Fluke 1577 Support and Manuals

Get Help and Manuals for this Fluke item

View All Support Options Below
Free Fluke 1577 manuals!
Problems with Fluke 1577?

Ask a Question

Most Recent Fluke 1577 Questions

Fluke 1577 Insulation Meter Lcd Display Problem
When i turn on my tester the display only are four dashline.
(Posted by Nard735 1 year ago)

Popular Fluke 1577 Manual Pages

FE 1587-1577 Users Manual - Page 1

PN 2401027 April 2005 Rev.1, 1/06 © 2005-2006 Fluke Corporation. All rights reserved. Printed in USA All product names are trademarks of their respective companies. ® 1587/1577 Insulation Multimeters Users Manual
FE 1587-1577 Users Manual - Page 11

...Insulation Multimeters Introduction The Fluke Models 1587,1587T, and 1577 are designed to protect against transients in Fixed equipment installations at : register.fluke.com 1 Although this manual describes the operation of all models, all illustrations and examples assume use of danger from anywhere in Singapore +1-425-446-5500 from transient impulses. The Meter measures or tests...
FE 1587-1577 Users Manual - Page 17

...hold to return to display maximum, minimum, and average values. Functions as a shift key. Insulation Multimeters Buttons Button Description f (1587 and 1587T only) Activate frequency measurement. Press again to Manual Ranging mode. The blue button. Table 3. The test lock acts to hold to start retaining maximum, minimum, and average values. G Press to release...
FE 1587-1577 Users Manual - Page 20

... the 1587. 500 (default) and 1000 V ranges available on the 1577. 50 (default) and 100 V on the 1587T. The t button is disabled until the battery is replaced. The message appears briefly and a single beep will not operate at all until the battery is replaced. Service Meter if this is present. 10 Table 5. Test lead alert. Model detect error. Display...
FE 1587-1577 Users Manual - Page 25

... improve measurement performance on Insulation Multimeters Understanding AC Zero Input Behavior of hazardous voltage. The Meter continues measuring in the ...Filter (Model 1587 and 1587T) The 1587 is not available with an ac low-pass filter. Refer to Manual mode....do not affect the Meter's ac measurement accuracy over the specified measurement ranges. When the test leads are normal....
FE 1587-1577 Users Manual - Page 34

1587/1577 Users Manual Testing Insulation Insulation tests should only be performed until the batteries are replaced. 3. To measure insulation resistance set up the Meter as shown in this manual. Insulation tests cannot be performed on the primary display until t is present. In this position. When resistance is higher than 30 V ac or dc is released. See Testing the Fuse later in...
FE 1587-1577 Users Manual - Page 35

... switch to end this function Figure 13. Testing Insulation bav13f.eps 25 LO HOLD MIN MAX Insulation Multimeters Making Basic Measurements Measuring Frequency (Model 1587 and 1587T) The Meter measures the frequency of a voltage or current...signal source. 2. Press the f button. 5. To measure frequency, set up the Meter as shown in Figure 14 and follow the steps below. 1. Connect the...
FE 1587-1577 Users Manual - Page 39

... per MIL-PRF-28800F, Class 2 instrument Shock 1 meter drop per IEC 61010-1 2nd Edition (1 meter drop test, six sides, oak floor) Electromagnetic Compatibility In an RF field of 5 seconds on and 25 seconds off. TUV per standard CSA/CAN C22.2 No. 61010.1-04; Insulation Multimeters Specifications Specifications General Specifications Maximum Voltage Applied to any Terminal.........1000 V ac...
FE 1587-1577 Users Manual - Page 41

...Insulation Multimeters Electrical Specifications 1587...% + 3) - (6 % - 3) + (2 % + 3) - (6 % - 3) + (2 % + 3) - (6 % - 3) + (2 % + 3) - (6 % - 3) 1577 Accuracy Range 600.0 mV 6.000 V 60.00 V 600.0 V 1000 V Resolution 0.1 mV 0.001 V 0.01 V 0.1 V 1 V 50 Hz to 60 Hz ± (% of...sine wave input. Conversions are ac-coupled and calibrated to crest factor Input signal crest factor can be up to 3...
Fluke 1577 and 1587 Insulation Multimeter Datasheet - Page 1

1587/1577 Insulation Multimeters Technical Data Two powerful tools in a single compact, handheld unit, which provides maximum versatility for both troubleshooting and preventative maintenance. Whether you work • Rugged, utility hard case allows you to bring everything you have come to expect from Fluke, the 1587 and 1577 are ideally suited to help you with your hands for other tools ...
Fluke 1577 and 1587 Insulation Multimeter Datasheet - Page 2

... @ dc, 50 Hz or 60 Hz (1 k unbalance) Overload protection: 1000 V rms or dc Accuracy 15771 0.2 % + 2 0.2 % + 2 0.2 % + 2 0.2 % + 2 DC millivolts measurement Range 600.0 mV dc Resolution 0.1 mV Accuracy 1587 0.1 % + 1 Accuracy 1577 0.2 % + 1 2 Fluke Corporation 1587/1577 Insulation Multimeters
Fluke 1577 and 1587 Insulation Multimeter Datasheet - Page 3

... 1587/1577 Insulation Multimeters Fluke ...test voltage: < 8.0 V dc Short circuit current: < 1.1 mA Diode test (1587 Only) Diode test indication: Display voltage drop: 0.6 V at 1.0 mA nominal test current Accuracy: + (2 % + 1) Continuity test Continuity indication: Continuous audible tone for test resistance below 25 Ω and off above 100 Ω. Conversions are ac-coupled and calibrated...
Fluke 1577 and 1587 Insulation Multimeter Datasheet - Page 4

... 0.1 °C 0.1 °F Accuracy1 1 % + 10 counts 1 % + 18 counts 1Accuracies apply following 90 minutes settling time after a change in the ambient temperature of test Maximum capacitive load: Operable with up to 100 kHz with full scale input. Noise at low frequencies and amplitudes may affect accuracy. 2Usable to 1 µF load 4 Fluke Corporation 1587/1577 Insulation Multimeters
Fluke 1577 and 1587 Insulation Multimeter Datasheet - Page 5

...-1, IEC61557-2 1587/1577 Insulation Multimeters Fluke Corporation 5 TUV per standard CSA/CAN C22.2 No. 61010.1-04; These are standard tests of 1000 ...meter drop per IEC 61010-1 2nd Edition (1 meter drop test, six sides, oak floor) Electromagnetic compatibility: In an RF field of range except for measurement CAT III 1000 V and CAT IV 600 V Certifications: CSA per standard EN 61010 Part...
Fluke 1577 and 1587 Insulation Multimeter Datasheet - Page 6

..., test leads, alligator clips, K-type thermocouple (1587 only), hard case, user documentation Optional accessories 1577 TPAK Magnetic Tool Hanger i400s Clamp with Adapter C25 Soft Case 1587 • • TPAK i400s C25 For additional accessories for these products, see the Top 10 Accessories for Insulation Multimeters at www.MyFlukeStore.com or ask for Fluke literature code 2427793...

Fluke 1577 Reviews

Do you have an experience with the Fluke 1577 that you would like to share?
Earn 750 points for your review!
We have not received any reviews for Fluke yet.

Popular Fluke 1577 Search Terms

The following terms are frequently used to search for Fluke 1577 support:

Ask a New Question
Use the box below to post a new question about Fluke 1577.
Manuals / Documents
Download any of our Fluke 1577 manuals for free!

We have the following 2 documents available for the Fluke 1577:
  • FE 1587-1577 Users Manual
  • Fluke 1577 and 1587 Insulation Multimeter Datasheet
Related Items
View other Fluke Electronics Accessories:

Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Fluke Manuals

Find free Fluke 1577 manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Fluke Reviews

View thousands of Fluke 1577 user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Fluke customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Fluke customer service rankings, employee comments and much more from our sister site.

Fluke Recalls

Find comprehensive Fluke recall information updated hourly on RecallOwl.com.