User Guide
Page 32
... Installations and Initial Configuration Intel® Remote Management Module 4 and Integrated BMC Web Console User Guide Note: For the next two steps see your specific Intel® Server Systems Technical Product Specification and Intel® Server Systems Service Guide for that specific system. 3. Attach the cable to the cable connector on the server board. Table 5: Intel® Pedestal Server Systems - Mount the NIC module to the RMM4 NIC connector, as specified in the chassis. Chassis mounted Intel® Dedicated Server Management NIC Connector Locations Intel® Server...
... Installations and Initial Configuration Intel® Remote Management Module 4 and Integrated BMC Web Console User Guide Note: For the next two steps see your specific Intel® Server Systems Technical Product Specification and Intel® Server Systems Service Guide for that specific system. 3. Attach the cable to the cable connector on the server board. Table 5: Intel® Pedestal Server Systems - Mount the NIC module to the RMM4 NIC connector, as specified in the chassis. Chassis mounted Intel® Dedicated Server Management NIC Connector Locations Intel® Server...
User Guide
Page 57
... horizontal menu allow you log out. Note that a remote console (KVM) window, if active, will return to configure various settings for access to the remote console and to control the power state of the server. Console Redirection. Server Power Control Virtual Front Panel (only on EPSD Platforms Based on Intel® Xeon® Processor E5-4600/2600/2400/1600/1400 Product Families) The four tabs on the left edge...
... horizontal menu allow you log out. Note that a remote console (KVM) window, if active, will return to configure various settings for access to the remote console and to control the power state of the server. Console Redirection. Server Power Control Virtual Front Panel (only on EPSD Platforms Based on Intel® Xeon® Processor E5-4600/2600/2400/1600/1400 Product Families) The four tabs on the left edge...
Software User Guide for Windows*
Page 6
... Driver to Install SCSI/RAID Driver 38 Figure 43. Select System and Security 32 Figure 32. Click Device Manager in BIOS Setup 15 Figure 2. Choose appropriate Driver for Mass Storage Device 39 Figure 46. RAID Level 0 (Stripe 17 Figure 6. Find SAS Controller under Other Devices 33 Figure 34. Press F6 to be installed 30 Figure 29. Select Operating System to Install the Device Software 35 Figure 38. Boot from Windows 2003 Installation CD/DVD-ROM 37...
... Driver to Install SCSI/RAID Driver 38 Figure 43. Select System and Security 32 Figure 32. Click Device Manager in BIOS Setup 15 Figure 2. Choose appropriate Driver for Mass Storage Device 39 Figure 46. RAID Level 0 (Stripe 17 Figure 6. Find SAS Controller under Other Devices 33 Figure 34. Press F6 to be installed 30 Figure 29. Select Operating System to Install the Device Software 35 Figure 38. Boot from Windows 2003 Installation CD/DVD-ROM 37...
Software User Guide for Windows*
Page 14
... will support the ability Hot Plug (remove and replace) disk drives on the AHCI controller whether or not I /O is being processed. Intel® RSTe User's Guide 5 Drives added beyond this limitation (up to 8 RAID volumes to the SCU controller whether or not I /O is being processed, provided that have installed Linux, Windows 7* and Windows 2008* GA and R2. 2.3.2 Common Storage Management Interface (CSMI) Intel® RSTe will support the Common Storage Management Interface (CSMI) for reporting RAID configurations...
... will support the ability Hot Plug (remove and replace) disk drives on the AHCI controller whether or not I /O is being processed. Intel® RSTe User's Guide 5 Drives added beyond this limitation (up to 8 RAID volumes to the SCU controller whether or not I /O is being processed, provided that have installed Linux, Windows 7* and Windows 2008* GA and R2. 2.3.2 Common Storage Management Interface (CSMI) Intel® RSTe will support the Common Storage Management Interface (CSMI) for reporting RAID configurations...
Technical Product Specification
Page 25
.... Alerts the Integrated BMC of the configuration error with an IPMI command. Does not disable the processor. Displays "0194: Processor family mismatch detected" message in the error manager. Halts the system. No POST error message is logged and the system goes directly to be adjusted to the Error Manager in BIOS Setup is enabled or disabled. Major: If the "POST Error Pause" option in BIOS Setup. Intel®Server Boards S2400LP TPS Product Architecture Overview...
.... Alerts the Integrated BMC of the configuration error with an IPMI command. Does not disable the processor. Displays "0194: Processor family mismatch detected" message in the error manager. Halts the system. No POST error message is logged and the system goes directly to be adjusted to the Error Manager in BIOS Setup is enabled or disabled. Major: If the "POST Error Pause" option in BIOS Setup. Intel®Server Boards S2400LP TPS Product Architecture Overview...
Technical Product Specification
Page 32
... sizes of installed DDR3 DIMMs in the system. The BIOS displays the "Effective Memory" of the system in the BIOS setup. DIMM timings do not have no matching requirements. The term Effective Memory refers to the total size of all DIMMs populated (that is, DIMMs with regards to size and organization. Product Architecture Overview Intel®Server Boards S2400LP TPS The following memory RAS modes: Independent...
... sizes of installed DDR3 DIMMs in the system. The BIOS displays the "Effective Memory" of the system in the BIOS setup. DIMM timings do not have no matching requirements. The term Effective Memory refers to the total size of all DIMMs populated (that is, DIMMs with regards to size and organization. Product Architecture Overview Intel®Server Boards S2400LP TPS The following memory RAS modes: Independent...
Technical Product Specification
Page 38
... to Serial ATA 1.0 Specification, Revision 1.0 (AHCI support is only enabled with one of an Intel® RAID C600 Storage Upgrade Key option supporting 8 SAS/SATA ports. The implementation is capable of supporting additional chipset embedded SAS and RAID options from the SCU controller when configured with addition of several available Intel® RAID C600 Storage Upgrade Keys. Intel® Server Board S2400LP SATA/SAS port Port# 0 0 1 SCU0 2 3 Speed 6Gb/s SATA Connector On Server board 3Gb/s SATA(AHCI only); 3Gb/s SATA/SAS(non-AHCI) Bridge Board Slot There are user accessible...
... to Serial ATA 1.0 Specification, Revision 1.0 (AHCI support is only enabled with one of an Intel® RAID C600 Storage Upgrade Key option supporting 8 SAS/SATA ports. The implementation is capable of supporting additional chipset embedded SAS and RAID options from the SCU controller when configured with addition of several available Intel® RAID C600 Storage Upgrade Keys. Intel® Server Board S2400LP SATA/SAS port Port# 0 0 1 SCU0 2 3 Speed 6Gb/s SATA Connector On Server board 3Gb/s SATA(AHCI only); 3Gb/s SATA/SAS(non-AHCI) Bridge Board Slot There are user accessible...
Technical Product Specification
Page 64
... AC power loss or BMC reset. 4.12.2.2 Network Port Usage The KVM and media redirection features use by the operating System or any other application it will appear as floppy disks over all on a bare metal server (no OS present) using the remotely mounted device. CD Redirection 5123 - Note: When trying to attach a local floppy or local USB key drive, If it is in use the...
... AC power loss or BMC reset. 4.12.2.2 Network Port Usage The KVM and media redirection features use by the operating System or any other application it will appear as floppy disks over all on a bare metal server (no OS present) using the remotely mounted device. CD Redirection 5123 - Note: When trying to attach a local floppy or local USB key drive, If it is in use the...
Technical Product Specification
Page 72
... having set , a password can be cleared by changing it suppresses the USB Reordering that at least an Administrator Password be cleared by using the Password Clear jumper if necessary. This feature makes it is a hardware-based security device that addresses the growing concern on booting the system. In addition, on the next successful reboot, the Error Manager displays a Major Error code 0048, which also logs a SEL event to viewing only when a User password is required. Entering the User password...
... having set , a password can be cleared by changing it suppresses the USB Reordering that at least an Administrator Password be cleared by using the Password Clear jumper if necessary. This feature makes it is a hardware-based security device that addresses the growing concern on booting the system. In addition, on the next successful reboot, the Error Manager displays a Major Error code 0048, which also logs a SEL event to viewing only when a User password is required. Entering the User password...
Technical Product Specification
Page 75
... Quiet Boot is disabled in the system configuration, the POST Diagnostic Screen is installed in devices, the boot manager, and error manager. Revision 1.0 61 Intel order number G52803-001 When an Administrator password is displayed with a summary of the desired boot device. If the logo displays during POST. The BBS Pop-up menu using the key. Intel®Server Boards S2400LP TPS BIOS Setup Interface HotKey Combination Function Enter Setup Pop up menu that allows the user to configure the system and view current settings...
... Quiet Boot is disabled in the system configuration, the POST Diagnostic Screen is installed in devices, the boot manager, and error manager. Revision 1.0 61 Intel order number G52803-001 When an Administrator password is displayed with a summary of the desired boot device. If the logo displays during POST. The BBS Pop-up menu using the key. Intel®Server Boards S2400LP TPS BIOS Setup Interface HotKey Combination Function Enter Setup Pop up menu that allows the user to configure the system and view current settings...
Technical Product Specification
Page 82
Displays the Platform ID: S2400LP Information only. Setup Utility - With no passwords set, Administrator is entered, unless an error has occurred. Displays the current BIOS version. xx = major release version yy = minor release version zzzz = release number Information only. Intel order number G52803-001 Revision 1.0 Main Advanced Security Server Management Boot Options Logged in as: Platform ID System BIOS BIOS Version Build Date Memory Total Memory Quiet Boot POST Error Pause System Date System Time Administrator/User Enabled/Disabled Enabled/Disabled [Day MM...
Displays the Platform ID: S2400LP Information only. Setup Utility - With no passwords set, Administrator is entered, unless an error has occurred. Displays the current BIOS version. xx = major release version yy = minor release version zzzz = release number Information only. Intel order number G52803-001 Revision 1.0 Main Advanced Security Server Management Boot Options Logged in as: Platform ID System BIOS BIOS Version Build Date Memory Total Memory Quiet Boot POST Error Pause System Date System Time Administrator/User Enabled/Disabled Enabled/Disabled [Day MM...
Technical Product Specification
Page 90
... Profiles BIOS Features CPU Power and Performance Policy Intel® QPI Frequency Select Intel® Turbo Boost Technology Available Settings Performance Balanced Balanced Power Performance Setup: Advanced > Power and Performance Performance Performance (Balanced Balanced /Balanced Performance) Power Performance /Balanced Power /Power Setup: Advanced > Processor Configuration Auto Max (Auto Max) (Auto Max) (Auto Max) /6.4 GT/s /7.2 GT/s /8.0 GT/s Enabled/Disabled (Enabled) (Enabled) (Enabled) Power Power 6.4 GT/s (Enabled) 76 Revision 1.0 Intel order number...
... Profiles BIOS Features CPU Power and Performance Policy Intel® QPI Frequency Select Intel® Turbo Boost Technology Available Settings Performance Balanced Balanced Power Performance Setup: Advanced > Power and Performance Performance Performance (Balanced Balanced /Balanced Performance) Power Performance /Balanced Power /Power Setup: Advanced > Processor Configuration Auto Max (Auto Max) (Auto Max) (Auto Max) /6.4 GT/s /7.2 GT/s /8.0 GT/s Enabled/Disabled (Enabled) (Enabled) (Enabled) Power Power 6.4 GT/s (Enabled) 76 Revision 1.0 Intel order number...
Technical Product Specification
Page 98
... Legacy video device can be connected through either socket, but there is enabled for an OS without PAE support. If enabled. Enable or disable memory mapped I/O of PCI/PCIe Memory Address Space and PCIe Extended Configuration Space. both the onboard video controller and an add-in the 32-bit (4GB) address space, by limiting the amount of 64bit PCI devices to Processor Socket 1 or 2. Warning: System video is completely disabled if this options is the default. BIOS Setup Interface Intel®Server Boards S2400LP...
... Legacy video device can be connected through either socket, but there is enabled for an OS without PAE support. If enabled. Enable or disable memory mapped I/O of PCI/PCIe Memory Address Space and PCIe Extended Configuration Space. both the onboard video controller and an add-in the 32-bit (4GB) address space, by limiting the amount of 64bit PCI devices to Processor Socket 1 or 2. Warning: System video is completely disabled if this options is the default. BIOS Setup Interface Intel®Server Boards S2400LP...
Technical Product Specification
Page 99
...Port2 PXE IOM1 Port3 PXE IOM1 Port4 PXE IOM1 Port1 MAC Address IOM1 Port2 MAC Address IOM1 Port3 MAC Address IOM1 Port4 MAC Address IO Module 1 Type IOM1 InfiniBand Option ROM Enabled / Disabled Enabled / Disabled Enabled / Disabled Enabled / Disabled Enabled / Disabled Enabled / Disabled Enabled / Disabled Enabled / Disabled Enabled / Disabled Enabled / Disabled Enabled / Disabled Revision 1.0 85 Intel order number G52803-001 Advanced NIC Configuration Error! Reference source not found. Intel®Server Boards S2400LP TPS BIOS Setup Interface Setup Item NIC Configuration...
...Port2 PXE IOM1 Port3 PXE IOM1 Port4 PXE IOM1 Port1 MAC Address IOM1 Port2 MAC Address IOM1 Port3 MAC Address IOM1 Port4 MAC Address IO Module 1 Type IOM1 InfiniBand Option ROM Enabled / Disabled Enabled / Disabled Enabled / Disabled Enabled / Disabled Enabled / Disabled Enabled / Disabled Enabled / Disabled Enabled / Disabled Enabled / Disabled Enabled / Disabled Enabled / Disabled Revision 1.0 85 Intel order number G52803-001 Advanced NIC Configuration Error! Reference source not found. Intel®Server Boards S2400LP TPS BIOS Setup Interface Setup Item NIC Configuration...
Technical Product Specification
Page 112
... Intel®Server Boards S2400LP TPS Table 39. User password is required in BIOS Setup Utility. Note: Removing the administrator password also automatically removes the user password. If enabled, password entry is used to control entry access to the setup items. When Power On Password security is used . Available only if the administrator password is removed, that will also disable this option. If this option will ask for a password before continuing POST and booting. Security Configuration Screen Fields Setup Item Options Administrator Installed Password Status...
... Intel®Server Boards S2400LP TPS Table 39. User password is required in BIOS Setup Utility. Note: Removing the administrator password also automatically removes the user password. If enabled, password entry is used to control entry access to the setup items. When Power On Password security is used . Available only if the administrator password is removed, that will also disable this option. If this option will ask for a password before continuing POST and booting. Security Configuration Screen Fields Setup Item Options Administrator Installed Password Status...
Technical Product Specification
Page 117
... Serial Number and then use Backspace to delete existing value. Information only. Server Management System Information Fields Setup Item Board Part Number Board Serial Number System Part Number System Serial Number Chassis Part Number Chassis Serial Number Asset Tag BMC Firmware Revision HSC Firmware Revision ME Firmware Revision SDR Revision Help Text Press to edit system Serial Number and then use Backspace to the Server Management screen, then select the desired screen. Setup Utility - Information only. Intel®Server Boards S2400LP TPS BIOS Setup Interface To access...
... Serial Number and then use Backspace to delete existing value. Information only. Server Management System Information Fields Setup Item Board Part Number Board Serial Number System Part Number System Serial Number Chassis Part Number Chassis Serial Number Asset Tag BMC Firmware Revision HSC Firmware Revision ME Firmware Revision SDR Revision Help Text Press to edit system Serial Number and then use Backspace to the Server Management screen, then select the desired screen. Setup Utility - Information only. Intel®Server Boards S2400LP TPS BIOS Setup Interface To access...
Technical Product Specification
Page 122
... Revision 1.0 Intel order number G52803-001 BIOS Setup Interface Intel®Server Boards S2400LP TPS Setup Item Boot Timeout Options 0 - 65535 Boot Option #x Hard Disk Order Available boot devices. Network Device Order Delete Boot Option EFI Optimized Boot Enabled Disabled Boot Option Retry USB Boot Priority Enabled Disabled Enabled Disabled Static Boot Ordering Enabled Disabled Reset Static Boot Yes Order Help Text The number of seconds the BIOS should pause at the bottom of the legacy devices in this group. Set the order of the respective list [Disabled] - Set the...
... Revision 1.0 Intel order number G52803-001 BIOS Setup Interface Intel®Server Boards S2400LP TPS Setup Item Boot Timeout Options 0 - 65535 Boot Option #x Hard Disk Order Available boot devices. Network Device Order Delete Boot Option EFI Optimized Boot Enabled Disabled Boot Option Retry USB Boot Priority Enabled Disabled Enabled Disabled Static Boot Ordering Enabled Disabled Reset Static Boot Yes Order Help Text The number of seconds the BIOS should pause at the bottom of the legacy devices in this group. Set the order of the respective list [Disabled] - Set the...
Technical Product Specification
Page 155
... proceed to the BIOS Setup utility to reset the desired settings. Normal BMC functionality is powered off. This server board supports The Intel® Xeon® Processor E5-2400 product family with a Thermal Design Power (TDP) of DDR3 DIMMs installed should only be removed. AXXRMM, AXXRMM2, AXXRMM3). Clear the CMOS with any previous versions of amber POST codes during POST, the LEDs display the last POST event run with the BMC Force Update jumper set in DIMM sockets A1 and...
... proceed to the BIOS Setup utility to reset the desired settings. Normal BMC functionality is powered off. This server board supports The Intel® Xeon® Processor E5-2400 product family with a Thermal Design Power (TDP) of DDR3 DIMMs installed should only be removed. AXXRMM, AXXRMM2, AXXRMM3). Clear the CMOS with any previous versions of amber POST codes during POST, the LEDs display the last POST event run with the BMC Force Update jumper set in DIMM sockets A1 and...
Technical Product Specification
Page 91
... voltage error. Serial port component was not detected. LPC component encountered a resource conflict error. PCI component encountered a read error. Prior to system video initialization, the BIOS uses these beep codes to shadow a legacy option ROM. USB Device Beeps When POST Revision 1.0 81 Intel order number: G59328-001 LPC component encountered a controller error. PEI module component encountered an illegal software state error. ATA/ATPI ATA bus SMART not supported. Processor component encountered a mismatch error. POST Error Beep Codes Beeps Error Message 3 Memory error POST...
... voltage error. Serial port component was not detected. LPC component encountered a resource conflict error. PCI component encountered a read error. Prior to system video initialization, the BIOS uses these beep codes to shadow a legacy option ROM. USB Device Beeps When POST Revision 1.0 81 Intel order number: G59328-001 LPC component encountered a controller error. PEI module component encountered an illegal software state error. ATA/ATPI ATA bus SMART not supported. Processor component encountered a mismatch error. POST Error Beep Codes Beeps Error Message 3 Memory error POST...
Specification update
Page 10
... reset Problem The BMC may see a system halt with no Intel® C600 RAID upgrade key (any of RKSAS4, RKSAS4R5, RKSAS8, RKSAS8R5) is selcted, system may halt under Pass-through mode of SCU controller Problem Microsoft Windows Server 2003* x86 installations on mentined BIOS configuration. Implication User may see system hang with SAS drivers used , the system may halt at the boot stage. None. 8. Monthly Specification Update Enterprise Platforms and Services Marketing Problem Implication Status...
... reset Problem The BMC may see a system halt with no Intel® C600 RAID upgrade key (any of RKSAS4, RKSAS4R5, RKSAS8, RKSAS8R5) is selcted, system may halt under Pass-through mode of SCU controller Problem Microsoft Windows Server 2003* x86 installations on mentined BIOS configuration. Implication User may see system hang with SAS drivers used , the system may halt at the boot stage. None. 8. Monthly Specification Update Enterprise Platforms and Services Marketing Problem Implication Status...