User Guide
Page 5
...System-board internal connectors 21 System-board external connectors 22 System-board switches and jumpers 23 System-board LEDs 25 System-board optional-device connectors 26 Installation guidelines 27 System reliability guidelines 28 Working inside the server with the power on 28 Handling static-sensitive devices 29 Removing the cover 29 Installing a memory... 55 Connecting the cables 56 Updating the server configuration 56 Chapter 3. The System x3250 M3 server 1 The IBM System x Documentation CD 3 Hardware and software requirements 3 Using the Documentation Browser ...
...System-board internal connectors 21 System-board external connectors 22 System-board switches and jumpers 23 System-board LEDs 25 System-board optional-device connectors 26 Installation guidelines 27 System reliability guidelines 28 Working inside the server with the power on 28 Handling static-sensitive devices 29 Removing the cover 29 Installing a memory... 55 Connecting the cables 56 Updating the server configuration 56 Chapter 3. The System x3250 M3 server 1 The IBM System x Documentation CD 3 Hardware and software requirements 3 Using the Documentation Browser ...
User Guide
Page 22
... not apply. Features and specifications Microprocessor: v Supports one 351-watt high efficiency power supply with five speed-controlled fans. 6 IBM System x3250 M3 Types 4251, 4252, and 4261: Installation and User's Guide Simple-swap models only support ServeRAID-BR10il adapter. Fans: The server comes standard...hard disk drives support AHCI mode. - Features and specifications The following information is shared among the cores v Support for Intel Extended Memory 64 Technology (EM64T) Note: v Use the Setup utility to determine the type and speed of the following configurations: v Four 2.5-...
... not apply. Features and specifications Microprocessor: v Supports one 351-watt high efficiency power supply with five speed-controlled fans. 6 IBM System x3250 M3 Types 4251, 4252, and 4261: Installation and User's Guide Simple-swap models only support ServeRAID-BR10il adapter. Fans: The server comes standard...hard disk drives support AHCI mode. - Features and specifications The following information is shared among the cores v Support for Intel Extended Memory 64 Technology (EM64T) Note: v Use the Setup utility to determine the type and speed of the following configurations: v Four 2.5-...
User Guide
Page 23
...v Input kilovolt-amperes (kVA), approximately: - The noise emission level stated in the declared (upper limit) sound-power level, in use. 2. The System x3250 M3 server 7 v An optional ServeRAID-MR10i SAS/SATA adapter that provides RAID levels 0, 1, 5, 6, and 10 can be ordered. altitude: 0 to ...ordered. Table 1. Video controller (integrated into IMM): v Matrox G200 v SVGA compatible video controller v Avocent Digital Video Compression v Video memory is not expandable Note: The maximum video resolution is no keyboard connector or mouse connector on page 79. Minimum: 200 V ac -...
...v Input kilovolt-amperes (kVA), approximately: - The noise emission level stated in the declared (upper limit) sound-power level, in use. 2. The System x3250 M3 server 7 v An optional ServeRAID-MR10i SAS/SATA adapter that provides RAID levels 0, 1, 5, 6, and 10 can be ordered. altitude: 0 to ...ordered. Table 1. Video controller (integrated into IMM): v Matrox G200 v SVGA compatible video controller v Avocent Digital Video Compression v Video memory is not expandable Note: The maximum video resolution is no keyboard connector or mouse connector on page 79. Minimum: 200 V ac -...
User Guide
Page 24
... interfaces: - Simple Network Management Protocol (SNMP) version 3 - Common Information Model (CIM) - v UEFI-compliant server firmware The IBM System x Server Firmware offers several features, including Unified Extensible Firmware Interface (UEFI) version 2.1 compliance, Active Energy Manager (AEM) technology, ... on the integrated USB memory. Optionally, the IMM also provides a virtual presence capability for ServeRAID controllers and service processors The diagnostic programs create a merged log that includes events from a Web browser. 8 IBM System x3250 M3 Types 4251, 4252, and 4261: ...
... interfaces: - Simple Network Management Protocol (SNMP) version 3 - Common Information Model (CIM) - v UEFI-compliant server firmware The IBM System x Server Firmware offers several features, including Unified Extensible Firmware Interface (UEFI) version 2.1 compliance, Active Energy Manager (AEM) technology, ... on the integrated USB memory. Optionally, the IMM also provides a virtual presence capability for ServeRAID controllers and service processors The diagnostic programs create a merged log that includes events from a Web browser. 8 IBM System x3250 M3 Types 4251, 4252, and 4261: ...
User Guide
Page 25
... - Uploading a diskette image to the IMM memory and mapping it to make your Intel-processor-based server powerful, scalable, and reliable. The System x3250 M3 server 9 The VMware ESXi embedded hypervisor software is provided on a host system at the same time. v IBM X-Architecture technology IBM X-Architecture technology combines proven, innovative IBM designs to the server as virtual drives...
... - Uploading a diskette image to the IMM memory and mapping it to make your Intel-processor-based server powerful, scalable, and reliable. The System x3250 M3 server 9 The VMware ESXi embedded hypervisor software is provided on a host system at the same time. v IBM X-Architecture technology IBM X-Architecture technology combines proven, innovative IBM designs to the server as virtual drives...
User Guide
Page 27
..., and serviceability (RAS). The System x3250 M3 server 11 See the operating-system documentation for ServeRAID and Ethernet adapters v ECC memory v Error codes and messages v Hot-swap hard disk drives v Integrated management module (IMM) v Menu-driven setup, system configuration, and redundant array of ... Remote system problem-determination support v Read-only memory (ROM) checksums v ROM-based diagnostics v SDRAM with which you can diagnose and correct problems. Your server has the following RAS features: v 1-year parts and 1-year labor limited warranty for machine type 4251, 3-...
..., and serviceability (RAS). The System x3250 M3 server 11 See the operating-system documentation for ServeRAID and Ethernet adapters v ECC memory v Error codes and messages v Hot-swap hard disk drives v Integrated management module (IMM) v Menu-driven setup, system configuration, and redundant array of ... Remote system problem-determination support v Read-only memory (ROM) checksums v ROM-based diagnostics v SDRAM with which you can diagnose and correct problems. Your server has the following RAS features: v 1-year parts and 1-year labor limited warranty for machine type 4251, 3-...
User Guide
Page 28
...IMM firmware, and read-only memory (ROM) resident code, locally or over the LAN v Vital product data (VPD) on microprocessor, system board, power supply, and SAS/SATA (hot-swap hard disk drive) backplane v Wake on LAN capability IBM Systems Director IBM Systems Director is focused on a ...problems v Notifying users when systems need updates and distributing and installing updates on driving these systems relate to one another, and identifying their statuses, helping to the base capabilities v Managing the life cycles of virtual resources 12 IBM System x3250 M3 Types 4251, 4252, and 4261: ...
...IMM firmware, and read-only memory (ROM) resident code, locally or over the LAN v Vital product data (VPD) on microprocessor, system board, power supply, and SAS/SATA (hot-swap hard disk drive) backplane v Wake on LAN capability IBM Systems Director IBM Systems Director is focused on a ...problems v Notifying users when systems need updates and distributing and installing updates on driving these systems relate to one another, and identifying their statuses, helping to the base capabilities v Managing the life cycles of virtual resources 12 IBM System x3250 M3 Types 4251, 4252, and 4261: ...
User Guide
Page 32
...to requests to the service processor, such as a USB mouse, keyboard, or other device to any of memory (physical or logical) is installed, some memory is reserved for system resources depends on the server Approximately 5 seconds after the server is connected to ac power, the power-... the server. You might start running to provide cooling while the server is not turned on 16 IBM System x3250 M3 Types 4251, 4252, and 4261: Installation and User's Guide however, the server can take a memory dump (use a pen or the end of these connectors to connect the server to a network....
...to requests to the service processor, such as a USB mouse, keyboard, or other device to any of memory (physical or logical) is installed, some memory is reserved for system resources depends on the server Approximately 5 seconds after the server is connected to ac power, the power-... the server. You might start running to provide cooling while the server is not turned on 16 IBM System x3250 M3 Types 4251, 4252, and 4261: Installation and User's Guide however, the server can take a memory dump (use a pen or the end of these connectors to connect the server to a network....
User Guide
Page 46
... MHz, PC3-8500 or PC3-10600 (single-rank, dual-rank, or quad-rank), registered or unbuffered, synchronous dynamic random-access memory (SDRAM) dual inline memory modules (DIMMs) with error correcting code (ECC). However, they do not have to solve the problem. 3. note of which LEDs... information that the server supports is determined by the slowest DIMM in DIMM connectors 1 and 4. 30 IBM System x3250 M3 Types 4251, 4252, and 4261: Installation and User's Guide then, see "System-board optional-device connectors" on the type of the server until the cover has disengaged from the rack...
... MHz, PC3-8500 or PC3-10600 (single-rank, dual-rank, or quad-rank), registered or unbuffered, synchronous dynamic random-access memory (SDRAM) dual inline memory modules (DIMMs) with error correcting code (ECC). However, they do not have to solve the problem. 3. note of which LEDs... information that the server supports is determined by the slowest DIMM in DIMM connectors 1 and 4. 30 IBM System x3250 M3 Types 4251, 4252, and 4261: Installation and User's Guide then, see "System-board optional-device connectors" on the type of the server until the cover has disengaged from the rack...
User Guide
Page 47
... 31 v The specifications of the DIMMs installed. The following sections provide additional information specific to unbuffered and registered DIMMs that the memory configuration has changed. The information on the label is the CAS latency, in clocks at the fastest common frequency of a DDR3... be reserved for example, 1GB, 2GB, or 4GB) e is the number of usable memory is single-rank (n=1), dual-rank (n=2), or quad-rank (n=4). 2. When you restart the server, the system displays a message that indicates that you install or remove DIMMs, the server configuration information changes...
... 31 v The specifications of the DIMMs installed. The following sections provide additional information specific to unbuffered and registered DIMMs that the memory configuration has changed. The information on the label is the CAS latency, in clocks at the fastest common frequency of a DDR3... be reserved for example, 1GB, 2GB, or 4GB) e is the number of usable memory is single-rank (n=1), dual-rank (n=2), or quad-rank (n=4). 2. When you restart the server, the system displays a message that indicates that you install or remove DIMMs, the server configuration information changes...
User Guide
Page 48
...3 connector 4 connector 5 Populated Empty Empty Empty Empty Populated Empty Empty Populated Empty Populated Populated Empty Populated Populated DIMM connector 6 Empty Empty Empty 32 IBM System x3250 M3 Types 4251, 4252, and 4261: Installation and User's Guide Table 7. v DIMM slots 3 and 6 are 1 GB, 2 GB, and 4 GB DIMMs... 4 GB 16 GB v The following table lists the maximum DIMM population using ranked UDIMMs (depending on your model) Number of memory in some server models when you install UDIMMs in each channel DIMM type 2 1 Unbuffered DDR3 ECC 2 2 Unbuffered DDR3 ECC ...
...3 connector 4 connector 5 Populated Empty Empty Empty Empty Populated Empty Empty Populated Empty Populated Populated Empty Populated Populated DIMM connector 6 Empty Empty Empty 32 IBM System x3250 M3 Types 4251, 4252, and 4261: Installation and User's Guide Table 7. v DIMM slots 3 and 6 are 1 GB, 2 GB, and 4 GB DIMMs... 4 GB 16 GB v The following table lists the maximum DIMM population using ranked UDIMMs (depending on your model) Number of memory in some server models when you install UDIMMs in each channel DIMM type 2 1 Unbuffered DDR3 ECC 2 2 Unbuffered DDR3 ECC ...
User Guide
Page 49
...system performance. Supported RDIMM population per channel DIMM connectors per DIMMs installed channel in each channel DIMM type 3 1 Registered DDR3 ECC 3 2 Registered DDR3 ECC 3 3 Registered DDR3 ECC 3 1 Registered DDR3 ECC 3 2 Registered DDR3 ECC DIMM speed 1066, 1333 1066, 1333 800 1066 800 Ranks per channel. Maximum memory...GB 6 Dual-rank RDIMMs 4 GB 24 GB 4 Quad-rank RDIMMs 8 GB 32 GB v The following table shows the RDIMM memory population rule to three single-rank, dual-rank, or quad-rank RDIMMs per DIMM (any combination) Single-rank, dual-rank Single-...
...system performance. Supported RDIMM population per channel DIMM connectors per DIMMs installed channel in each channel DIMM type 3 1 Registered DDR3 ECC 3 2 Registered DDR3 ECC 3 3 Registered DDR3 ECC 3 1 Registered DDR3 ECC 3 2 Registered DDR3 ECC DIMM speed 1066, 1333 1066, 1333 800 1066 800 Ranks per channel. Maximum memory...GB 6 Dual-rank RDIMMs 4 GB 24 GB 4 Quad-rank RDIMMs 8 GB 32 GB v The following table shows the RDIMM memory population rule to three single-rank, dual-rank, or quad-rank RDIMMs per DIMM (any combination) Single-rank, dual-rank Single-...
User Guide
Page 75
... in the Setup utility, the changes are reflected in the system summary. - This choice is on the full Setup utility menu only. - If you make changes through other choices in the Setup utility, some of installed memory. Legacy Support Select this choice to view or change the ...the microprocessor, machine type and model of the server, the serial number, the system UUID, and the amount of those changes are non-UEFI compliant. - Processors Select this choice to view or change the memory settings. - Memory Select this choice to view or change the processor settings. - enable or ...
... in the Setup utility, the changes are reflected in the system summary. - This choice is on the full Setup utility menu only. - If you make changes through other choices in the Setup utility, some of installed memory. Legacy Support Select this choice to view or change the ...the microprocessor, machine type and model of the server, the serial number, the system UUID, and the amount of those changes are non-UEFI compliant. - Processors Select this choice to view or change the memory settings. - Memory Select this choice to view or change the processor settings. - enable or ...
User Guide
Page 83
... through the IPMI 2.0 protocol. might be configured to watch for the operating system watchdog timer and reboot the system after a timeout, if the ASR feature is supported by pressing an NMI button on the system board for an operating-system memory dump. v Operating-system failure blue screen capture. The USB flash device installs in -band and...
... through the IPMI 2.0 protocol. might be configured to watch for the operating system watchdog timer and reboot the system after a timeout, if the ASR feature is supported by pressing an NMI button on the system board for an operating-system memory dump. v Operating-system failure blue screen capture. The USB flash device installs in -band and...
User Guide
Page 84
... to the IMM memory and mapping it indicates that the key might not be able to access the network remotely to mount or unmount drives or images on a remote client, and mapping ISO and diskette image files as a virtual drive 68 IBM System x3250 M3 Types 4251, 4252, and 4261...: Installation and User's Guide To recover the flash device image, complete the following functions: v Remotely viewing video with the system to recover the flash device image. For additional information and ...
... to the IMM memory and mapping it indicates that the key might not be able to access the network remotely to mount or unmount drives or images on a remote client, and mapping ISO and diskette image files as a virtual drive 68 IBM System x3250 M3 Types 4251, 4252, and 4261...: Installation and User's Guide To recover the flash device image, complete the following functions: v Remotely viewing video with the system to recover the flash device image. For additional information and ...
User Guide
Page 94
... Maximum memory might require replacement of merchantability and fitness for 1,073,741,824 bytes. UNIX is it intended to be used under license therefrom. Important notes This product is not intended to be connected directly or indirectly by third parties. 78 IBM System x3250 M3 Types 4251, 4252... drive capacities assume the replacement of any means whatsoever to the implied warranties of the standard memory with the largest currently supported drives that are available from IBM. Intel, Intel Xeon, Itanium, and Pentium are trademarks or registered trademarks of Intel Corporation ...
... Maximum memory might require replacement of merchantability and fitness for 1,073,741,824 bytes. UNIX is it intended to be used under license therefrom. Important notes This product is not intended to be connected directly or indirectly by third parties. 78 IBM System x3250 M3 Types 4251, 4252... drive capacities assume the replacement of any means whatsoever to the implied warranties of the standard memory with the largest currently supported drives that are available from IBM. Intel, Intel Xeon, Itanium, and Pentium are trademarks or registered trademarks of Intel Corporation ...
User Guide
Page 102
...54 installing 2.5-inch hot-swap hard disk drive 37 an adapter 42 an optional DVD drive 40 hypervisor flash device 54 memory modules 30 the IBM ServeRAID-MR10i controller 47 the ServeRAID-MR10is VAULT adapter 50 the virtual media key 53 installing drives 35 installing options 19...status 15 Power-error LED 15 power-on 14 power-on button 14 system locator 14 system-error 14 LEDs on the system board 25 legacy operating system requirement 65 local area network (LAN) 10 LSI Configuration program 71 M management, system 8 86 IBM System x3250 M3 Types 4251, 4252, and 4261: Installation and User's Guide
...54 installing 2.5-inch hot-swap hard disk drive 37 an adapter 42 an optional DVD drive 40 hypervisor flash device 54 memory modules 30 the IBM ServeRAID-MR10i controller 47 the ServeRAID-MR10is VAULT adapter 50 the virtual media key 53 installing drives 35 installing options 19...status 15 Power-error LED 15 power-on 14 power-on button 14 system locator 14 system-error 14 LEDs on the system board 25 legacy operating system requirement 65 local area network (LAN) 10 LSI Configuration program 71 M management, system 8 86 IBM System x3250 M3 Types 4251, 4252, and 4261: Installation and User's Guide
User Guide
Page 103
... the IP address for the IMM 69 online documentation 2 online publications 5 operating system 19 optional device connectors on the system board 26 optional optical drive specifications 6 options installing 19 order of installation memory modules 34 P particulate contamination 7, 79 password 62 administrator 62 power-on 62 ...reliability 11 remote presence feature 9 using 68 removing the cover 29 replacing a PCI riser-card assembly 41 the cover 55 the IBM ServeRAID-BR10il controller v2 45 requirements software and hardware 3 reset button 14 riser card removing 43 slots 26 S Safety Information 5 ...
... the IP address for the IMM 69 online documentation 2 online publications 5 operating system 19 optional device connectors on the system board 26 optional optical drive specifications 6 options installing 19 order of installation memory modules 34 P particulate contamination 7, 79 password 62 administrator 62 power-on 62 ...reliability 11 remote presence feature 9 using 68 removing the cover 29 replacing a PCI riser-card assembly 41 the cover 55 the IBM ServeRAID-BR10il controller v2 45 requirements software and hardware 3 reset button 14 riser card removing 43 slots 26 S Safety Information 5 ...