path policy used by CLARiiON storage systems will take effect. You need to issue this command just once and it ...
..., on the next reboot. You are now ready to set volume_open_policy=firstpath" On the next reboot, the first path policy used by CLARiiON storage systems will take effect. Solaris Installation Checklists Task With Access Logix Without Access Logix Reference Document 16 Server Test PowerPath with a license...lines to the bottom of the file after the last fi character: VERITAS VxVM documentation and EMC manual on the next reboot. On the next reboot, the first path policy used by CLARiiON storage systems will take effect. You need to issue this command just once and it ...
Installation Guide
Page 227
VERITAS VxVM documentation and EMC manual on installing and configuring EMP power devices with Solaris applications For a server with VERITAS VxVM V3.1.1 or below ❑ Before you reboot the server, edit ... Solaris Server and New Storage System 5-31 You are now ready to set volume_open_policy=firstpath" On the next reboot, the first path policy used by CLARiiON storage systems will take effect. PowerPath Checklist - Solaris Installation Checklists Task 20 Server VERITAS VxVM With Access Logix Reference Document For a server with VERITAS VxVM...
VERITAS VxVM documentation and EMC manual on installing and configuring EMP power devices with Solaris applications For a server with VERITAS VxVM V3.1.1 or below ❑ Before you reboot the server, edit ... Solaris Server and New Storage System 5-31 You are now ready to set volume_open_policy=firstpath" On the next reboot, the first path policy used by CLARiiON storage systems will take effect. PowerPath Checklist - Solaris Installation Checklists Task 20 Server VERITAS VxVM With Access Logix Reference Document For a server with VERITAS VxVM...
Installation Guide
Page 240
... the server, edit the /etc/rcS.d/S24powerstartup file to add the following two lines to the bottom of the file after the last fi character: EMC manual on installing and configuring EMP power devices with VERITAS VxVM V3.2 or above V3.2 or above ❑ Issue the following command: ❑ Issue ...volume_open_policy=firstpath echo "PowerPath:powermt set volume_open_policy=firstpath" echo "PowerPath:powermt set volume_open_policy=firstpath" On the next reboot, the first path policy used by CLARiiON storage systems will take effect. On the next reboot, the first path policy used by...
... the server, edit the /etc/rcS.d/S24powerstartup file to add the following two lines to the bottom of the file after the last fi character: EMC manual on installing and configuring EMP power devices with VERITAS VxVM V3.2 or above V3.2 or above ❑ Issue the following command: ❑ Issue ...volume_open_policy=firstpath echo "PowerPath:powermt set volume_open_policy=firstpath" echo "PowerPath:powermt set volume_open_policy=firstpath" On the next reboot, the first path policy used by CLARiiON storage systems will take effect. On the next reboot, the first path policy used by...
Installation Guide
Page 322
...LUNs. The server does not lose access to crash. ◆ The Navisphere Host Agent does not register host information with the storage system correctly. 7-64 EMC Installation Roadmap for CX-Series and FC-Series Storage Systems If you want the other SP to own any LUNs for load balancing, you must... manually transfer ownership of (trespass) those LUNs back to the SP using the Navisphere Manager or CLI. ◆ Windows DMP for CLARiiON does not support auto-restore for LUNs. If a failure occurs in a path to an SP...
...LUNs. The server does not lose access to crash. ◆ The Navisphere Host Agent does not register host information with the storage system correctly. 7-64 EMC Installation Roadmap for CX-Series and FC-Series Storage Systems If you want the other SP to own any LUNs for load balancing, you must... manually transfer ownership of (trespass) those LUNs back to the SP using the Navisphere Manager or CLI. ◆ Windows DMP for CLARiiON does not support auto-restore for LUNs. If a failure occurs in a path to an SP...