Page 4
Fluke TiR1/R Thermal Imagers Optimized for tough environments Engineered and tested to withstand a 2...imager lens Image capture trigger Rugged, withstands 2 m (6.5 ft) drop Easy to use ) 4 only available from Fluke. • Optimized for building envelope inspection, restoration and remediation and roofing applications. record findings by speaking into the camera... capabilities with the push of a thumb. • No need to use ... The new Fluke TiR1 and TiR Thermal Imagers are saved with the image. (TiR1 only) • Store more than 3,000 screen images (.bmp format) or 1,200 IR-...
Fluke TiR1/R Thermal Imagers Optimized for tough environments Engineered and tested to withstand a 2...imager lens Image capture trigger Rugged, withstands 2 m (6.5 ft) drop Easy to use ) 4 only available from Fluke. • Optimized for building envelope inspection, restoration and remediation and roofing applications. record findings by speaking into the camera... capabilities with the push of a thumb. • No need to use ... The new Fluke TiR1 and TiR Thermal Imagers are saved with the image. (TiR1 only) • Store more than 3,000 screen images (.bmp format) or 1,200 IR-...
Fluke TiR Thermal Imager Datasheet
Page 5
Fluke TiR1/R specifications Fluke TiR1 Fluke TiR Imaging performance Field of View (FOV ) 23° horizontal x 17° vertical Minimum focus distance Thermal lens: 15 cm (approx. 6 in), Visible (visual) light ...
Fluke TiR1/R specifications Fluke TiR1 Fluke TiR Imaging performance Field of View (FOV ) 23° horizontal x 17° vertical Minimum focus distance Thermal lens: 15 cm (approx. 6 in), Visible (visual) light ...
Fluke TiR Thermal Imager Datasheet
Page 10
... to deliver on this commitment to their needs and they have come to www. known as they paid for." Fluke 971 Temperature Humidity Meter Fluke CO-220 Carbon Monoxide Meter Fluke. Fluke is our boss. to ensure that innovation, expertise and rugged, reliable designs to the building diagnostics industry with IR...easy-to-use and safe tools, we design meet our customers' needs and are designed to improve your ability to www.fluke.com/select Ordering Information FLK-TIR1 Thermal Imager FLK-TIR Thermal Imager FLK-TIR2/FT-20 IR FlexCam BD Thermal Imager with IR-Fusion FLK-TIR3/FT-20 ...
... to deliver on this commitment to their needs and they have come to www. known as they paid for." Fluke 971 Temperature Humidity Meter Fluke CO-220 Carbon Monoxide Meter Fluke. Fluke is our boss. to ensure that innovation, expertise and rugged, reliable designs to the building diagnostics industry with IR...easy-to-use and safe tools, we design meet our customers' needs and are designed to improve your ability to www.fluke.com/select Ordering Information FLK-TIR1 Thermal Imager FLK-TIR Thermal Imager FLK-TIR2/FT-20 IR FlexCam BD Thermal Imager with IR-Fusion FLK-TIR3/FT-20 ...
FE Ti10-25-Tir-1 Users Manual
Page 1
Printed in USA All product names are trademarks of their respective companies. Ti10, Ti25, TiR and TiR1 Thermal Imagers Users Manual PN 2803044 August 2007 © 2007 Fluke Corporation, All rights reserved.
Printed in USA All product names are trademarks of their respective companies. Ti10, Ti25, TiR and TiR1 Thermal Imagers Users Manual PN 2803044 August 2007 © 2007 Fluke Corporation, All rights reserved.
FE Ti10-25-Tir-1 Users Manual
Page 3
Table of Contents Title Page Introduction 1 Contacting Fluke 1 Safety Information 2 Unpacking the Imager 3 Charging the Battery 3 Turning the Imager On and Off 3 Features and Controls 3 Using the Menu 5 Changing the Displayed Language 5 Setting ... (Ti10 and TiR Only) ........ 10 Setting IR Fusion® and PIP (Ti25 and TiR1 Only 10 Reviewing and Deleting Stored Images 10 Adding Voice Annotation to Saved Data (Ti25 and TiR1 Only 11 Listening to Voice Annotations (Ti25 and TiR1 Only 12 Changing the Temperature Units 12 Enabling/Disabling Spot Indicators (Ti25 and...
Table of Contents Title Page Introduction 1 Contacting Fluke 1 Safety Information 2 Unpacking the Imager 3 Charging the Battery 3 Turning the Imager On and Off 3 Features and Controls 3 Using the Menu 5 Changing the Displayed Language 5 Setting ... (Ti10 and TiR Only) ........ 10 Setting IR Fusion® and PIP (Ti25 and TiR1 Only 10 Reviewing and Deleting Stored Images 10 Adding Voice Annotation to Saved Data (Ti25 and TiR1 Only 11 Listening to Voice Annotations (Ti25 and TiR1 Only 12 Changing the Temperature Units 12 Enabling/Disabling Spot Indicators (Ti25 and...
FE Ti10-25-Tir-1 Users Manual
Page 7
...displayed and stored with each IR image. The thermal image temperature range starts at www.fluke.com To register your product, visit register.fluke.com 1 Introduction The Fluke Ti10, Ti25, TiR, and TiR1 Thermal Imagers (hereafter "the Imager") are displayed on the Imager LCD and can be... saved to the features mentioned above, the Ti25 and TiR1 provide voice recording for predictive maintenance,...
...displayed and stored with each IR image. The thermal image temperature range starts at www.fluke.com To register your product, visit register.fluke.com 1 Introduction The Fluke Ti10, Ti25, TiR, and TiR1 Thermal Imagers (hereafter "the Imager") are displayed on the Imager LCD and can be... saved to the features mentioned above, the Ti25 and TiR1 provide voice recording for predictive maintenance,...
FE Ti10-25-Tir-1 Users Manual
Page 8
...Imager and in this manual. See manual. O On Off Symbol f Imager in this product as specified in lower than actual temperature measurements. Go to Fluke's website for more information. W Warning To avoid a burn hazard, remember that could damage the Imager or cause permanent loss of European Union and ... Caution identifies conditions and actions that could cause bodily harm or death. Symbols Symbol Description B Battery condition. Important information. Ti10, Ti25, TiR and TiR1 Users Manual Safety Information Use the Imager only as unsorted municipal waste.
...Imager and in this manual. See manual. O On Off Symbol f Imager in this product as specified in lower than actual temperature measurements. Go to Fluke's website for more information. W Warning To avoid a burn hazard, remember that could damage the Imager or cause permanent loss of European Union and ... Caution identifies conditions and actions that could cause bodily harm or death. Symbols Symbol Description B Battery condition. Important information. Ti10, Ti25, TiR and TiR1 Users Manual Safety Information Use the Imager only as unsorted municipal waste.
FE Ti10-25-Tir-1 Users Manual
Page 20
...™ software or non-Fluke software which is supplied with the thermal imager. Press the softkey labeled File Format. 3. Images in nonproprietary software and electronic documents. Ti10, Ti25, TiR and TiR1 Users Manual To set the emissivity value directly: 1. Press the softkey labeled ε. 2. It can be changed prior to find out...
...™ software or non-Fluke software which is supplied with the thermal imager. Press the softkey labeled File Format. 3. Images in nonproprietary software and electronic documents. Ti10, Ti25, TiR and TiR1 Users Manual To set the emissivity value directly: 1. Press the softkey labeled ε. 2. It can be changed prior to find out...