User Manual
Page 1
All rights reserved. 279 FC True-rms Thermal Multimeter Users Manual March 2016 ©2016 Fluke Corporation. All product names are trademarks of their respective companies.
All rights reserved. 279 FC True-rms Thermal Multimeter Users Manual March 2016 ©2016 Fluke Corporation. All product names are trademarks of their respective companies.
User Manual
Page 11
... information. 1 Introduction The 279 FC True-rms Thermal Multimeter (the Multimeter or Product) is a system that wirelessly connects your Multimeter with your team. The Multimeter measures or tests: • AC voltage • AC current with an integrated thermal imaging camera. You can save these measurements and images to awkward-sized conductors and wires The Multimeter supports the Fluke Connect™ Wireless System...
... information. 1 Introduction The 279 FC True-rms Thermal Multimeter (the Multimeter or Product) is a system that wirelessly connects your Multimeter with your team. The Multimeter measures or tests: • AC voltage • AC current with an integrated thermal imaging camera. You can save these measurements and images to awkward-sized conductors and wires The Multimeter supports the Fluke Connect™ Wireless System...
User Manual
Page 22
... Information Use the Device Information menu to delete all images: 1. Push . When 100 images are in memory, the Multimeter will prompt you to overwrite the first (oldest) image before you can go to the Setup Menu to find details about the.... 2. Or, you can continue to save up to exit the submenu with no changes. 12 Calibration For information about your Multimeter, see the 279 FC True-rms Thermal Multimeter Calibration Manual. 279 FC Users Manual Image Memory Management You can save . Push (Select) to highlight Image Memory. 3. Push ...
... Information Use the Device Information menu to delete all images: 1. Push . When 100 images are in memory, the Multimeter will prompt you to overwrite the first (oldest) image before you can go to the Setup Menu to find details about the.... 2. Or, you can continue to save up to exit the submenu with no changes. 12 Calibration For information about your Multimeter, see the 279 FC True-rms Thermal Multimeter Calibration Manual. 279 FC Users Manual Image Memory Management You can save . Push (Select) to highlight Image Memory. 3. Push ...
User Manual
Page 45
... Black Alligator Clip, Red 279 FC Quick Reference Guide 279 FC Safety Information 9-inch Hanger Strap Hanging Clip USB A to USB mini-B Cable Soft Carry Case 7.4 V 3000 mAh Rechargeable Lithium-Ion Battery 15 V dc Charger 10 in . iFlex Current Probe Fluke Part or Model Number 4693466 ...TL175 AC175 4694103 4717467 TPAK80-4-8001 TPAK80-2003 1671807 3087338 BP500 BC500 i2500-10 i2500-18 35 True-rms Thermal Multimeter Parts and Accessories Item Table 6. iFlex Current Probe 18 in .
... Black Alligator Clip, Red 279 FC Quick Reference Guide 279 FC Safety Information 9-inch Hanger Strap Hanging Clip USB A to USB mini-B Cable Soft Carry Case 7.4 V 3000 mAh Rechargeable Lithium-Ion Battery 15 V dc Charger 10 in . iFlex Current Probe Fluke Part or Model Number 4693466 ...TL175 AC175 4694103 4717467 TPAK80-4-8001 TPAK80-2003 1671807 3087338 BP500 BC500 i2500-10 i2500-18 35 True-rms Thermal Multimeter Parts and Accessories Item Table 6. iFlex Current Probe 18 in .
Calibration Guide
Page 1
Specifications are trademarks of their respective companies. All product names are subject to change without notice. 279 FC True-rms Thermal Multimeter Calibration Manual July 2016 ©2016 Fluke Corporation. All rights reserved.
Specifications are trademarks of their respective companies. All product names are subject to change without notice. 279 FC True-rms Thermal Multimeter Calibration Manual July 2016 ©2016 Fluke Corporation. All rights reserved.
Calibration Guide
Page 5
..., or download the latest manual supplement, visit http://us.fluke.com/usen/support/manuals. 1 Introduction XW Warning To prevent possible electrical shock, fire, or personal injury, read all safety information before you use the Product. See the 279 FC Users Manual for the 279 FC True-rms Thermal Multimeter (the Multimeter or Product). To register your Product, visit http://register...
..., or download the latest manual supplement, visit http://us.fluke.com/usen/support/manuals. 1 Introduction XW Warning To prevent possible electrical shock, fire, or personal injury, read all safety information before you use the Product. See the 279 FC Users Manual for the 279 FC True-rms Thermal Multimeter (the Multimeter or Product). To register your Product, visit http://register...
Calibration Guide
Page 13
...Point) WCaution For IR calibration with the Fluke 4180 IR Precision Calibrator, it is a slight amount) is necessary. Connect a 6 mm (0.25 in Table 3, calibration adjustment or repair is on page 15. 279 FC iFlex 5522A Figure 2. If the display indication ... or moisture on the Multimeter display with a purge inlet. If any ice or moisture. Fluke recommends that environment. To use the purge: 1. See Calibration Adjustment on the target, the display temperature accuracy is critical to drift. True-rms Thermal Multimeter Performance Tests Current Tests For...
...Point) WCaution For IR calibration with the Fluke 4180 IR Precision Calibrator, it is a slight amount) is necessary. Connect a 6 mm (0.25 in Table 3, calibration adjustment or repair is on page 15. 279 FC iFlex 5522A Figure 2. If the display indication ... or moisture on the Multimeter display with a purge inlet. If any ice or moisture. Fluke recommends that environment. To use the purge: 1. See Calibration Adjustment on the target, the display temperature accuracy is critical to drift. True-rms Thermal Multimeter Performance Tests Current Tests For...
Calibration Guide
Page 15
Fluke 4180/4181 Fluke 279 FC iFlex True-rms Thermal Multimeter Performance Tests 20 in 51 cm Figure 3. IR Camera Performance Test Configuration 11
Fluke 4180/4181 Fluke 279 FC iFlex True-rms Thermal Multimeter Performance Tests 20 in 51 cm Figure 3. IR Camera Performance Test Configuration 11