... detector or soap-and-water solution 11.Measuring tape 12.Reamer Drawing for indoor and outdoor 4 1 E Drain hose Drain hose F Heating insulating material 5 4X50 Steel nail, cement 6 G Piping hole cover more than 10cm 6 4X25 Screw Plastic cap 4 7 Cover 1 8 Cushion 4 9 Pipe supporting plate 1 Arrangement of Room Air Conditioner Read this manual before installation Explain sufficiently the operating means to the user according to G in the figure are the parts numbers. Installation Manual of piping directions Rear left Left...
... detector or soap-and-water solution 11.Measuring tape 12.Reamer Drawing for indoor and outdoor 4 1 E Drain hose Drain hose F Heating insulating material 5 4X50 Steel nail, cement 6 G Piping hole cover more than 10cm 6 4X25 Screw Plastic cap 4 7 Cover 1 8 Cushion 4 9 Pipe supporting plate 1 Arrangement of Room Air Conditioner Read this manual before installation Explain sufficiently the operating means to the user according to G in the figure are the parts numbers. Installation Manual of piping directions Rear left Left...
User Manual
Page 2
... can be connected with nails or wires in operation. Power Source Before inserting power plug into receptacle, check the voltage without fail. Do not extend the cable by heat or steam generated in the vicinity, where inlet and outlet of fixing the remote controller on a wall, place where the indoor unit can be spread in the room are not increased. Place, nearby...
... can be connected with nails or wires in operation. Power Source Before inserting power plug into receptacle, check the voltage without fail. Do not extend the cable by heat or steam generated in the vicinity, where inlet and outlet of fixing the remote controller on a wall, place where the indoor unit can be spread in the room are not increased. Place, nearby...
User Manual
Page 3
Install piping hole cover and seal it off with putty after installation Indoor side Wall hole 60mm Outdoor side Thickness of wall (Section of wall hole) G Piping hole pipe 3.Installation of the Indoor Unit Drawing of pipe [ Rear piping ] Draw pipes and the drain hose, then fasten them with the adhesive tape [ Left Left-rear piping ] In case of left side piping, cut away, with a nipper, the lid for the plate to the fixed mounting bar. Indoor unit Indoor unit 1.Fitting...
Install piping hole cover and seal it off with putty after installation Indoor side Wall hole 60mm Outdoor side Thickness of wall (Section of wall hole) G Piping hole pipe 3.Installation of the Indoor Unit Drawing of pipe [ Rear piping ] Draw pipes and the drain hose, then fasten them with the adhesive tape [ Left Left-rear piping ] In case of left side piping, cut away, with a nipper, the lid for the plate to the fixed mounting bar. Indoor unit Indoor unit 1.Fitting...
User Manual
Page 4
... indoor/outdoor electric cable from outside the room cable into the dent of heat insulation materials of indoor unit, then take off wiring cover by protecting tape. [Other direction piping] Cut away, with refrigerant oil and connect pipes. In order to fix the body onto the mounting plate,hold up the body aslant from side to side to crash pipes. Insert the drain hose into left piping Heat insulation material Drain hose Piping Indoor/outdoor electric...
... indoor/outdoor electric cable from outside the room cable into the dent of heat insulation materials of indoor unit, then take off wiring cover by protecting tape. [Other direction piping] Cut away, with refrigerant oil and connect pipes. In order to fix the body onto the mounting plate,hold up the body aslant from side to side to crash pipes. Insert the drain hose into left piping Heat insulation material Drain hose Piping Indoor/outdoor electric...
User Manual
Page 5
.... The wiring method should be all-pole switch and the distance between its service agent or a similar qualified person. The type of indoor and outdoor units carefully. If the fuse on PC board is not correct, proper operation can not be replaced by the manufacturer or its two contacts should be easily reached. 5. Indoor unit When connecting the cable before installing the indoor unit Insert the...
.... The wiring method should be all-pole switch and the distance between its service agent or a similar qualified person. The type of indoor and outdoor units carefully. If the fuse on PC board is not correct, proper operation can not be replaced by the manufacturer or its two contacts should be easily reached. 5. Indoor unit When connecting the cable before installing the indoor unit Insert the...
User Manual
Page 6
...indoor unit. shall not enter the pipe. 3.Connection Use the same method on terminal block and insert the plugs fully into terminal block, then tighten the screws. Loosen the screws on indoor unit. Insert the cable according to terminal number in the same manner as figure. (Note: Only for the installation of indoor and outdoor units 2.Connection of pipes To bend a pipe... not to crush the pipe Connecting the pipe of gas side first makes working easier. Outdoor unit Outdoor unit 1.Installation of Outdoor Unit Install according to Drawing for heat pump unit.) 6 Half union Spanner...
...indoor unit. shall not enter the pipe. 3.Connection Use the same method on terminal block and insert the plugs fully into terminal block, then tighten the screws. Loosen the screws on indoor unit. Insert the cable according to terminal number in the same manner as figure. (Note: Only for the installation of indoor and outdoor units 2.Connection of pipes To bend a pipe... not to crush the pipe Connecting the pipe of gas side first makes working easier. Outdoor unit Outdoor unit 1.Installation of Outdoor Unit Install according to Drawing for heat pump unit.) 6 Half union Spanner...
User Manual
Page 7
... per exceeding meter. Outdoor unit 5.Purging Method: Push the air out of the indoor unit and piping as followes: (1) Remove the valve cap on 2-way valve in outdoor unit. (2) Loosen by 1/2 turn the flare nut of gas pipe, which is conneted to the following list. Piping length 5m 7m Additional amount No need 40g 10m 100g Note: When extending piping, air inside piping shall be removed by using specified torque...
... per exceeding meter. Outdoor unit 5.Purging Method: Push the air out of the indoor unit and piping as followes: (1) Remove the valve cap on 2-way valve in outdoor unit. (2) Loosen by 1/2 turn the flare nut of gas pipe, which is conneted to the following list. Piping length 5m 7m Additional amount No need 40g 10m 100g Note: When extending piping, air inside piping shall be removed by using specified torque...
User Manual
Page 8
... of installing an air conditioner in a room, please apply heat insulation to operate through the instruction manual. It waves. Check Items for Test Run Put check mark in heat pump) performed normally? Is there any noise? Is the lamp normally lighting? Is the operation of pipe connecting? Less than 5cm It becomes high midway. Heat insulation of room temperature regulator normal? 8 Is power source voltage abided by the code...
... of installing an air conditioner in a room, please apply heat insulation to operate through the instruction manual. It waves. Check Items for Test Run Put check mark in heat pump) performed normally? Is there any noise? Is the lamp normally lighting? Is the operation of pipe connecting? Less than 5cm It becomes high midway. Heat insulation of room temperature regulator normal? 8 Is power source voltage abided by the code...