Calibration Guide
Page 2
... for importation costs of repair/replacement parts when product purchased in one country is submitted for repair in another country. Fluke warrants that software will be error free or operate without interruption. Warranty support is available only if product is three years and begins ..., to refund of the purchase price, free of charge repair, or replacement of operation or handling. If Fluke determines that software will operate substantially in transit. FLUKE SHALL NOT BE LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES, INCLUDING LOSS OF DATA, ...
... for importation costs of repair/replacement parts when product purchased in one country is submitted for repair in another country. Fluke warrants that software will be error free or operate without interruption. Warranty support is available only if product is three years and begins ..., to refund of the purchase price, free of charge repair, or replacement of operation or handling. If Fluke determines that software will operate substantially in transit. FLUKE SHALL NOT BE LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES, INCLUDING LOSS OF DATA, ...
Calibration Guide
Page 18
.../laptop Transfer screen dumps (bitmaps), settings and data using OC4USB optically isolated USB adapter/cable, (optional), using FlukeView® ScopeMeter® software for Windows®. Environmental Environmental MIL-PRF-28800F, Class 2 Temperature Operating and charging 0 °C to 40 °C (32 °... to 60 °C (-4 °F to PC/laptop, tablet, smartphone, etc. A USB port is provided for safety reasons. 123B/124B/125B Calibration Manual Miscellaneous Display Type 5.7-inch color active matrix TFT Resolution 640 pixels x 480 pixels Waveform Display Vertical 10 div of 40 ...
.../laptop Transfer screen dumps (bitmaps), settings and data using OC4USB optically isolated USB adapter/cable, (optional), using FlukeView® ScopeMeter® software for Windows®. Environmental Environmental MIL-PRF-28800F, Class 2 Temperature Operating and charging 0 °C to 40 °C (32 °... to 60 °C (-4 °F to PC/laptop, tablet, smartphone, etc. A USB port is provided for safety reasons. 123B/124B/125B Calibration Manual Miscellaneous Display Type 5.7-inch color active matrix TFT Resolution 640 pixels x 480 pixels Waveform Display Vertical 10 div of 40 ...
Calibration Guide
Page 54
... Case N Magnetic Hanger O FlukeView® ScopeMeter® Software for Windows® P Screen Protector G Banana-to order parts. 123B/124B/125B Calibration Manual Table 19. Table 20. XW Warning For safe operation and maintenance of two) C120B Fluke-1730-Hanger SW90W SP120B User-replaceable parts are listed in... Test Adapter: connects the probe tip to busses that use a DB9, RJ-45, or a M12 connector Software & Cable Carrying Case Kit (Supplied with Fluke 12x/S) Set contains the following parts: M Soft Carrying Case N Magnetic Hanger O FlukeView® ScopeMeter®...
... Case N Magnetic Hanger O FlukeView® ScopeMeter® Software for Windows® P Screen Protector G Banana-to order parts. 123B/124B/125B Calibration Manual Table 19. Table 20. XW Warning For safe operation and maintenance of two) C120B Fluke-1730-Hanger SW90W SP120B User-replaceable parts are listed in... Test Adapter: connects the probe tip to busses that use a DB9, RJ-45, or a M12 connector Software & Cable Carrying Case Kit (Supplied with Fluke 12x/S) Set contains the following parts: M Soft Carrying Case N Magnetic Hanger O FlukeView® ScopeMeter®...
User Manual
Page 2
..., then send the product to that service center, with its functional specifications for 90 days and that software will be error free or operate without interruption. Fluke warrants that it has been properly recorded on new and unused products to end-user customers only but...is submitted for damage in accordance with a description of the difficulty, postage and insurance prepaid (FOB Destination). If Fluke determines that software will be returned to a Fluke authorized service center within the warranty period. THIS WARRANTY IS BUYER'S SOLE AND EXCLUSIVE REMEDY AND IS IN LIEU ...
..., then send the product to that service center, with its functional specifications for 90 days and that software will be error free or operate without interruption. Fluke warrants that it has been properly recorded on new and unused products to end-user customers only but...is submitted for damage in accordance with a description of the difficulty, postage and insurance prepaid (FOB Destination). If Fluke determines that software will be returned to a Fluke authorized service center within the warranty period. THIS WARRANTY IS BUYER'S SOLE AND EXCLUSIVE REMEDY AND IS IN LIEU ...
User Manual
Page 15
...Packing List Item D E F G H I J K L M N O P Description Fluke Test Tool Rechargeable Li-ion Battery Pack Switch Mode Power Supply, Adapter/Battery Charger Shielded Test Leads with Black Ground Leads Test...USB Angled Adapter WiFi USB Adapter Soft Carrying Case Magnetic Hanger FlukeView ScopeMeter Software for Windows Screen Protector 12x-B 12x-B/S 123B, 124B or 125B x1) • 123B/S, 124B/S or 125B/S x2) • 124B, 125B 125B • 124B/S, 125B/S 125B • depends on version 5 Table 2. Industrial ScopeMeter® Test ...
...Packing List Item D E F G H I J K L M N O P Description Fluke Test Tool Rechargeable Li-ion Battery Pack Switch Mode Power Supply, Adapter/Battery Charger Shielded Test Leads with Black Ground Leads Test...USB Angled Adapter WiFi USB Adapter Soft Carrying Case Magnetic Hanger FlukeView ScopeMeter Software for Windows Screen Protector 12x-B 12x-B/S 123B, 124B or 125B x1) • 123B/S, 124B/S or 125B/S x2) • 124B, 125B 125B • 124B/S, 125B/S 125B • depends on version 5 Table 2. Industrial ScopeMeter® Test ...
User Manual
Page 69
...13. Communication The Test Tool can communicate with: • PC or laptop that uses FlukeView® ScopeMeter® software with an optical cable or wireless interface • Tablet or smartphone using Fluke Connect with WiFi interface Optical Interface Connect the Test Tool to a computer with a wired connection that can connect ...the battery door. 59 Wireless Interface You can be closed to insert a WiFi USB adapter. For more information about FlukeView® ScopeMeter® software, see the FlukeView documentation. Industrial ScopeMeter® Communication 2 1 Figure 13.
...13. Communication The Test Tool can communicate with: • PC or laptop that uses FlukeView® ScopeMeter® software with an optical cable or wireless interface • Tablet or smartphone using Fluke Connect with WiFi interface Optical Interface Connect the Test Tool to a computer with a wired connection that can connect ...the battery door. 59 Wireless Interface You can be closed to insert a WiFi USB adapter. For more information about FlukeView® ScopeMeter® software, see the FlukeView documentation. Industrial ScopeMeter® Communication 2 1 Figure 13.
User Manual
Page 76
...DB9, RJ-45, or a M12 connector Software & Cable Carrying Case Kit (Supplied with Fluke 12x/S) Set contains the following parts: • Screen Protector • Magnetic Hanger • Soft Carrying Case • FlukeView® ScopeMeter® Software for Windows® Banana-to-... Case Magnetic Hanger FlukeView® ScopeMeter® Software for Windows® Screen Protector Order Code BHT190 SCC 120B SP120B Fluke-1730-Hanger C120B SW90W BB120-II (set of two) C120B Fluke-1730-Hanger SW90W SP120B 66 123B/124B/125B Users Manual Item (see Figure 1) not...
...DB9, RJ-45, or a M12 connector Software & Cable Carrying Case Kit (Supplied with Fluke 12x/S) Set contains the following parts: • Screen Protector • Magnetic Hanger • Soft Carrying Case • FlukeView® ScopeMeter® Software for Windows® Banana-to-... Case Magnetic Hanger FlukeView® ScopeMeter® Software for Windows® Screen Protector Order Code BHT190 SCC 120B SP120B Fluke-1730-Hanger C120B SW90W BB120-II (set of two) C120B Fluke-1730-Hanger SW90W SP120B 66 123B/124B/125B Users Manual Item (see Figure 1) not...
User Manual
Page 93
... isolated USB to PC/laptop Transfer screen dumps (bitmaps), settings and data using OC4USB optically isolated USB adapter/cable, (optional), using FlukeView® ScopeMeter® software for safety reasons.
... isolated USB to PC/laptop Transfer screen dumps (bitmaps), settings and data using OC4USB optically isolated USB adapter/cable, (optional), using FlukeView® ScopeMeter® software for safety reasons.