Get support for Fluke 87V

Fluke 87V Support Question

Fluke 87V Support Question

Find answers below for this question about Fluke 87V.
Need a Fluke 87V manual? We have 2 online manuals for this item!
Question posted by pradeep822401180 on August 5th, 2023

F 8 Error Cord

The person who posted this question about this Fluke product did not include a detailed explanation. Please use the "Request More Information" button to the right if more details would help you to answer this question.

Current Answers

Answer #1: Posted by SonuKumar on August 5th, 2023 10:36 PM
This answer was accepted by the poster of the original question.
SonuKumar

Member since:
May 9th, 2021

Points: 16,618,310
1,100
points
The F8 error code on a Fluke 87V multimeter indicates a problem with the test leads or the cord. The most common cause of this error is a loose or damaged connection between the test leads and the multimeter. To fix this error, you can try the following:

Check the connections between the test leads and the multimeter. Make sure that they are securely plugged in and that there are no loose wires.

Try using a different set of test leads. If you have a spare set, try using them to see if the error goes away.

If you have a multimeter with a detachable cord, try using a different cord. This could help to isolate the problem to the cord itself.

If you have tried all of these steps and the F8 error code is still displayed, you may need to contact Fluke for further assistance.

Here are some additional things to keep in mind:

The F8 error code can also be caused by a problem with the multimeter itself. However, this is less common than a problem with the test leads or the cord.

If you are using the Fluke 87V in a noisy environment, such as near a power transformer, you may also get the F8 error code. This is because the multimeter is unable to accurately measure the voltage in a noisy environment.

If you are still having trouble with the Fluke 87V, you can contact Fluke customer support for assistance. They will be able to help you troubleshoot the problem and determine the best course of action.


Please respond to my effort to provide you with the best possible solution by using the "Acceptable Solution" and/or the "Helpful" buttons when the answer has proven to be helpful.

Regards,
Sonu
Your search handyman for all e-support needs!!

Related Fluke 87V Manual Pages

FE 83V & 87V Users Manual - Page 5

Rotary Switch Positions...7 4. Functions and Trigger Levels for Frequency Measurements 28 7. Accessories ...42 10. MIN MAX Recording Specifications 52 iii Model 87 AC Voltage Function Specifications 44 11. Current Function Specifications 48 15. Frequency Counter Specifications 49 ...
FE 83V & 87V Users Manual - Page 20

... data. Have Meter serviced. Calibrate Meter. WTest lead alert. In normal operation 0 (zero) is on the capacitor being used. For more information, see "Bar Graph". Error Messages Replace the battery immediately. HiRes=19,999 The Meter is present on the left of the graph indicates the polarity of the input. In...
FE 83V & 87V Users Manual - Page 22

... MAX FUSED 400mA FUSED + aom2f.eps Figure 2. This procedure improves the accuracy of an ac voltage, measure the ac voltage first. In most cases, the error is negligible (0.1% or less) if the circuit impedance is 10 kΩ (10,000 Ω) or less. This loading effect can cause measurement...
FE 83V & 87V Users Manual - Page 26

To test the leads, touch the probe tips together and read the resistance of error to Table 18. 18 Because this is suspected, press C to apply a lower current in the next higher range. The following are 600.0 Ω, 6.000 kΩ, ...
FE 83V & 87V Users Manual - Page 37

... MAX; then press Hz a second time. As with the Making Measurements frequency function, you can be up the Meter to measure frequency; Systems such as electronic fuel injection systems and switching power supplies are controlled by measuring duty cycle. To measure duty cycle, set up to the AVG (average) display. +Slope...
FE 83V & 87V Users Manual - Page 45

...-end of the top case from inside of the case. 5. Review this manual to "Contacting Fluke". 37 To order parts and accessories, refer to verify proper use of its bracket. 6. Remove the three Phillips-head screws from the terminals. 2. Remove the fuse by... by turning the screws one end loose, then sliding the fuse out of the Meter. Replacement parts and accessories are in Table 8.
FE 83V & 87V Users Manual - Page 50

80 Series V Users Manual Table 9. Accessories Item Description AC72 Alligator Clips for use with TL75 test lead set AC220 Safety Grip, Wide-Jaw Alligator Clips TPAK ToolPak Magnetic...TL224 Test Lead Set, Heat-Resistant Silicone TP1 Test Probes, Flat Blade, Slim Reach TP4 Test Probes, 4 mm diameter, Slim Reach Fluke accessories are available from an authorized Fluke distributor. 42
FE 83V & 87V Users Manual - Page 52

... in use. 44 For Model 87 in later measurements. 3. AC conversions are shorted together in the ac functions, the Meter may produce a much larger constant error in the 4 ½-digit mode, multiply the number of range, add 12 counts. 2. For non-sinusoidal wave forms add -(2 % Rdg + 2 % full scale) typical, for readings...
FE 83V & 87V Users Manual - Page 55

... °C 0.1 °C 1 % + 10 -328 °F to ± 1 °C. Accuracy specification assumes ambient temperature stable to +1994 °F 0.1 °F 1 % + 18 1. Specifications Table 13. Does not include error of ± 5 °C, rated accuracy applies after 1 hour. 47
FE 83V & 87V Users Manual - Page 56

AC conversions for Model 87 are shorted together in the ac functions, the Meter may produce a much larger constant error in later measurements 4. Model 87 is ac coupled and calibrated to the rms value of a sine wave input. 2. Current Function Specifications Function mA \ (45 Hz ...
Getting Started Guide - Page 21

... For all detailed specifications: Accuracy is in use. 15 AC conversions are shorted together in the ac functions, the Meter may produce a much larger constant error in the 4 ½-digit mode, multiply the number of range, add 12 counts. [2] The Meter is true rms responding.
Getting Started Guide - Page 23

... nS range. Add 0.5 % of ± 5 °C, rated accuracy applies after 1 hour. 17 When using the REL Δ function to compensate for offsets. 2. Does not include error of the thermocouple probe. 2. Multimeters Specifications Function Table 9.
Getting Started Guide - Page 24

... mA for 18 hrs maximum. 18 AC conversion for Model 87 are shorted together in the ac functions, the Meter may produce a much larger constant error in later measurements 4. Current Function Specifications Resolution 0.01 mA 0.1 mA 0.001 A 0.01 A Model 831 ± (1.2 % + 2)5 ± (1.2 % + 2)5 ± (1.2 % + 2)5 ± (1.2 % + 2)5 Accuracy Model 872, 3 ± (1.0 % + 2) ±...

Similar Questions

Fluke 87v Error Code
When i turn on my fluke 87v, the lcd display LEAD error and also beeping
(Posted by edgarcabrera723 2 years ago)
Meaning Of Error Message [ 511]
hi, I'm discovering the fluke 8845A multimeter, i try to connect the usb/serial cable provided with ...
(Posted by khaoula 6 years ago)
My Fluke 87v Cal Error. What Can I Do?
when I turn on the tester a cal err messaje .what can I do?
(Posted by euriosoler123 7 years ago)
F8 Error Help
My Fluke 87V has error name F8 Error. I cant repair, i need your help now. Thanks.
(Posted by quycali 8 years ago)
Ask a New Question
Use the box below to post a new question about this Fluke product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Fluke Manuals

Find free Fluke 87V manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Fluke Reviews

View thousands of Fluke user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Fluke customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Fluke customer service rankings, employee comments and much more from our sister site.

Fluke Recalls

Find comprehensive Fluke recall information updated hourly on RecallOwl.com.