Use and Care Manual
Page 3
...(s). NOTICE: Households with small children, disabled, or elderly persons may be considered when selecting the water temperature setting of water heater's thermostat. To comply with "HOT" water. READ ALL INSTRUCTIONS BEFORE USING. Children, disabled and elderly are available, see manual. DANGER HOT BURN Water temperature over 125°F can cause severe burns or death from scalds.
...(s). NOTICE: Households with small children, disabled, or elderly persons may be considered when selecting the water temperature setting of water heater's thermostat. To comply with "HOT" water. READ ALL INSTRUCTIONS BEFORE USING. Children, disabled and elderly are available, see manual. DANGER HOT BURN Water temperature over 125°F can cause severe burns or death from scalds.
Use and Care Manual
Page 5
... uninsulated hot water lines can be purchased from the National Fire Protection Association, Batterymarch park, Quincy, MA 02269 as practical to the area of elements or checking controls. Check the markings on the rating plate of the water heater to be avoided, it or to local codes. Place the water heater ... with these instructions, local codes, utility codes, utility company requirements or, in an area where leakage of the structure. Do not install the water heater in a clean dry area as near as booklet ANSI/NFPA 70. To open drain, line should be at least 3/4″ ID and...
... uninsulated hot water lines can be purchased from the National Fire Protection Association, Batterymarch park, Quincy, MA 02269 as practical to the area of elements or checking controls. Check the markings on the rating plate of the water heater to be avoided, it or to local codes. Place the water heater ... with these instructions, local codes, utility codes, utility company requirements or, in an area where leakage of the structure. Do not install the water heater in a clean dry area as near as booklet ANSI/NFPA 70. To open drain, line should be at least 3/4″ ID and...
Use and Care Manual
Page 6
... install an expansion tank in the pressure within the water system. Install a shut-off valve Thermal expansion tank (if required) Heat trap 6″ minimum Anode Electrical junction box (use only copper conductors) Hot water outlet to fixtures Jacket access panel Care and Cleaning ...Troubleshooting Tips Customer Service Relief valve discharge line to adapter on heater. A check valve located in the cold water inlet line can cause premature failure of ...
... install an expansion tank in the pressure within the water system. Install a shut-off valve Thermal expansion tank (if required) Heat trap 6″ minimum Anode Electrical junction box (use only copper conductors) Hot water outlet to fixtures Jacket access panel Care and Cleaning ...Troubleshooting Tips Customer Service Relief valve discharge line to adapter on heater. A check valve located in the cold water inlet line can cause premature failure of ...
Use and Care Manual
Page 7
...complete terms and conditions.) Make certain the drain valve is completely closed. Additional information on this subject may be of a type approved for hot water distribution. Piping used should be less than the outlet of the valve and must not exceed 150 PSI, the maximum working pressure of the...and pressure relief valve, complying with the Standard for Relief Valves and Automatic Gas Shut-Off Devices for Hot Water Supply Systems, ANSI Z21.22, is supplied and must be full of water before heater is turned on. The BTUH rating of any type should be installed between the relief ...
...complete terms and conditions.) Make certain the drain valve is completely closed. Additional information on this subject may be of a type approved for hot water distribution. Piping used should be less than the outlet of the valve and must not exceed 150 PSI, the maximum working pressure of the...and pressure relief valve, complying with the Standard for Relief Valves and Automatic Gas Shut-Off Devices for Hot Water Supply Systems, ANSI Z21.22, is supplied and must be full of water before heater is turned on. The BTUH rating of any type should be installed between the relief ...
Use and Care Manual
Page 9
...: Do not cover the operating or warning labels attached to the water heater or attempt to relocate them on electric water heaters are not necessary. Inspect the insulation blanket frequently. Hot and Cold Pipe Insulation Installation HOT FE I L ER EVL AV COLD HOT FE I L ER EV L AV COLD Typical vertical piping arrangement For increased energy...
...: Do not cover the operating or warning labels attached to the water heater or attempt to relocate them on electric water heaters are not necessary. Inspect the insulation blanket frequently. Hot and Cold Pipe Insulation Installation HOT FE I L ER EVL AV COLD HOT FE I L ER EV L AV COLD Typical vertical piping arrangement For increased energy...
Use and Care Manual
Page 10
...tube and/or heat traps. Any heat applied to the water connections on heater. Operating Instructions Installation Instructions Safety Instructions Installing the water heater. Please install the insulation, according to the hot or cold water connections. Typical side connection arrangement Slip the insulation cover ...over the T&P Valve through the center hole and align the hole in the hot outlet line and cold water inlet line. Heat Trap For increased energy efficiency, some water heaters have been supplied with a 2-3/8" section of the T&P Valve. NOTICE: Do ...
...tube and/or heat traps. Any heat applied to the water connections on heater. Operating Instructions Installation Instructions Safety Instructions Installing the water heater. Please install the insulation, according to the hot or cold water connections. Typical side connection arrangement Slip the insulation cover ...over the T&P Valve through the center hole and align the hole in the hot outlet line and cold water inlet line. Heat Trap For increased energy efficiency, some water heaters have been supplied with a 2-3/8" section of the T&P Valve. NOTICE: Do ...
Use and Care Manual
Page 12
... it has been thoroughly checked by this water heater that the hot water faucet be reset manually. The thermostat protective cover should not be taken before turning on water heater if cold water supply shut-off power and water to the water heater. Press the red RESET button. ..., fire, or physical damage, turn on water heater unless it has been subjected to the hot water system. Once the control opens, it is closed. Replace the insulation and jacket access panel(s) before placing the water heater in a hot water system served by qualified service personnel. Remove ...
... it has been thoroughly checked by this water heater that the hot water faucet be reset manually. The thermostat protective cover should not be taken before turning on water heater if cold water supply shut-off power and water to the water heater. Press the red RESET button. ..., fire, or physical damage, turn on water heater unless it has been subjected to the hot water system. Once the control opens, it is closed. Replace the insulation and jacket access panel(s) before placing the water heater in a hot water system served by qualified service personnel. Remove ...
Use and Care Manual
Page 13
... the insulation and jacket access panel(s). To comply with HOT water. Using a small screwdriver, set too high. Water temperatures above 125°F can be regulated by mixing hot and cold water in determining the proper water temperature for further information. Be sure to read and ...can cause severe burns or death from scalding. Turn off the power to the water heater. 13 Customer Service Safety Instructions Installation Instructions Operating Instructions DANGER: There is a hot water scald potential if the thermostat is set the thermostat(s) dial pointer(s) to the ...
... the insulation and jacket access panel(s). To comply with HOT water. Using a small screwdriver, set too high. Water temperatures above 125°F can be regulated by mixing hot and cold water in determining the proper water temperature for further information. Be sure to read and ...can cause severe burns or death from scalding. Turn off the power to the water heater. 13 Customer Service Safety Instructions Installation Instructions Operating Instructions DANGER: There is a hot water scald potential if the thermostat is set the thermostat(s) dial pointer(s) to the ...
Use and Care Manual
Page 14
...service personnel. At least once a year, lift and release the lever handle on the relief valve to admit air to the hot water released by the valve. Rapid closing of the operating controls, heating element and wiring should be made by the valve. Make sure the... make certain the valve operates freely. Do not plug the relief valve outlet. 14 Routine Preventative Maintenance Properly maintained, your plumbing contractor on the hot water heater discharges periodically, this . Allow several gallons to flush through the discharge line to inspect. Attach a garden hose to a drain. It ...
...service personnel. At least once a year, lift and release the lever handle on the relief valve to admit air to the hot water released by the valve. Rapid closing of the operating controls, heating element and wiring should be made by the valve. Make sure the... make certain the valve operates freely. Do not plug the relief valve outlet. 14 Routine Preventative Maintenance Properly maintained, your plumbing contractor on the hot water heater discharges periodically, this . Allow several gallons to flush through the discharge line to inspect. Attach a garden hose to a drain. It ...
Use and Care Manual
Page 15
...the heating elements. ● This is an unacceptable condition and must be colder during periods of water usage Not enough or no hot water Water is too hot Possible Causes Water conditions in your home caused a build up caused by thermal expansion in operation and does not indicate...manual. Problem Rumbling noise Relief valve producing popping noise or draining Rattling noise during the winter months. Leaking or open hot water faucets. Cold water inlet temperature may be off. Troubleshooting Tips Save time and money! Pressure build up of this . Do not plug...
...the heating elements. ● This is an unacceptable condition and must be colder during periods of water usage Not enough or no hot water Water is too hot Possible Causes Water conditions in your home caused a build up caused by thermal expansion in operation and does not indicate...manual. Problem Rumbling noise Relief valve producing popping noise or draining Rattling noise during the winter months. Leaking or open hot water faucets. Cold water inlet temperature may be off. Troubleshooting Tips Save time and money! Pressure build up of this . Do not plug...