Maintenance Manual
Page 124
... the idle mode. The device reports the status even if the device has not fully entered the idle mode. The APS timer is set to X 'FF'] Point of the device is enabled and the timer immediately starts the countdown. At command issuance (Shadow Block Registers setting contents) CM X '97' or X 'E3...
... the idle mode. The device reports the status even if the device has not fully entered the idle mode. The APS timer is set to X 'FF'] Point of the device is enabled and the timer immediately starts the countdown. At command issuance (Shadow Block Registers setting contents) CM X '97' or X 'E3...
Maintenance Manual
Page 126
After that, the device reports the status to be read) ST Status information DH x x x x xx CH xx CL xx SN xx SC X '00' or X 'FF' ER Error information 5-52 C141-E293 The device sets the following field value. Power save mode of the device by the contents of the device ... can confirm the power save mode • During moving to Standby mode • Standby mode • Idle mode • Active mode Sector Count field X '00' X 'FF' X 'FF' • Error reporting conditions (1) A SATA communication error occurred (ST = 51h, ER = 14h).
After that, the device reports the status to be read) ST Status information DH x x x x xx CH xx CL xx SN xx SC X '00' or X 'FF' ER Error information 5-52 C141-E293 The device sets the following field value. Power save mode of the device by the contents of the device ... can confirm the power save mode • During moving to Standby mode • Standby mode • Idle mode • Active mode Sector Count field X '00' X 'FF' X 'FF' • Error reporting conditions (1) A SATA communication error occurred (ST = 51h, ER = 14h).
Maintenance Manual
Page 138
...The host compares the attribute values with the thresholds to 7 Meaning If this bit is 1, it indicates that the drive error logging function is supported. Interface • Error logging capability Table 5.16 Drive error logging capability Bit 0 1 to identify a failure. Table 5.17 Log Directory Data Format Byte(hex) 00, ...01 02 03 04 05 to 0B 0C 0D to 11 12 13 to FF 100 101 102 to 13F 140 to Address 9Fh "...
...The host compares the attribute values with the thresholds to 7 Meaning If this bit is 1, it indicates that the drive error logging function is supported. Interface • Error logging capability Table 5.16 Drive error logging capability Bit 0 1 to identify a failure. Table 5.17 Log Directory Data Format Byte(hex) 00, ...01 02 03 04 05 to 0B 0C 0D to 11 12 13 to FF 100 101 102 to 13F 140 to Address 9Fh "...
Maintenance Manual
Page 224
... Low Exp field value 0A Cylinder High Exp field value 0B Reserved 0C Sector Count field value 0D Sector Count Exp field value 0E to FF Reserved 100 to 1FE Vendor Unique 1FF Check sum Table 5.40 Tag field information Bit 0 to 4 has an error tag number. 5-150 C141-E293 Interface...
... Low Exp field value 0A Cylinder High Exp field value 0B Reserved 0C Sector Count field value 0D Sector Count Exp field value 0E to FF Reserved 100 to 1FE Vendor Unique 1FF Check sum Table 5.40 Tag field information Bit 0 to 4 has an error tag number. 5-150 C141-E293 Interface...