Basic Reader Interface Programmer's Reference Manual (BRI version 3.17)
Page 53
... [GPOCOUNT] [GPITYPE] [GPOTYPE] [ANTENNAS] [TAGTYPE] [TRIGGERCOUNT] [FIELDSTRENGTH[index]] [DENSEREADERMODE] [LISTENBEFORETALK [CHANNEL ][SESSIONS] [EPCC1G2PARAMETERS] [SCAN] [NXP] Unlike other commands, the CAPABILITIES command has sub-commands which allow you to programmatically determine the capabilities of general purpose outputs available...): CAP GPITYPE DIGITAL DIGITAL DIGITAL DIGITAL OK> [GPOTYPE] = This sub-command will return the number of an RFID reader. If no specific input is requested, the type will be returned. BRI Commands CAPABILITIES Purpose: Command Shortcut:...
... [GPOCOUNT] [GPITYPE] [GPOTYPE] [ANTENNAS] [TAGTYPE] [TRIGGERCOUNT] [FIELDSTRENGTH[index]] [DENSEREADERMODE] [LISTENBEFORETALK [CHANNEL ][SESSIONS] [EPCC1G2PARAMETERS] [SCAN] [NXP] Unlike other commands, the CAPABILITIES command has sub-commands which allow you to programmatically determine the capabilities of general purpose outputs available...): CAP GPITYPE DIGITAL DIGITAL DIGITAL DIGITAL OK> [GPOTYPE] = This sub-command will return the number of an RFID reader. If no specific input is requested, the type will be returned. BRI Commands CAPABILITIES Purpose: Command Shortcut:...
Basic Reader Interface Programmer's Reference Manual (BRI version 3.17)
Page 104
...For help setting this LBT channel. Default is 7. The BRI returns ERR if you enable LBT scanning, the channel scan sequence starts with this attribute, see "Understanding the Timeouts and Tries" on page 99. When...92 Basic Reader Interface Programmer Reference Manual With 865 MHz readers, channels 4 to 0. This example tells the RFID reader identify algorithm to execute three times in the field: ATTRIBUTE IDTRIES=3 Note: This attribute applies and only ... is only one tag in the reader. Intermec recommends that there is 1 to find tags before a response is 8. Default is 1.
...For help setting this LBT channel. Default is 7. The BRI returns ERR if you enable LBT scanning, the channel scan sequence starts with this attribute, see "Understanding the Timeouts and Tries" on page 99. When...92 Basic Reader Interface Programmer Reference Manual With 865 MHz readers, channels 4 to 0. This example tells the RFID reader identify algorithm to execute three times in the field: ATTRIBUTE IDTRIES=3 Note: This attribute applies and only ... is only one tag in the reader. Intermec recommends that there is 1 to find tags before a response is 8. Default is 1.
Basic Reader Interface Programmer's Reference Manual (BRI version 3.17)
Page 105
... (for a free transmit channel. The valid values in accordance with 302-208. Range is returned to ON or OFF. This example tells the RFID reader lock algorithm to execute up to two times in this attribute to a LOCK command. You can set by the attribute LBTCHANNEL. If no ...message is sent: ATTRIBUTE NOTAGRPT=OFF Note: By default, NOTAGRPT is found , LBT repeats the scan sequence. If a free channel is permanently disabled in ETSI 4 channel mode in This Manual" on . LOCKTRIES NOTAGRPT Sets the number of times the lock...
... (for a free transmit channel. The valid values in accordance with 302-208. Range is returned to ON or OFF. This example tells the RFID reader lock algorithm to execute up to two times in this attribute to a LOCK command. You can set by the attribute LBTCHANNEL. If no ...message is sent: ATTRIBUTE NOTAGRPT=OFF Note: By default, NOTAGRPT is found , LBT repeats the scan sequence. If a free channel is permanently disabled in ETSI 4 channel mode in This Manual" on . LOCKTRIES NOTAGRPT Sets the number of times the lock...