...rear wall. Blower should be in diagram. Receptacle Location: Install an approved junction box within the width dimensions. Order part number JXCK89 from your Monogram® or GE® appliance questions, visit our website at least 10-1/2" ... Electrical cable is required Dimension and installation information are approved for island or peninsula installation. PP9830SJ GE Profile™ Series 30" Downdraft Electric Cooktop Dimensions and Installation Information KW RATING Wall Installation: Wall 240V 9.1 208V 6.9 installations require 25" countertop depth. When cabinet...
...rear wall. Blower should be in diagram. Receptacle Location: Install an approved junction box within the width dimensions. Order part number JXCK89 from your Monogram® or GE® appliance questions, visit our website at least 10-1/2" ... Electrical cable is required Dimension and installation information are approved for island or peninsula installation. PP9830SJ GE Profile™ Series 30" Downdraft Electric Cooktop Dimensions and Installation Information KW RATING Wall Installation: Wall 240V 9.1 208V 6.9 installations require 25" countertop depth. When cabinet...
Quick Specs
Page 2
...Wall to Roof Direct to outside. For satisfactory performance the duct run possible, with damper. PP9830SJ GE Profile™ Series 30" Downdraft Electric Cooktop Dimensions and Installation Information Installing the Ductwork: Use galvanized or aluminum duct in specifying type and schedule of all duct used. ... fittings as possible. Local building code must be used if installing under a poured concrete slab. For answers to your Monogram® or GE® appliance questions, visit our website at geappliances.com or call GE Answer Center® service, 800.626.2000. PVC duct...
...Wall to Roof Direct to outside. For satisfactory performance the duct run possible, with damper. PP9830SJ GE Profile™ Series 30" Downdraft Electric Cooktop Dimensions and Installation Information Installing the Ductwork: Use galvanized or aluminum duct in specifying type and schedule of all duct used. ... fittings as possible. Local building code must be used if installing under a poured concrete slab. For answers to your Monogram® or GE® appliance questions, visit our website at geappliances.com or call GE Answer Center® service, 800.626.2000. PVC duct...
Use and Care Manual
Page 1
... 9 For Best Results 9 Care and Cleaning Cleaning The Cooktop 10 Cleaning the Glass Cooktop 11 Installation Instructions. . . . . .13 Troubleshooting Tips 25 Owner's Manual & Installation Instructions PP9830 For a Spanish version of the vent chamber. 49-80635-1 03-15 GE Para consultar una version en español de este manual de instrucciones, visite nuestro...
... 9 For Best Results 9 Care and Cleaning Cleaning The Cooktop 10 Cleaning the Glass Cooktop 11 Installation Instructions. . . . . .13 Troubleshooting Tips 25 Owner's Manual & Installation Instructions PP9830 For a Spanish version of the vent chamber. 49-80635-1 03-15 GE Para consultar una version en español de este manual de instrucciones, visite nuestro...
Use and Care Manual
Page 2
... cooktop. Ŷ 'RQRWKHDWXQRSHQHGIRRGFRQWDLQHUV3UHVVXUH could build up (replacement) air system in accordance with the provided installation instructions. Ŷ 'RQRWDWWHPSWWRUHSDLURUUHSODFHDQ\SDUWRI your range unless it is in accordance with local ...WKH1DWLRQDO)LUH3URWHFWLRQ $VVRFLDWLRQ1)3$ WKH$PHULFDQ6RFLHW\IRU +HDWLQJ5HIULJHUDWLRQDQG$LU&RQGLWLRQLQJ $6+5$( DQGWKHORFDOFRGHDXWKRULWLHVZKHQ applicable, install any part of the appliance may result in this manual. READ ALL INSTRUCTIONS BEFORE USING. CAUTION Ŷ :'RQRWVWRUHLWHPVRI...
... cooktop. Ŷ 'RQRWKHDWXQRSHQHGIRRGFRQWDLQHUV3UHVVXUH could build up (replacement) air system in accordance with the provided installation instructions. Ŷ 'RQRWDWWHPSWWRUHSDLURUUHSODFHDQ\SDUWRI your range unless it is in accordance with local ...WKH1DWLRQDO)LUH3URWHFWLRQ $VVRFLDWLRQ1)3$ WKH$PHULFDQ6RFLHW\IRU +HDWLQJ5HIULJHUDWLRQDQG$LU&RQGLWLRQLQJ $6+5$( DQGWKHORFDOFRGHDXWKRULWLHVZKHQ applicable, install any part of the appliance may result in this manual. READ ALL INSTRUCTIONS BEFORE USING. CAUTION Ŷ :'RQRWVWRUHLWHPVRI...
Use and Care Manual
Page 13
..."If you have questions, call 800.GE.CARES or visit our website at the service panel and lock the service disconnecting means to Installer - Observe all applicable codes and standards, including fire-rated construction. Before beginning the installation, switch power off at : GEAppliances....local code authorities. Keep these instructions for Heating, Refrigeration and Air Conditioning (ASHRAE) and the local code authorities. when applicable, install any make up (replacement) air system in accordance with all governing codes and ordinances. • Note to prevent power from being...
..."If you have questions, call 800.GE.CARES or visit our website at the service panel and lock the service disconnecting means to Installer - Observe all applicable codes and standards, including fire-rated construction. Before beginning the installation, switch power off at : GEAppliances....local code authorities. Keep these instructions for Heating, Refrigeration and Air Conditioning (ASHRAE) and the local code authorities. when applicable, install any make up (replacement) air system in accordance with all governing codes and ordinances. • Note to prevent power from being...
Use and Care Manual
Page 14
nuts with lock washers attached) 14 Blower Plenum Vent Filter 49-80635-1 INSTALLATION INSTRUCTIONS Installation Instructions UNPACKING YOUR COOKTOP Check to the appliance once the appliance has been turned on control knobs (if applicable), adhesive tape, wire ties, cardboard and ... Sponge Foam Gasket Tape CAUTION: DO NOT LIFT FROM VENT OPENING OR BUMP GLASS CAUTION: GLASS IS FRAGILE DO NOT BUMP EDGE OF GLASS DURING INSTALLATION Blower Assembly and (4) Mounting Nuts (10-32 keps - This will include tape on and surfaces have been removed.
nuts with lock washers attached) 14 Blower Plenum Vent Filter 49-80635-1 INSTALLATION INSTRUCTIONS Installation Instructions UNPACKING YOUR COOKTOP Check to the appliance once the appliance has been turned on control knobs (if applicable), adhesive tape, wire ties, cardboard and ... Sponge Foam Gasket Tape CAUTION: DO NOT LIFT FROM VENT OPENING OR BUMP GLASS CAUTION: GLASS IS FRAGILE DO NOT BUMP EDGE OF GLASS DURING INSTALLATION Blower Assembly and (4) Mounting Nuts (10-32 keps - This will include tape on and surfaces have been removed.
Use and Care Manual
Page 15
...circuit breaker or time delay fuses. A copy of local electrical codes, the National Electrical Code, ANSI/ NFPA No. 70 - INSTALLATION INSTRUCTIONS Installation Instructions PREPARATION TOOLS AND MATERIALS YOU WILL NEED • Cut resistant gloves • Saw • Flat-blade screwdriver • Electrician...• 3/4" flexible conduit* • Electrical wire per local code* • Wire nuts* • Ductwork *NOTE: Electrical installation kit JXCK89 may be ordered separately and includes all the parts necessary to connect the cooktop to typical rough-in NEW CONSTRUCTION AND ...
...circuit breaker or time delay fuses. A copy of local electrical codes, the National Electrical Code, ANSI/ NFPA No. 70 - INSTALLATION INSTRUCTIONS Installation Instructions PREPARATION TOOLS AND MATERIALS YOU WILL NEED • Cut resistant gloves • Saw • Flat-blade screwdriver • Electrician...• 3/4" flexible conduit* • Electrical wire per local code* • Wire nuts* • Ductwork *NOTE: Electrical installation kit JXCK89 may be ordered separately and includes all the parts necessary to connect the cooktop to typical rough-in NEW CONSTRUCTION AND ...
Use and Care Manual
Page 16
... least 6" from the side edge of the cabinets. height from residence wiring to junction box according to reduce the hazards caused by installing a range hood that projects horizontally a minimum of 5 inches beyond the bottom of the cooktop to accommodate the unit. If cabinetry ... require modifications. Preparing a cabinet that is against a wall In some cabinets may be scooped or cut down 53/4" to be installed properly. EXCEPTION: Installation of any cabinet not directly above the cooktop unit, if possible, in a cabinet at least 30" wide. Run conductors from ...
... least 6" from the side edge of the cabinets. height from residence wiring to junction box according to reduce the hazards caused by installing a range hood that projects horizontally a minimum of 5 inches beyond the bottom of the cooktop to accommodate the unit. If cabinetry ... require modifications. Preparing a cabinet that is against a wall In some cabinets may be scooped or cut down 53/4" to be installed properly. EXCEPTION: Installation of any cabinet not directly above the cooktop unit, if possible, in a cabinet at least 30" wide. Run conductors from ...
Use and Care Manual
Page 17
... Wall Venting Downward Venting A 1/2" wide flat area is required around the edge of flexible ducting is available at your installation. NOTE: Illustrations are for support of flexible ducting is cut countertop opening according to the dimensions shown in the illustration.... Cut hole in cabinet wall or floor as possible. 6" Max. INSTALLATION INSTRUCTIONS Installation Instructions CABINET PREPARATION CUTOUTS 4 PREPARING THE COUNTERTOP The countertop must be 205ø8" in order to accommodate cooktop depth. 5...
... Wall Venting Downward Venting A 1/2" wide flat area is required around the edge of flexible ducting is available at your installation. NOTE: Illustrations are for support of flexible ducting is cut countertop opening according to the dimensions shown in the illustration.... Cut hole in cabinet wall or floor as possible. 6" Max. INSTALLATION INSTRUCTIONS Installation Instructions CABINET PREPARATION CUTOUTS 4 PREPARING THE COUNTERTOP The countertop must be 205ø8" in order to accommodate cooktop depth. 5...
Use and Care Manual
Page 18
... layout. PVC Coupling 6″ (15 cm) Dia. Flow Duct Tape Over Seam and Screw Screw 18 49-80635-1 Maintain a constant duct size. 3. If needed, install any leaks. 4. PVC Sewer Pipe Elbow 16″ (40.6 cm) Max. 6″ (15 cm) Dia. PVC Sewer Pipe 30′-0″ (9.14 m) ...Max. Visit GEAppliances.com for available makeup air solutions. PVC Sewer Pipe • Install ductwork so the piece of duct nearest the downdraft unit slots INTO the next piece of flexible ducting. Inside wall cabinet Up inside wall to...
... layout. PVC Coupling 6″ (15 cm) Dia. Flow Duct Tape Over Seam and Screw Screw 18 49-80635-1 Maintain a constant duct size. 3. If needed, install any leaks. 4. PVC Sewer Pipe Elbow 16″ (40.6 cm) Max. 6″ (15 cm) Dia. PVC Sewer Pipe 30′-0″ (9.14 m) ...Max. Visit GEAppliances.com for available makeup air solutions. PVC Sewer Pipe • Install ductwork so the piece of duct nearest the downdraft unit slots INTO the next piece of flexible ducting. Inside wall cabinet Up inside wall to...
Use and Care Manual
Page 19
... • Butt the foam gasket tape ends together at each corner without overlapping. • Trim the foam gasket tape to install the foam gasket tape on the bottom side of the cooktop glass as shown. Center vent shipping block - Locate the reflective tape... provide level support. It protects the bottom edge of the glass from the shipping box. INSTALLATION INSTRUCTIONS Installation Instructions UNPACKING THE COOKTOP/INSTALLING THE GASKET 8 INSTALLING THE FOAM GASKET Do not install the cooktop into the countertop without stretching. • Mitre cut outside corners of foam gasket...
... • Butt the foam gasket tape ends together at each corner without overlapping. • Trim the foam gasket tape to install the foam gasket tape on the bottom side of the cooktop glass as shown. Center vent shipping block - Locate the reflective tape... provide level support. It protects the bottom edge of the glass from the shipping box. INSTALLATION INSTRUCTIONS Installation Instructions UNPACKING THE COOKTOP/INSTALLING THE GASKET 8 INSTALLING THE FOAM GASKET Do not install the cooktop into the countertop without stretching. • Mitre cut outside corners of foam gasket...
Use and Care Manual
Page 20
...Turn thumb screw until it LQWRSRVLWLRQ*ODVVLVIUDJLOH³GRQRWDOORZLWWRGURSRQWRWKH countertop. INSTALLATION INSTRUCTIONS Installation Instructions INSTALLING THE COOKTOP 9 INSTALLING THE COOKTOP: CAUTION: DO NOT LIFT FROM VENT OPENING. Support from the underside and lower slowly. NOTE: Do ... into position. Do this on the other side. visually inspect the cooktop and counter, appearance or alignment concerns. 10 INSTALLING THE OPTIONAL INSTALLATION BRACKETS NOTE: Check for glass flatness in countertop; Lift the cooktop by the glass side edges as shown. Lower the...
...Turn thumb screw until it LQWRSRVLWLRQ*ODVVLVIUDJLOH³GRQRWDOORZLWWRGURSRQWRWKH countertop. INSTALLATION INSTRUCTIONS Installation Instructions INSTALLING THE COOKTOP 9 INSTALLING THE COOKTOP: CAUTION: DO NOT LIFT FROM VENT OPENING. Support from the underside and lower slowly. NOTE: Do ... into position. Do this on the other side. visually inspect the cooktop and counter, appearance or alignment concerns. 10 INSTALLING THE OPTIONAL INSTALLATION BRACKETS NOTE: Check for glass flatness in countertop; Lift the cooktop by the glass side edges as shown. Lower the...
Use and Care Manual
Page 21
...) 49-80635-1 21 Push up on the plenum until the stops on the plenum contact the bottom of the cooktop. NOTE: See Step 13 for installing the transition duct to the cooktop, from the top side, using the four (4) screws provided. From the vent opening in Steps 6 and 7. Further secure ...the plenum to the blower. Slide the four threaded studs on the side of the blower housing into place.) Install 2 screws 12 INSTALLING THE BLOWER TO THE PLENUM Orient the blower discharge opening in the bottom of the cooktop, and snap the plenum into place. (You may...
...) 49-80635-1 21 Push up on the plenum until the stops on the plenum contact the bottom of the cooktop. NOTE: See Step 13 for installing the transition duct to the cooktop, from the top side, using the four (4) screws provided. From the vent opening in Steps 6 and 7. Further secure ...the plenum to the blower. Slide the four threaded studs on the side of the blower housing into place.) Install 2 screws 12 INSTALLING THE BLOWER TO THE PLENUM Orient the blower discharge opening in the bottom of the cooktop, and snap the plenum into place. (You may...
Use and Care Manual
Page 22
... a blower transition duct for reinstallation later. 5-pin connectors • Fold all wires into the electrical enclosure. Secure all downward duct installations to connect to assure an airtight seal. 14 BLOWER ELECTRICAL CONNECTIONS • Loosen the two screws and remove and discard the sheet ... rectangle to 6" round transition duct is available at your local building supply store. • Connect the 5-pin plug on other side) Install the transition duct to the blower outlet. Secure the enclosure with duct tape to 6" round standard ductwork. Screws Screw (on the blower ...
... a blower transition duct for reinstallation later. 5-pin connectors • Fold all wires into the electrical enclosure. Secure all downward duct installations to connect to assure an airtight seal. 14 BLOWER ELECTRICAL CONNECTIONS • Loosen the two screws and remove and discard the sheet ... rectangle to 6" round transition duct is available at your local building supply store. • Connect the 5-pin plug on other side) Install the transition duct to the blower outlet. Secure the enclosure with duct tape to 6" round standard ductwork. Screws Screw (on the blower ...
Use and Care Manual
Page 23
...and attach it to the cover. Verify with this appliance are UL-recognized for connection to large gauge household wiring. be installed before reinstalling the wiring cover. Power Supply Anti-Short Leads Bushing Conduit Bushing (Fully Seated) Conduit Connector Conduit Cover 49-80635...* Model # Voltage Frequency KW PP989 120/240V 60Hz 9.1KW 120/208V 60Hz 6.9KW *For reference only. INSTALLATION INSTRUCTIONS Installation Instructions ELECTRICAL CONNECTIONS 16 BEFORE MAKING ELECTRICAL CONNECTIONS Note to Electrician: The power leads supplied with product rating plate.
...and attach it to the cover. Verify with this appliance are UL-recognized for connection to large gauge household wiring. be installed before reinstalling the wiring cover. Power Supply Anti-Short Leads Bushing Conduit Bushing (Fully Seated) Conduit Connector Conduit Cover 49-80635...* Model # Voltage Frequency KW PP989 120/240V 60Hz 9.1KW 120/208V 60Hz 6.9KW *For reference only. INSTALLATION INSTRUCTIONS Installation Instructions ELECTRICAL CONNECTIONS 16 BEFORE MAKING ELECTRICAL CONNECTIONS Note to Electrician: The power leads supplied with product rating plate.
Use and Care Manual
Page 24
...must use with separate ground. Connect the green and white leads of the cooktop and the power supply to each other . INSTALLATION INSTRUCTIONS Installation Instructions ELECTRICAL CONNECTIONS 18 MAKING ELECTRICAL CONNECTIONS Effective January 1, 1996, the National Electrical Code requires that new, but not existing...a four-conductor connection to the power supply and branch circuit neutral leads, which are white or gray. 24 49-80635-1 When installing an electric range in new construction, follow the instructions in a mobile home, or • When local codes do not permit ...
...must use with separate ground. Connect the green and white leads of the cooktop and the power supply to each other . INSTALLATION INSTRUCTIONS Installation Instructions ELECTRICAL CONNECTIONS 18 MAKING ELECTRICAL CONNECTIONS Effective January 1, 1996, the National Electrical Code requires that new, but not existing...a four-conductor connection to the power supply and branch circuit neutral leads, which are white or gray. 24 49-80635-1 When installing an electric range in new construction, follow the instructions in a mobile home, or • When local codes do not permit ...
Use and Care Manual
Page 25
Vent Filter Vent Chamber • Make sure it rests, at an angle, on the supports in place. • Place the filter diagonally through the vent opening . INSTALLATION INSTRUCTIONS Installation Instructions FINAL ASSEMBLY 19 INSTALL DOWNDRAFT FILTER VENT GRILLE Do not operate the vent without the filter in the vent opening. • Carefully place the vent grille onto the downdraft opening . CHECK OPERATION OF DOWNDRAFT • Turn the vent fan speed control to HI, MED and LO to make sure all speeds operate correctly. 49-80635-1 25
Vent Filter Vent Chamber • Make sure it rests, at an angle, on the supports in place. • Place the filter diagonally through the vent opening . INSTALLATION INSTRUCTIONS Installation Instructions FINAL ASSEMBLY 19 INSTALL DOWNDRAFT FILTER VENT GRILLE Do not operate the vent without the filter in the vent opening. • Carefully place the vent grille onto the downdraft opening . CHECK OPERATION OF DOWNDRAFT • Turn the vent fan speed control to HI, MED and LO to make sure all speeds operate correctly. 49-80635-1 25