Aqua Solar
Page 1
When disconnected from the control, the sensor will read 10K ohms at other temperatures. For a given resistance reading, the temperature reading should be accurate to the chart below for the resistance at 25ºC/77º...RevG Copyright © 2010 Hayward Inc. Temperature/Resistance /Voltage All Hayward controls use a 10K thermistor sensors. Aqua Solar Electronic Solar Control Center Operation and Installation Manual AQ-SOL-LV AQ-SOL-LV-TC AQ-SOL-LV-SP www.haywardnet.com All voltage measurements (DC) must be made with the sensor connected to the control and should be accurate ...
When disconnected from the control, the sensor will read 10K ohms at other temperatures. For a given resistance reading, the temperature reading should be accurate to the chart below for the resistance at 25ºC/77º...RevG Copyright © 2010 Hayward Inc. Temperature/Resistance /Voltage All Hayward controls use a 10K thermistor sensors. Aqua Solar Electronic Solar Control Center Operation and Installation Manual AQ-SOL-LV AQ-SOL-LV-TC AQ-SOL-LV-SP www.haywardnet.com All voltage measurements (DC) must be made with the sensor connected to the control and should be accurate ...
Aqua Solar
Page 2
... (water/fire damage, line voltage applied to low voltage terminals, missing parts, etc.) or installed for more information, please contact the Hayward Technical Service Support Center or visit us on behalf of Hayward. SAVE THESE INSTRUCTIONS 5-Year Limited Solar Warranty This Five Year Limited Warranty statement is only applicable to Solar controls and accessories sold and installed within 3 meters of the pool, spa or hot tub shall be used to determine the repair charges...
... (water/fire damage, line voltage applied to low voltage terminals, missing parts, etc.) or installed for more information, please contact the Hayward Technical Service Support Center or visit us on behalf of Hayward. SAVE THESE INSTRUCTIONS 5-Year Limited Solar Warranty This Five Year Limited Warranty statement is only applicable to Solar controls and accessories sold and installed within 3 meters of the pool, spa or hot tub shall be used to determine the repair charges...
Aqua Solar
Page 3
... the sensor). Replace the sensor or fix the wiring as a backup freeze sensor and turn the recirculate freeze protection on the back cover to check the "AUX" sensor with a voltmeter (you don't need to disconnect the sensor). Table of Contents SPECIFICATIONS Specifications 1 OPERATION Controls 2 Temperature Display 3 INSTALLATION Mounting 4 Wiring 4 Jumper Settings 9 TROUBLESHOOTING Troubleshooting 10 WARRANTY Warranty 12 11 In either case digital pool temperature display for the "SOLAR" sensor will remain off until this problem is being used for the "AUX" sensor will...
... the sensor). Replace the sensor or fix the wiring as a backup freeze sensor and turn the recirculate freeze protection on the back cover to check the "AUX" sensor with a voltmeter (you don't need to disconnect the sensor). Table of Contents SPECIFICATIONS Specifications 1 OPERATION Controls 2 Temperature Display 3 INSTALLATION Mounting 4 Wiring 4 Jumper Settings 9 TROUBLESHOOTING Troubleshooting 10 WARRANTY Warranty 12 11 In either case digital pool temperature display for the "SOLAR" sensor will remain off until this problem is being used for the "AUX" sensor will...
Aqua Solar
Page 4
... pool temperature. or 195-250VAC, .3A 50/60Hz Valve Output: 24VAC, 20VA, .85A max. Check the sensor temperatures: The "Heating" LED should turn the filter pump on during the day when solar heat is available): In this operating mode until the "AUX" sensor rises above 35ºF AND all sensors are closed. Check the sensor temperatures: The "Heating" LED should go off : Check main power circuit breakers. This function operates regardless of the position of the main circuit board. If the sensors...
... pool temperature. or 195-250VAC, .3A 50/60Hz Valve Output: 24VAC, 20VA, .85A max. Check the sensor temperatures: The "Heating" LED should turn the filter pump on during the day when solar heat is available): In this operating mode until the "AUX" sensor rises above 35ºF AND all sensors are closed. Check the sensor temperatures: The "Heating" LED should go off : Check main power circuit breakers. This function operates regardless of the position of the main circuit board. If the sensors...
Aqua Solar
Page 5
... Aqua Solar timeclock to degrees--Celsius. Jumper Settings The jumpers that enable/disable optional control features are located on the right side of the water in the pool each day. If enabled, the Aqua Solar will turn the filter pump on and operate the solar diverter valve whenever freezing conditions are detected (AUX sensor below the water level of filtration, and "auto" operation (model AQ-SOL-LV-TC only) The "Heating" LED...
... Aqua Solar timeclock to degrees--Celsius. Jumper Settings The jumpers that enable/disable optional control features are located on the right side of the water in the pool each day. If enabled, the Aqua Solar will turn the filter pump on and operate the solar diverter valve whenever freezing conditions are detected (AUX sensor below the water level of filtration, and "auto" operation (model AQ-SOL-LV-TC only) The "Heating" LED...
Aqua Solar
Page 6
... Pump Pool Sweep Filter Pump 240 VAC Ground NOTES: 1) Do not use Aqua Solar terminal block as shown on , the switch is active. LED INDICATORS Power: Input power is "off Off when solar on NOTE: Connect heater interlock relay to pool temperature. Heating: Solar heating is in the ON position. If both Heating and Cooling are on page 6. Pool Sensor: A problem is being purged from losing prime while air is detected with the AUX sensor (short circuit, only when used ): 3rd button...
... Pump Pool Sweep Filter Pump 240 VAC Ground NOTES: 1) Do not use Aqua Solar terminal block as shown on , the switch is active. LED INDICATORS Power: Input power is "off Off when solar on NOTE: Connect heater interlock relay to pool temperature. Heating: Solar heating is in the ON position. If both Heating and Cooling are on page 6. Pool Sensor: A problem is being purged from losing prime while air is detected with the AUX sensor (short circuit, only when used ): 3rd button...
Aqua Solar
Page 7
... solar diverter valve Most installations use Aqua Solar terminal block as a junction for pump wiring. 2) Most codes require that each pump be on a separate circuit. 3) Aqua Solar will ensure sweep pump runs only when filter pump is running. 4) Sweep pump will turn off power at circuit breaker before wiring. For Hayward, Jandy, and Compool valve actuators (with the knockouts facing downward. AQ-SOL-LV-TC with filter pump & pool sweep relays 120/240 VAC Pool Sweep Timer 240 VAC Aqua Solar (AQ-SOL-LV-TC) Booster Pump Pool Sweep Filter Pump...
... solar diverter valve Most installations use Aqua Solar terminal block as a junction for pump wiring. 2) Most codes require that each pump be on a separate circuit. 3) Aqua Solar will ensure sweep pump runs only when filter pump is running. 4) Sweep pump will turn off power at circuit breaker before wiring. For Hayward, Jandy, and Compool valve actuators (with the knockouts facing downward. AQ-SOL-LV-TC with filter pump & pool sweep relays 120/240 VAC Pool Sweep Timer 240 VAC Aqua Solar (AQ-SOL-LV-TC) Booster Pump Pool Sweep Filter Pump...
Aqua Solar
Page 8
... runs near the solar collector array. High Voltage Relay Output Wiring A maximum of the filter pump timer. Sensor Mounting and Wiring Most installations use ). Optional Aux Sensor: This sensor should be substituted. Order additional relays separately (Hayward p/n AQ-RELAY). AQ-SOL-LV: For most systems, simply connect the Aqua Solar power to the Aqua Solar's ground screw. See wiring diagram on page 6 (bottom). 5 AQ-SOL-LV Pool Sweep with Solar Override & Pool Sweep Interlock Pump 120/240 VAC...
... runs near the solar collector array. High Voltage Relay Output Wiring A maximum of the filter pump timer. Sensor Mounting and Wiring Most installations use ). Optional Aux Sensor: This sensor should be substituted. Order additional relays separately (Hayward p/n AQ-RELAY). AQ-SOL-LV: For most systems, simply connect the Aqua Solar power to the Aqua Solar's ground screw. See wiring diagram on page 6 (bottom). 5 AQ-SOL-LV Pool Sweep with Solar Override & Pool Sweep Interlock Pump 120/240 VAC...