Fluke 87V Support and Manuals

Get Help and Manuals for this Fluke item

View All Support Options Below
Free Fluke 87V manuals!
Problems with Fluke 87V?

Ask a Question

Most Recent Fluke 87V Questions

Err Pr
(Posted by jerryvcb 6 months ago)
F 8 Error Cord
(Posted by pradeep822401180 8 months ago)
Fluke 87v Error Code
When i turn on my fluke 87v, the lcd display LEAD error and also beeping
(Posted by edgarcabrera723 2 years ago)
Error F8 On My Fluke 87v Pls Help Me To Solve It
(Posted by Prosperlavoe12 2 years ago)

Fluke 87V Videos

EEVblog #112 - GSM vs The Fluke 87V Multimeter
Duration: 14:49
Total Views: 72,903
Fluke 87v Response Time
Duration: 1:52
Total Views: 41
How to Measure Frequency And Duty Cycle With A Fluke 87V Multimeter
Duration: 3:22
Total Views: 3,780
How To Configure A Fluke 87V Multimeter To Use AC And AC DC Current Clamps
Duration: 1:39
Total Views: 2,036

Popular Fluke 87V Manual Pages

FE 83V & 87V Users Manual - Page 21

... a test lead is plugged into a current terminal. To disable automatic power-off . Table 4 includes the power-up option. To measure ac or dc voltage, refer to mV. Power-Up Options Holding a button down while turning the Meter on activates a power-up options. Measuring AC and DC Voltage Model 87 features true rms readings, which...
FE 83V & 87V Users Manual - Page 22

... manually select a dc voltage range equal to or higher than the ac range. This procedure improves the accuracy of an ac voltage, measure the ac voltage first. For better accuracy when measuring the dc offset of the dc measurement by ensuring that the input protection circuits are not activated. 14 87 V TRUE RMS MULTIMETER AC...
FE 83V & 87V Users Manual - Page 25

... MIN MAX ˚C/˚F RANGE REL mV V AutoHOLD Hz % mA A LO V A OFF A mA A COM V 10A MAX FUSED 400mA FUSED Activates continuity beeper ON (closed) 87 V TRUE RMS MULTIMETER MIN MAX Peak MIN MAX 4½ DIGITS 1 Second ˚C/˚F RANGE REL mV V AutoHOLD Hz % mA A LO V A OFF A mA A COM V 10A MAX FUSED 400mA FUSED...
FE 83V & 87V Users Manual - Page 27

In-Circuit Resistance Measurements 87 V TRUE RMS MULTIMETER Circuit Power OFF MIN MAX Peak MIN MAX 4½ DIGITS 1 Second ˚C/˚F RANGE REL mV V AutoHOLD Hz % mA A LO V A OFF A mA A COM V 10A MAX FUSED 400mA FUSED Making Measurements Isolating a Potentiometer 1 3 2 Disconnect 1 2 3 Isolating a Resistor Figure 5. Measuring Resistance Disconnect aom6f.eps 19
FE 83V & 87V Users Manual - Page 29

... and leads. Measuring Capacitance aom10f.eps 21 Note If too much electrical charge is discharged. The Meter's capacitance ranges are 10.00 nF, 100.0 nF, 1.000 µF, 10.00 µF, 100.0 µF, and 9999 µF. To measure capacitance, set up the Meter as shown in Figure 6. Making Measurements Select Capacitance 87 V TRUE RMS MULTIMETER MIN...
FE 83V & 87V Users Manual - Page 31

...A A mA A COM V 10A MAX FUSED 400mA FUSED Typical Reading Forward Bias + Single Beep 87 V TRUE RMS MULTIMETER MIN MAX Peak MIN MAX ˚C/˚F RANGE REL AutoHOLD Hz % mV V LO V OFF mA A... A A mA A COM V 10A MAX FUSED 400mA FUSED Making Measurements Reverse Bias + 87 V TRUE RMS MULTIMETER MIN MAX Peak MIN MAX ˚C/˚F RANGE REL AutoHOLD Hz % mV V LO V OFF mA ...
FE 83V & 87V Users Manual - Page 33

OFF to circuit 5 Current through one component Figure 8. ON for measurement. Measuring Current 5 aom7f.eps 25 Making Measurements Total current to disconnect meter. 1 87 V TRUE RMS MULTIMETER MIN MAX Peak MIN MAX 4½ DIGITS 1 Second ˚C/˚F RANGE REL mV V AutoHOLD Hz % mA A LO V A OFF A mA A COM V 10A MAX FUSED 400mA FUSED 4 ...
FE 83V & 87V Users Manual - Page 44

... battery and the battery door. Testing the Current Fuses Replacing the Battery Replace the battery with a 9 V battery (NEDA A1604, 6F22, or 006P). 80 Series V Users Manual Good F2 fuse: 00.0 Ω to 00.5 Ω Replace fuse: OL Touch top half of input contacts 87 V TRUE RMS MULTIMETER MIN MAX Peak MIN MAX 4½ DIGITS 1 Second ˚C/˚F RANGE REL...
FE 83V & 87V Users Manual - Page 52

80 Series V Users Manual Detailed Specifications For all detailed specifications: Accuracy is given as ±([% of reading] + [number of least significant digits]) at 18° C to 28° C, with leads shorted, will cause only a 2-digit change for a period of range, add 12 counts. 2. When the input leads are accoupled and valid from -1% at 440 Hz when filter is...
FE 83V & 87V Users Manual - Page 56

... Below a reading of range. AC conversions for Model 83 is a true rms responding meter. Using REL to offset this reading may produce a much larger constant error in the ac functions, the Meter may display a residual reading between 1 and 30 counts. 80 Series V Users Manual Table 14. AC conversion for Model 87 are shorted together in later measurements 4.
Getting Started Guide - Page 5

... Pass Filter ...11 iii Inputs...4 3. DC Voltage, Resistance, and Conductance Function Specifications 17 10. MIN MAX Recording Specifications 21 List of the Terminals 21 16. List of Tables Table Title Page 1. Model 87 AC Voltage Function Specifications 15 8. Model 83 AC Voltage Function Specifications 16 9. Frequency Counter Specifications 19 14. Display Features...
Getting Started Guide - Page 16

... terminal being tested. WTest lead alert. Display Features (cont.) Feature Indication A, μA, mA Amperes (amps), Microamp, Milliamp V, mV Volts, Millivolts μF, nF Microfarad, Nanofarad nS Nanosiemens % Percent. For more information, See "Bar Graph" in high resolution (Hi Res) mode. Have Meter serviced. 80 Series V Getting Started Manual Number M N O P Q Table 5. The...
Getting Started Guide - Page 21

... 30 counts. When the input leads are ac-coupled and valid from -1% at 200 Hz to 3. For non-sinusoidal wave forms add -(2 % Rdg + 2 % full scale) typical, for a period of range. For Model 87 in the ac functions, the Meter may produce a much larger constant error in use. 15 Model 87 is a true rms responding meter. AC conversions...
Getting Started Guide - Page 22

80 Series V Getting Started Manual Table 8. Model 83 AC Voltage Function Specifications Function Range Resolution Accuracy K1 600.0 mV 0.1 mV 6.000 V 0.001 V 60.00 V 0.01 V 600.0 V 0.1 V 1000 V 1 V 1. Below a reading of 200 counts, add 10 counts. 2. Frequency range: 1 ...
Getting Started Guide - Page 24

... for readings over 3 % of a sine wave input. 2. When the input leads are ac coupled, true rms responding, and valid from 3 % to 100 % of range, except 400 mA range (5 % to 100 % of range) and 10 A range (15 % to the rms value of range. Current Function Specifications Resolution 0.01 mA 0.1 mA 0.001 A 0.01 A Model 831 ± (1.2 % + 2)5 ± (1.2 % + 2)5 ± (1.2 % + 2)5 ±...

Fluke 87V Reviews

Do you have an experience with the Fluke 87V that you would like to share?
Earn 750 points for your review!
We have not received any reviews for Fluke yet.

Popular Fluke 87V Search Terms

The following terms are frequently used to search for Fluke 87V support:

Ask a New Question
Use the box below to post a new question about Fluke 87V.
Manuals / Documents
Download any of our Fluke 87V manuals for free!

We have the following 2 documents available for the Fluke 87V:
  • FE 83V & 87V Users Manual
  • Getting Started Guide
Related Items

Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Fluke Manuals

Find free Fluke 87V manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Fluke Reviews

View thousands of Fluke 87V user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Fluke customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Fluke customer service rankings, employee comments and much more from our sister site.

Fluke Recalls

Find comprehensive Fluke recall information updated hourly on RecallOwl.com.