FE 83V & 87V Users Manual
Page 24
... Push C to 1994.0 °F. W Caution To avoid possible damage to the Meter or other equipment, remember that range, use a higher rated thermocouple. To measure temperature, do the following: 1. To test for continuity, set up the Meter as a circuit is complete. The beeper allows you ... intermittent opens and shorts lasting as little as 1ms. A brief short causes the Meter to watch the display. Connect a type-K thermocouple to the equipment under test, disconnect circuit power and discharge all high-voltage capacitors before testing for Continuity WCaution To avoid possible damage ...
... Push C to 1994.0 °F. W Caution To avoid possible damage to the Meter or other equipment, remember that range, use a higher rated thermocouple. To measure temperature, do the following: 1. To test for continuity, set up the Meter as a circuit is complete. The beeper allows you ... intermittent opens and shorts lasting as little as 1ms. A brief short causes the Meter to watch the display. Connect a type-K thermocouple to the equipment under test, disconnect circuit power and discharge all high-voltage capacitors before testing for Continuity WCaution To avoid possible damage ...
FE 83V & 87V Users Manual
Page 48
...MP81 MP390-391 NA U5 CR6 S2 TM1 TM2 TM3 Table 8. Replacement Parts (cont.) Description Alligator Clip, Black Alligator Clip, Red Test Lead Set Thermocouple Assembly, K-Type, Beaded, Molded Dual Banana Plug, Coiled Access Door Fastener Tiltstand LCD, 4.5 DIGIT,TN, Transflective, Bar Graph, OSPR80 Lightpipe Keypad ...80 Series V Multi-Language Getting Started Manual 80 Series V Quick Reference Card CD ROM,80 Series V User Manual Qty. 1 1 1 1 2 1 1 1 1 1 1 1 Fluke Part or Model Number 1670652 1670641 855742 1273113 948609 2074040 2065213 2074057 2105884 2101973 2101986 2101999 40
...MP81 MP390-391 NA U5 CR6 S2 TM1 TM2 TM3 Table 8. Replacement Parts (cont.) Description Alligator Clip, Black Alligator Clip, Red Test Lead Set Thermocouple Assembly, K-Type, Beaded, Molded Dual Banana Plug, Coiled Access Door Fastener Tiltstand LCD, 4.5 DIGIT,TN, Transflective, Bar Graph, OSPR80 Lightpipe Keypad ...80 Series V Multi-Language Getting Started Manual 80 Series V Quick Reference Card CD ROM,80 Series V User Manual Qty. 1 1 1 1 2 1 1 1 1 1 1 1 Fluke Part or Model Number 1670652 1670641 855742 1273113 948609 2074040 2065213 2074057 2105884 2101973 2101986 2101999 40
FE 83V & 87V Users Manual
Page 55
Does not include error of ± 5 °C, rated accuracy applies after 1 hour. 47 Specifications Table 13. For ambient temperature changes of the thermocouple probe. 2. Temperature Specifications (87 Only) Temperature Resolution Accuracy1,2 -200 °C to +1090 °C 0.1 °C 1 % + 10 -328 °F to ± 1 °C. Accuracy specification assumes ambient temperature stable to +1994 °F 0.1 °F 1 % + 18 1.
Does not include error of ± 5 °C, rated accuracy applies after 1 hour. 47 Specifications Table 13. For ambient temperature changes of the thermocouple probe. 2. Temperature Specifications (87 Only) Temperature Resolution Accuracy1,2 -200 °C to +1090 °C 0.1 °C 1 % + 10 -328 °F to ± 1 °C. Accuracy specification assumes ambient temperature stable to +1994 °F 0.1 °F 1 % + 18 1.
Getting Started Guide
Page 16
... A or mA/μA terminal and the selected rotary switch position does not correspond to the full-scale value of the input. WTest lead alert. Open thermocouple is on the 80 Series V User Manual CD.
... A or mA/μA terminal and the selected rotary switch position does not correspond to the full-scale value of the input. WTest lead alert. Open thermocouple is on the 80 Series V User Manual CD.