error en display rf
(Posted by Israelmxli 1 month ago)
I Am Getting An Rf Error, What Do I Do?
(Posted by bensalazar7164 1 year ago)
Fluke Error Rf
No display error r
(Posted by wwwadmontes13 2 years ago)
Fluke 381 Red Triangle
My fluke 381 stopped working it has new batteries but only the red triangle lights up
(Posted by tacevedo1018 3 years ago)
I Get A 'do9' Message Flash When I Turn Off The Meter.
The message flashes until it dies. It is a detachable face meter so I switched the faces and the new...
(Posted by RAErickson 3 years ago)

Fluke 381 Videos

Multimetro a pinza 381
Duration: :31
Total Views: 13
Pince multimètre à affichage distant TRMS Fluke 381 - FLUKE
Duration: :32
Total Views: 18
Fluke 381 und i-Flex
Duration: :34
Total Views: 761
Fluke 381 Remote Display Clamp Meter Video Short
Duration: :29
Total Views: 455

Popular Fluke 381 Manual Pages

Fluke 381 Clamp Meter Product Datasheet - Page 2

...turns off when the display is connected to the meter • Large, easy to read, backlight display automatically sets the correct measurement range so you do not need to change switch positions while taking a measurement • Three-year warranty • Soft carrying case Ordering information 381 Remote Display True-rms Clamp Meter with iFlex™ Specifications Fluke 381 AC current via jaw...
Fluke 381 Users Manual - Page 1

Printed in China. All rights reserved. All product names are subject to change without notice. Specifications are trademarks of their respective companies. 381 Remote Display True-rms Clamp Meter Users Manual PN 3538357 July 2010 © 2010 Fluke Corporation.
Fluke 381 Users Manual - Page 5

... environments, or very tight spaces. How to 2500 A ac) and larger cables that has a remote-display module and detachable iFlex (Flexible Current Probe). The Fluke 381 is a handheld, battery-operated Clamp Meter (the Meter) that traditional jawed meters cannot measure. This lets the display be removed from the measurement source. The Flexible Current Probe makes it possible to measure...
Fluke 381 Users Manual - Page 6

...Meter only as specified in this manual are inserted into the input jacks. • Make sure the battery door is opened. 2 381 Users Manual • Singapore: +65-738-5655 • Anywhere in the world: +1-425-446-5500 Or, visit Fluke...visit http://register.fluke.com. To see, print, or download the latest manual supplement, visit http://us.fluke.com/usen/support/manuals. A Caution identifies conditions ...
Fluke 381 Users Manual - Page 9

... B Battery. T Double insulated ~ Do not dispose of Danger. Remote Display True-rms Clamp Meter Safety Information Table 1. Low battery when shown. Important information. X Hazardous voltage P Conforms to Fluke's website for recycling information. 5 Go to European Union directives. See Manual. ) Conforms to relevant North American Safety Standards. Symbols Symbol...
Fluke 381 Users Manual - Page 10

... any combination of any individual component. 6 Do not apply to relevant Australian standards. - 381 Users Manual Symbol Meaning Symbol Meaning CAT III IEC Measurement Category III CAT III equipment has protection against transients from HAZARDOUS LIVE conductors is the LOWEST rating of test probe, test probe accessory, current clamp accessory, and the Meter is permitted.
Fluke 381 Users Manual - Page 11

... installation. This device can be determined by the general public. Examples of the device. If this equipment does cause harmful interference to operate the equipment. Remote Display True-rms Clamp Meter Radio Frequency Data Radio Frequency Data Note Changes or modifications to the wireless 2.4 GHz radio not expressly approved by Fluke Corporation could void the user's authority...
Fluke 381 Users Manual - Page 12

... a different location than the Meter base. Usually, the radio signal is off when the display module is docked to correct the interference by one display module can be synchronized with a Meter base when it is docked on the Meter base and turned on. See Figure 2 and Table 2. 381 Users Manual off and on, the user is encouraged to try...
Fluke 381 Users Manual - Page 14

... avoid electrical shock, do not apply or remove from live hazardous conductors. 381 Users Manual Hazardous Voltage Indicator When the Meter senses a voltage ±30 V or a voltage overload (OL), Y is shown on the display and the red high-voltage LED () on the Meter base illuminates to -reach areas and works well with large conductors. For...
Fluke 381 Users Manual - Page 16

... of such an event. Low Battery Indicators The Meter uses two low battery symbols: Band Q. Current spikes from motor drives are not affected by low batteries in the Meter base should be changed . When B appears, the batteries in the display. 12 Low batteries on . 381 Users Manual Inrush Inrush Current is surge current that occurs when...
Fluke 381 Users Manual - Page 20

Push Z to shift to frequency. 381 Users Manual Switch Position OFF K L K A C D Table 3. Rotary Function Switch Meter is powered down AC voltage DC voltage Function Resistance and continuity AC current. Push Z to shift to frequency. 16 DC current AC current and frequency measurement using the Flexible Current Probe.
Fluke 381 Users Manual - Page 22

... Item Inrush is active H Hold is active I C Volts J D Amps K E Ohms, DC, AC, Hz L F Main display M G Remote display low-battery symbol N O Description Meter base low-battery symbol Measurement is taken at the Jaw. Min Max mode is present. RF signal is being sent to remote display. 381 Users Manual Item A B Table 4. Min, Max, or Avg reading is being shown.
Fluke 381 Users Manual - Page 25

Current Measurement with Jaw ghn04.eps 21 CAT 1000 V CAT 600 V 1000 A Remote Display True-rms Clamp Meter Measurements 6C01A0C0TV0A0TV 381 TRRMEMS OCTLEAMDPISPMLEATYER iFlex 1000 A Figure 4.
Fluke 381 Users Manual - Page 35

Meter Base 1 3766406 Fluke 381 Remote Display 1 3766445 Soft Case 1 3752973 User Manual 1 3538357 31 Display Module 1 3625529 Battery Door - Fluke Part Number Battery, AAA 1.5 V 5 2838018 Battery Door - Remote Display True-rms Clamp Meter User-Replaceable Parts User-Replaceable Parts Table 5. User-Replaceable Parts Description Qty.
Fluke 381 Users Manual - Page 39

Remote Display True-rms Clamp Meter Specifications Distance from Optimum A i2500-10 Flex 0.5 in (12.7 mm) i2500-18 Flex 1.4 in (35.6 mm) Error ± 0.5 % B 0.8 in (20.3 mm) 2.0 in (50.8 mm) ± 1.0 % C 1.4 in (35.6 mm) 2.5 in (63.5 mm) ± 2.0 % Measurement uncertainty assumes centralized primary conductor at optimum position, no ...

Fluke 381 Reviews

Do you have an experience with the Fluke 381 that you would like to share?
Earn 750 points for your review!
We have not received any reviews for Fluke yet.

Popular Fluke 381 Search Terms

The following terms are frequently used to search for Fluke 381 support:

Ask a New Question
Use the box below to post a new question about Fluke 381.
Manuals / Documents
Download any of our Fluke 381 manuals for free!

We have the following 2 documents available for the Fluke 381:
  • Fluke 381 Users Manual
  • Fluke 381 Clamp Meter Product Datasheet
Related Items
View other Fluke Electronics Accessories:

Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Fluke Manuals

Find free Fluke 381 manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Fluke Reviews

View thousands of Fluke 381 user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Fluke customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Fluke customer service rankings, employee comments and much more from our sister site.

Fluke Recalls

Find comprehensive Fluke recall information updated hourly on RecallOwl.com.