Manual
Page 6
BMC command format table Preparation [1] Get BIOS image file "image.RBU" of target system. [2] Make sure target system BMC is live. [3] Get BMC IP address of target system. [4] Download TFTP service application for Linux client PC (Please users set up their own TFTP server.). [6] Get ipmitool. 2.2. GIGA -BYTE TECHNOLOGY CO., LTD. 2. Tftpd64.exe/Tftpd32.exe through BMC Command-line interface 2.1. Update BIOS through free download). [5] Setup TFTP server for Windows client PC (e.g.
BMC command format table Preparation [1] Get BIOS image file "image.RBU" of target system. [2] Make sure target system BMC is live. [3] Get BMC IP address of target system. [4] Download TFTP service application for Linux client PC (Please users set up their own TFTP server.). [6] Get ipmitool. 2.2. GIGA -BYTE TECHNOLOGY CO., LTD. 2. Tftpd64.exe/Tftpd32.exe through BMC Command-line interface 2.1. Update BIOS through free download). [5] Setup TFTP server for Windows client PC (e.g.
Manual
Page 10
....RBU [5] Check upload status e.g. GIGA -BYTE TECHNOLOGY CO., LTD. [4] Upload "image.RBU" through TFTP service application. e.g. ipmitool -H 10.1.27.150 -U admin -P password raw 0x2e 0x21 0x0a 0x3c 0x00 0x0e Response: 0a 3c 00 01 00 Byte 1 = 00h : Command Completed Normally Byte 2 = 01h : Copying To Scratch Byte 3 = 00h : Update Progress (If byte 2 is 06, this data is available...
....RBU [5] Check upload status e.g. GIGA -BYTE TECHNOLOGY CO., LTD. [4] Upload "image.RBU" through TFTP service application. e.g. ipmitool -H 10.1.27.150 -U admin -P password raw 0x2e 0x21 0x0a 0x3c 0x00 0x0e Response: 0a 3c 00 01 00 Byte 1 = 00h : Command Completed Normally Byte 2 = 01h : Copying To Scratch Byte 3 = 00h : Update Progress (If byte 2 is 06, this data is available...
Manual
Page 3
... Console (Linux 13 1-5-1 Tomcat Installation Procedure 13 1-5-2 PostgreSQL Installation Procedure 13 1-5-3 Restore dbRMCv0XX.backup 14 1-5-4 pgadminIII Installation Procedure (Optional 15 1-5-5 Login Gigabyte Server Management Console 16 Chapter 2 Gigabyte Server Management Console 17 2-1 Overview...17 2-2 Enter Gigabyte Server Management Console 18 2-2-1 Node Info...18 2-2-1-1 Node ID...20 Power Consumption...20 SEL ...21 Node Detail...21 Chassis ...22 Sensor ...23 Trap IP Destination List...24 Platform Events...25 BMC Update...26 BIOS Update...26 Power Limit...27 IPv6 Configuration...
... Console (Linux 13 1-5-1 Tomcat Installation Procedure 13 1-5-2 PostgreSQL Installation Procedure 13 1-5-3 Restore dbRMCv0XX.backup 14 1-5-4 pgadminIII Installation Procedure (Optional 15 1-5-5 Login Gigabyte Server Management Console 16 Chapter 2 Gigabyte Server Management Console 17 2-1 Overview...17 2-2 Enter Gigabyte Server Management Console 18 2-2-1 Node Info...18 2-2-1-1 Node ID...20 Power Consumption...20 SEL ...21 Node Detail...21 Chassis ...22 Sensor ...23 Trap IP Destination List...24 Platform Events...25 BMC Update...26 BIOS Update...26 Power Limit...27 IPv6 Configuration...
Manual
Page 5
.... 1-2 Hardware Requirement Before using Gigabyte Server Management Console, please check your system for the following required configuration requirements: • System Processor: 2 GHz and above • System Memory: Minimum 4 GB RAM • Free Disk Space: 1000 GB at least • Node servers : 255 maximum 1-3 Software Requirement 1-3-1 Prerequisites on remote management server Supported Browsers: • Internet Explorer 9 or later • Google Chrome 39.0.2171.65 m or later • Mozilla Firefox 33.1.1 Operating System: • Windows...
.... 1-2 Hardware Requirement Before using Gigabyte Server Management Console, please check your system for the following required configuration requirements: • System Processor: 2 GHz and above • System Memory: Minimum 4 GB RAM • Free Disk Space: 1000 GB at least • Node servers : 255 maximum 1-3 Software Requirement 1-3-1 Prerequisites on remote management server Supported Browsers: • Internet Explorer 9 or later • Google Chrome 39.0.2171.65 m or later • Mozilla Firefox 33.1.1 Operating System: • Windows...
Manual
Page 16
rpm Initialize: /usr/pgsql-9.3/postgresql93-setup initdb Gigabyte Server Management Console - 16 - Open a browser and enter Database IP address localhost 2. Enter Database User Name postgres • This utility supported CentOS 6.3 or later version. • PostgreSQL must be execute in root authority. • In Fedora 19, you have to install package in the following: Locate and edit your distributions .repo file, located: vi /etc/yum.repos...
rpm Initialize: /usr/pgsql-9.3/postgresql93-setup initdb Gigabyte Server Management Console - 16 - Open a browser and enter Database IP address localhost 2. Enter Database User Name postgres • This utility supported CentOS 6.3 or later version. • PostgreSQL must be execute in root authority. • In Fedora 19, you have to install package in the following: Locate and edit your distributions .repo file, located: vi /etc/yum.repos...
Manual
Page 18
... selected ID to configure connected nodes in Help page. Status There are four type of Status: • Out of current remote client system. Gigabyte Server Management Console - 18 - 2-2 Enter Gigabyte Server Management Console After you successfully log into your Gigabyte Server Management Console, the Remote Management Console GUI appears. 2-2-1 Node Info Node Info displays the Node List information and Group Information of range (no monitoring) • Warning • Connected • Disconnected Node ID BMC IP BMC Connection Displays the connected Node ID...
... selected ID to configure connected nodes in Help page. Status There are four type of Status: • Out of current remote client system. Gigabyte Server Management Console - 18 - 2-2 Enter Gigabyte Server Management Console After you successfully log into your Gigabyte Server Management Console, the Remote Management Console GUI appears. 2-2-1 Node Info Node Info displays the Node List information and Group Information of range (no monitoring) • Warning • Connected • Disconnected Node ID BMC IP BMC Connection Displays the connected Node ID...
Manual
Page 19
Displays the Node power status. Displays the Node power limit status. Group Power Status Power Consumption Power Limit Note Displays the Node group information. There are three type of the menu tree from left window. Note for node status. - 19 - If a node is defined as specified group, user also can find the node group information in Group Info of power status: • ON • OFF • N/A Displays the Node power consumption support status. Gigabyte Server Management Console
Displays the Node power status. Displays the Node power limit status. Group Power Status Power Consumption Power Limit Note Displays the Node group information. There are three type of the menu tree from left window. Note for node status. - 19 - If a node is defined as specified group, user also can find the node group information in Group Info of power status: • ON • OFF • N/A Displays the Node power consumption support status. Gigabyte Server Management Console
Manual
Page 20
Power Consumption Parameter Power Consumption Decription/Resulting Action Displays the power consumption of a remote node system. When you finish the configuration, click OK. Gigabyte Server Management Console 2-2-1-1 Node ID Sensor Monitoring Parameter Sensor Monitoring Decription/Resulting Action Displays the Temperatures sensors of a remote node system. Select Domain ID from the drop-down list, when you finish the configuration, click OK. - 20 -
Power Consumption Parameter Power Consumption Decription/Resulting Action Displays the power consumption of a remote node system. When you finish the configuration, click OK. Gigabyte Server Management Console 2-2-1-1 Node ID Sensor Monitoring Parameter Sensor Monitoring Decription/Resulting Action Displays the Temperatures sensors of a remote node system. Select Domain ID from the drop-down list, when you finish the configuration, click OK. - 20 -
Manual
Page 22
Chassis Parameter Chassis Decription/Resulting Action Chassis Power Control: Power control function to power on system. Define the timeout from the drop-down list, when you finish the configuration, click Apply. When you finish the configuration, click ON to power on or power off the system. Click OFF to update current system power control status. Gigabyte Server Management Console - 22 - Click Refresh to power off /cycle and hard reset the remote host system. Set Chassis Identify: Define timeout to power on /off system.
Chassis Parameter Chassis Decription/Resulting Action Chassis Power Control: Power control function to power on system. Define the timeout from the drop-down list, when you finish the configuration, click Apply. When you finish the configuration, click ON to power on or power off the system. Click OFF to update current system power control status. Gigabyte Server Management Console - 22 - Click Refresh to power off /cycle and hard reset the remote host system. Set Chassis Identify: Define timeout to power on /off system.
Manual
Page 31
... you finish the configuration, click Apply. Displays the connected Node SEL information. Displays the grouped Node FRU information. When you finish the configuration, click ON to power on system. Click Refresh to update current Node FRU LIST. Set Chassis Identify: Define timeout to power on or power off /cycle and hard reset the remote host system. Click on /off the system. Gigabyte Server Management Console Chassis Power Control: Power control function to power on selected...
... you finish the configuration, click Apply. Displays the connected Node SEL information. Displays the grouped Node FRU information. When you finish the configuration, click ON to power on system. Click Refresh to update current Node FRU LIST. Set Chassis Identify: Define timeout to power on or power off /cycle and hard reset the remote host system. Click on /off the system. Gigabyte Server Management Console Chassis Power Control: Power control function to power on selected...
Manual
Page 32
... specified device from the use of firmware. IPv6 has a significantly larger address space than IPv4. A platform event filter (PEF) can be able to indicate the health status of node power consumption/fan speed/temperature. BMC Update Guide in Help page. For detail intruction of platform event alerts globally by clicking Global Alerting Enable. To re-configure the power limit value, click Deactivate. Enable/Disable IPv6 Configuration. When you finish the configuration, click Update. Gigabyte Server Management Console...
... specified device from the use of firmware. IPv6 has a significantly larger address space than IPv4. A platform event filter (PEF) can be able to indicate the health status of node power consumption/fan speed/temperature. BMC Update Guide in Help page. For detail intruction of platform event alerts globally by clicking Global Alerting Enable. To re-configure the power limit value, click Deactivate. Enable/Disable IPv6 Configuration. When you finish the configuration, click Update. Gigabyte Server Management Console...
Manual
Page 34
When the log matches the predefined alert, the system sends out the notification automatically, if it is pre-configured. Gigabyte Server Management Console - 34 - 2-2-4 Log Dump Log Dump records the event when sensor has an abnormal state. To refresh the event log, just click Refresh. • To diagnose a error, please refer 3-1 Exception List for detail decription or troubleshooting. To clear the event log, just click Clear Log. To download the event log, just click Download.
When the log matches the predefined alert, the system sends out the notification automatically, if it is pre-configured. Gigabyte Server Management Console - 34 - 2-2-4 Log Dump Log Dump records the event when sensor has an abnormal state. To refresh the event log, just click Refresh. • To diagnose a error, please refer 3-1 Exception List for detail decription or troubleshooting. To clear the event log, just click Clear Log. To download the event log, just click Download.
Manual
Page 38
... IP/enable destination fail Get platform events fail Get IPv6 trap IP/enable destination fail Match rack node info fail Match RMC/BMC IP fail Get FRU fail Save Event Log to log file fail Copy catalina file fail Close file channel fail Get power status fail Send chassis command fail Set IPv6 enable/disable configuration fail Get power reading fail Get CPU temperature fail Set boot option fail Set chassis identify fail Power limit deactivate Description Network is not connected or BMC is busy. Network is not connected or BMC is busy. Please restart tomcat server. Network...
... IP/enable destination fail Get platform events fail Get IPv6 trap IP/enable destination fail Match rack node info fail Match RMC/BMC IP fail Get FRU fail Save Event Log to log file fail Copy catalina file fail Close file channel fail Get power status fail Send chassis command fail Set IPv6 enable/disable configuration fail Get power reading fail Get CPU temperature fail Set boot option fail Set chassis identify fail Power limit deactivate Description Network is not connected or BMC is busy. Network is not connected or BMC is busy. Please restart tomcat server. Network...
Manual
Page 2
... Management Network Configuration 6 Using the Web UI...8 Gigabyte Content Management System Console Overview 9 Enter Gigabyte Content Management System Console 10 Properties ...10 Configuration ...11 Network...11 Network Security ...12 Security ...13 Users ...14 Services ...15 IPMI ...16 Time Setting ...18 Language ...19 Sessions ...20 LDAP ...21 Updates ...22 Utilities ...23 Server Information ...24 General Setting...24 Power Control ...25 Power Consumption ...26 System Event Log ...27 Event Management ...28 Platform Event ...28 Trap Settings ...29 Email Settings ...30 Serial Over LAN...
... Management Network Configuration 6 Using the Web UI...8 Gigabyte Content Management System Console Overview 9 Enter Gigabyte Content Management System Console 10 Properties ...10 Configuration ...11 Network...11 Network Security ...12 Security ...13 Users ...14 Services ...15 IPMI ...16 Time Setting ...18 Language ...19 Sessions ...20 LDAP ...21 Updates ...22 Utilities ...23 Server Information ...24 General Setting...24 Power Control ...25 Power Consumption ...26 System Event Log ...27 Event Management ...28 Platform Event ...28 Trap Settings ...29 Email Settings ...30 Serial Over LAN...
Manual
Page 5
...; Out-of-band monitoring and control for sever management over LAN. FRU information report includes main board part number, product name, and manufacturer, etc.) Health status/Hardware monitoring report. Events log, view, and clear. Event notification via PET (Platform Event Trap). Platform Event Filtering (PEF) to take selected action for selected events. Chassis management includes power control and status report, front panel buttons and LEDs control. Support multi-session user, and alert...
...; Out-of-band monitoring and control for sever management over LAN. FRU information report includes main board part number, product name, and manufacturer, etc.) Health status/Hardware monitoring report. Events log, view, and clear. Event notification via PET (Platform Event Trap). Platform Event Filtering (PEF) to take selected action for selected events. Chassis management includes power control and status report, front panel buttons and LEDs control. Support multi-session user, and alert...
Manual
Page 6
... Recommended Version 8 Update 25 or later version (file size: ~ 623KB) Install Java Tool Please follow the instruction to replace. 9. Click see all applications including the browser. 11. Click Yes to install Java in Windows operating system. 1. Click Download on the middle of the file is JavaSetup8u25.exe Size is approximately 623KB. 10. Select the operating system you are using. 6. Software Install Prerequisites on remote management...
... Recommended Version 8 Update 25 or later version (file size: ~ 623KB) Install Java Tool Please follow the instruction to replace. 9. Click see all applications including the browser. 11. Click Yes to install Java in Windows operating system. 1. Click Download on the middle of the file is JavaSetup8u25.exe Size is approximately 623KB. 10. Select the operating system you are using. 6. Software Install Prerequisites on remote management...
Manual
Page 7
Define Configuration Address source to BIOS setup menu. 2. Go to DynamicBmcDhcp or Static. 5. Save and Exit. 6. Select Server Management. 3. The BMC IP Address will appear on the IPv4 Address parameter. 6 Select BMC network Configuration 4. Gigabyte Content Management Network Configuration Please follow the instruction to enable the console redirection function. 1.
Define Configuration Address source to BIOS setup menu. 2. Go to DynamicBmcDhcp or Static. 5. Save and Exit. 6. Select Server Management. 3. The BMC IP Address will appear on the IPv4 Address parameter. 6 Select BMC network Configuration 4. Gigabyte Content Management Network Configuration Please follow the instruction to enable the console redirection function. 1.
Manual
Page 12
... configure the BMC related settings through the BMC or NIC2 port. (Backup Mode) When you finish configuration, click Apply Change. Shared Mode When set to take effect immediately, click "Refresh" to Dedicate Mode, you can configure the BMC related settings through the BMC port. 2. Select the Network Mode from the drop-down list. 1. Please note that the changes may not take effect of changes. 11 Dedicate Mode When set to Failover Mode, you can view...
... configure the BMC related settings through the BMC or NIC2 port. (Backup Mode) When you finish configuration, click Apply Change. Shared Mode When set to take effect immediately, click "Refresh" to Dedicate Mode, you can configure the BMC related settings through the BMC port. 2. Select the Network Mode from the drop-down list. 1. Please note that the changes may not take effect of changes. 11 Dedicate Mode When set to Failover Mode, you can view...
Manual
Page 17
... BMC commands are allowed to manage the system from the drop-down list. IPMI Serial There are allowed, including configuration commands. Once the connection mode is communicating over. 16 The Connection Mode Settings allows user to select the Console redirection type and to be executed. Privilege levels tell the BMC which commands are allowed, except for configuration commands that the Administrator is set, select the Baud Rate and Flow Control from a remote location...
... BMC commands are allowed to manage the system from the drop-down list. IPMI Serial There are allowed, including configuration commands. Once the connection mode is communicating over. 16 The Connection Mode Settings allows user to select the Console redirection type and to be executed. Privilege levels tell the BMC which commands are allowed, except for configuration commands that the Administrator is set, select the Baud Rate and Flow Control from a remote location...