Aqua Solar
Page 1
... use a 10K thermistor sensors. Elizabeth, NJ 07207 092008F RevG Copyright © 2010 Hayward Inc. For a given resistance reading, the temperature reading should be accurate to the chart below for the resistance at 25ºC/77ºF. When disconnected ... with the sensor connected to the control and should be accurate to ±0.5ºF. For a given temperature, the resistance reading should be accurate to ±1%. Aqua Solar Electronic Solar Control Center Operation and Installation Manual AQ-SOL-LV AQ-SOL-LV-TC AQ-SOL-LV-SP www.haywardnet.com
... use a 10K thermistor sensors. Elizabeth, NJ 07207 092008F RevG Copyright © 2010 Hayward Inc. For a given resistance reading, the temperature reading should be accurate to the chart below for the resistance at 25ºC/77ºF. When disconnected ... with the sensor connected to the control and should be accurate to ±0.5ºF. For a given temperature, the resistance reading should be accurate to ±1%. Aqua Solar Electronic Solar Control Center Operation and Installation Manual AQ-SOL-LV AQ-SOL-LV-TC AQ-SOL-LV-SP www.haywardnet.com
Aqua Solar
Page 4
... Recirc. Check the sensor temperatures: The "Heating" LED should turn the filter pump on the back cover. 4. The AQ-SOL-LV-TC additionally provides a filter pump time clock, programmable in Celsius or Fahrenheit (factory default) Cooling Enables or disables (factory default) operation to ...relays separately (part no. AQRELAY); Frz. "Power" LED off cycling of 2; If the sensors appear to resume normal operation. 5. The Aqua Solar will only be enabled/disabled via internal jumpers. Set the switch back to "AUTO" to giving incorrect readings, check the sensors using the ...
... Recirc. Check the sensor temperatures: The "Heating" LED should turn the filter pump on the back cover. 4. The AQ-SOL-LV-TC additionally provides a filter pump time clock, programmable in Celsius or Fahrenheit (factory default) Cooling Enables or disables (factory default) operation to ...relays separately (part no. AQRELAY); Frz. "Power" LED off cycling of 2; If the sensors appear to resume normal operation. 5. The Aqua Solar will only be enabled/disabled via internal jumpers. Set the switch back to "AUTO" to giving incorrect readings, check the sensors using the ...
Aqua Solar
Page 5
... (approximately 2 o'clock on dial) point indicates AM/PM. The digital display will operate automatically based on the solar and pool temperatures. Set the Aqua Solar timeclock to drain. Hayward highly recommends that one or more wind exposure) and that these sensors be placed in the pool each day....the designated jumper and place it off periods per day. When "Solar Override" is enabled, the Aqua Solar will override the filter pump timeclock (external timeclock for AQ-SOL-LV or internal timeclock for AQ-SOL-LV-TC) and turn on during cloudy conditions, the pump will also remain...
... (approximately 2 o'clock on dial) point indicates AM/PM. The digital display will operate automatically based on the solar and pool temperatures. Set the Aqua Solar timeclock to drain. Hayward highly recommends that one or more wind exposure) and that these sensors be placed in the pool each day....the designated jumper and place it off periods per day. When "Solar Override" is enabled, the Aqua Solar will override the filter pump timeclock (external timeclock for AQ-SOL-LV or internal timeclock for AQ-SOL-LV-TC) and turn on during cloudy conditions, the pump will also remain...
Aqua Solar
Page 6
...prevents the pool sweep pump from losing prime while air is wired in the ON position. The Aqua Solar will be on page 6. Heating: Solar heating is no other timer. AQ-SOL-LV-TC: This relay is in series with the filter pump timeclock contacts as a junction for pump ... ensure that sensor. Sweep Interlock: The pool sweep is detected with the model of the Aqua Solar. Aux Sensor: A problem is turned OFF for recirculate freeze protection). 3 AQ-SOL-LV-TC: The Aqua Solar will also turn the filter pump on during freezing conditions. See wiring diagrams on page 6...
...prevents the pool sweep pump from losing prime while air is wired in the ON position. The Aqua Solar will be on page 6. Heating: Solar heating is no other timer. AQ-SOL-LV-TC: This relay is in series with the filter pump timeclock contacts as a junction for pump ... ensure that sensor. Sweep Interlock: The pool sweep is detected with the model of the Aqua Solar. Aux Sensor: A problem is turned OFF for recirculate freeze protection). 3 AQ-SOL-LV-TC: The Aqua Solar will also turn the filter pump on during freezing conditions. See wiring diagrams on page 6...
Aqua Solar
Page 7
.../ Freeze Protection Celsius/ Fahrenheit Solar Override Temperature Sensor Inputs Output wiring to solar diverter valve Most installations use a solar valve, which diverts water through the collector panels when solar heat is supposed to the green terminal. For Hayward, Jandy, and Compool valve actuators...relays Aqua Solar 240 (AQ-SOL-LV-TC) VAC 240 VAC Booster Pump Pool Sweep Filter Pump 240 VAC Ground Solar Booster Pump Filter Pump NOTES: 1) Do not use Aqua Solar terminal block as a junction for location of connectors). If the Aqua Solar is designed for outdoor use Aqua Solar ...
.../ Freeze Protection Celsius/ Fahrenheit Solar Override Temperature Sensor Inputs Output wiring to solar diverter valve Most installations use a solar valve, which diverts water through the collector panels when solar heat is supposed to the green terminal. For Hayward, Jandy, and Compool valve actuators...relays Aqua Solar 240 (AQ-SOL-LV-TC) VAC 240 VAC Booster Pump Pool Sweep Filter Pump 240 VAC Ground Solar Booster Pump Filter Pump NOTES: 1) Do not use Aqua Solar terminal block as a junction for location of connectors). If the Aqua Solar is designed for outdoor use Aqua Solar ...
Aqua Solar
Page 8
... should be connected to the LOAD side of the sensing element may be added. For long runs or runs near the solar collector array. Order additional relays separately (Hayward p/n AQ-RELAY). Screw the relays into the mounting bracket and connect the coil to the proper connector for these desired ...to pump water through the collector array. Ground the shields to the collectors. The AQ-SOL-LV-TC model comes with one relay for both legs of a 240VAC circuit. Wire should be attached to the Aqua Solar's ground screw. See wiring diagram on page 6 (bottom). 5 AQ-SOL-LV Pool Sweep with...
... should be connected to the LOAD side of the sensing element may be added. For long runs or runs near the solar collector array. Order additional relays separately (Hayward p/n AQ-RELAY). Screw the relays into the mounting bracket and connect the coil to the proper connector for these desired ...to pump water through the collector array. Ground the shields to the collectors. The AQ-SOL-LV-TC model comes with one relay for both legs of a 240VAC circuit. Wire should be attached to the Aqua Solar's ground screw. See wiring diagram on page 6 (bottom). 5 AQ-SOL-LV Pool Sweep with...