Owners Manual
Page 1
INVACARE CHECK O PLUS HAND-HELD ANALYZER 2 ANALIZADOR DE OXIGENO PORTALBE INVACARE CHECK O2 ANALYSEUR D' O PORTABLE INVACARE 2 Assembly, Installation and Operating Instructions - ENGLISH Instrucciones de Ensamble, Instalación y Operación - FRENCH CANADIAN USER: BEFORE USING THIS ANALYZER, READ THIS MANUAL AND SAVE FOR FUTURE REFERENCE. DOMESTIC SPANISH Instructions pour l'assemblage, l'installation et l'utilisation -
INVACARE CHECK O PLUS HAND-HELD ANALYZER 2 ANALIZADOR DE OXIGENO PORTALBE INVACARE CHECK O2 ANALYSEUR D' O PORTABLE INVACARE 2 Assembly, Installation and Operating Instructions - ENGLISH Instrucciones de Ensamble, Instalación y Operación - FRENCH CANADIAN USER: BEFORE USING THIS ANALYZER, READ THIS MANUAL AND SAVE FOR FUTURE REFERENCE. DOMESTIC SPANISH Instructions pour l'assemblage, l'installation et l'utilisation -
Owners Manual
Page 2
...per minute O2 Oxygen concentration Percentage oxygen PSI Pressure Pounds per square inch HPA Pressure KiloPascals NOTE: The Invacare Check O2 Plus Hand-Held Analyzer can cause erroneous readings and internal damage. Pressure Inlet Flow/ Concentration Inlet LCD Display Function Button On ...unhumidified output gas of an oxygen concentrator ONLY. Oxygen rapidly accelerates combustion: DO NOT smoke while using the Invacare Check O2 Plus Hand-Held Analyzer to internal components. NOTE: The concentrator output gas, measured from the concentrator outlet fitting or from its ...
...per minute O2 Oxygen concentration Percentage oxygen PSI Pressure Pounds per square inch HPA Pressure KiloPascals NOTE: The Invacare Check O2 Plus Hand-Held Analyzer can cause erroneous readings and internal damage. Pressure Inlet Flow/ Concentration Inlet LCD Display Function Button On ...unhumidified output gas of an oxygen concentrator ONLY. Oxygen rapidly accelerates combustion: DO NOT smoke while using the Invacare Check O2 Plus Hand-Held Analyzer to internal components. NOTE: The concentrator output gas, measured from the concentrator outlet fitting or from its ...
Owners Manual
Page 3
...°C Humidity range: Altitude (maximum): 20 to 60% relative humidity Up to operate with known good battery, contact Invacare Technical Service for repair. 3. PRODUCT SPECIFICATIONS OPERATIONAL Pressure: Range: Resolution: Accuracy: 0 to 10PSIG 0 to 6.0 L/...analyzer over and press the ON button. If the unit fails to the top and take the bottom cover off . Flow: Range: Input: Resolution: Accuracy: 0 to 68.9 kPa 0.1 PSI 0.7 kPa + 2% F.S. + 2% F.S. With "O2" readings, values below 70% will be replaced whenever the BAt display is missing or displayed intermittently, contact Invacare...
...°C Humidity range: Altitude (maximum): 20 to 60% relative humidity Up to operate with known good battery, contact Invacare Technical Service for repair. 3. PRODUCT SPECIFICATIONS OPERATIONAL Pressure: Range: Resolution: Accuracy: 0 to 10PSIG 0 to 6.0 L/...analyzer over and press the ON button. If the unit fails to the top and take the bottom cover off . Flow: Range: Input: Resolution: Accuracy: 0 to 68.9 kPa 0.1 PSI 0.7 kPa + 2% F.S. + 2% F.S. With "O2" readings, values below 70% will be replaced whenever the BAt display is missing or displayed intermittently, contact Invacare...