Owners Manual
Page 2
... burn with /SensO2® Model IRC5LXO2AW Invacare 5 Model IRC5LXAW Invacare 5 con/SensO2® Modelo IRC5LXO2AW Invacare 5 Modelo IRC5LXAW IMnovadcèalereIR5Cav5ecL/SXeOns2OA²W ® Invacare 5 Modèle IRC5LXAW MInovadceallrIeR5Cm5itL/SXeOns2OA2®W IMnvoadcealroeIR5 Cco5n/LSXenOsO2A2®W Invacare 5 Modell IRC5LXAW Invacare 5 Modelo IRC5LXAW SPECIAL NOTES WARNING/CAUTION notices used in this manual apply to observe this device. SAVE THESE INSTRUCTIONS DANGER Users MUST NOT SMOKE while...
... burn with /SensO2® Model IRC5LXO2AW Invacare 5 Model IRC5LXAW Invacare 5 con/SensO2® Modelo IRC5LXO2AW Invacare 5 Modelo IRC5LXAW IMnovadcèalereIR5Cav5ecL/SXeOns2OA²W ® Invacare 5 Modèle IRC5LXAW MInovadceallrIeR5Cm5itL/SXeOns2OA2®W IMnvoadcealroeIR5 Cco5n/LSXenOsO2A2®W Invacare 5 Modell IRC5LXAW Invacare 5 Modelo IRC5LXAW SPECIAL NOTES WARNING/CAUTION notices used in this manual apply to observe this device. SAVE THESE INSTRUCTIONS DANGER Users MUST NOT SMOKE while...
Owners Manual
Page 3
TABLE OF CONTENTS CONCENTRATOR TABLE OF CONTENTS SPECIAL NOTES 2 SAFETY SUMMARY 5 FEATURES 8 SPECIFICATIONS 9 HANDLING 12 Unpacking ...12 Inspection ...12 Storage ...12 INTRODUCTION 13 OPERATING INSTRUCTIONS 13 Select a Location 13 Recommended End-User Guidelines for Optimum Performance 13 Plug in Power Cord 14 Connect Humidifier (if so prescribed 14 Power Switch 16 ... (if the unit does not feature the O2 Sensor 18 CONCENTRATOR MAINTENANCE 19 Cleaning the Cabinet Filters 19 Cabinet ...20 Humidifier ...20 TROUBLESHOOTING GUIDE 20 PREVENTIVE MAINTENANCE RECORD 22 WARRANTY 23 3
TABLE OF CONTENTS CONCENTRATOR TABLE OF CONTENTS SPECIAL NOTES 2 SAFETY SUMMARY 5 FEATURES 8 SPECIFICATIONS 9 HANDLING 12 Unpacking ...12 Inspection ...12 Storage ...12 INTRODUCTION 13 OPERATING INSTRUCTIONS 13 Select a Location 13 Recommended End-User Guidelines for Optimum Performance 13 Plug in Power Cord 14 Connect Humidifier (if so prescribed 14 Power Switch 16 ... (if the unit does not feature the O2 Sensor 18 CONCENTRATOR MAINTENANCE 19 Cleaning the Cabinet Filters 19 Cabinet ...20 Humidifier ...20 TROUBLESHOOTING GUIDE 20 PREVENTIVE MAINTENANCE RECORD 22 WARRANTY 23 3
Owners Manual
Page 5
...use of oxygen therapy requires that all other oxygen equipment. DO NOT disassemble. NO SMOKING signs should be taken to qualified service personnel. Do not move or relocate concentrator by Invacare. Refer servicing...of electric shock. For safety concerns, it is being used. Keep the openings free from HEATED or HOT surfaces.... or dropped into any object into water, call Qualified Service Personnel for a minimum of fire. READ THE FOLLOWING INFORMATION...or couch, where the air opening . For optimum performance, Invacare recommends that will not, are easily ignited and burn rapidly...
...use of oxygen therapy requires that all other oxygen equipment. DO NOT disassemble. NO SMOKING signs should be taken to qualified service personnel. Do not move or relocate concentrator by Invacare. Refer servicing...of electric shock. For safety concerns, it is being used. Keep the openings free from HEATED or HOT surfaces.... or dropped into any object into water, call Qualified Service Personnel for a minimum of fire. READ THE FOLLOWING INFORMATION...or couch, where the air opening . For optimum performance, Invacare recommends that will not, are easily ignited and burn rapidly...
Owners Manual
Page 7
...used only in accordance with the prescription of oxygen, the supplier and/or physician should be made to set the flow above RED ring. If at any spark near children or physically-challenged individuals. No adjustments should be contacted immediately. Invacare recommends that the patient is not considered life supporting...supervision is to be hazardous. Use this manual. DO NOT use as an oxygen supplement and is receiving an insufficient amount of a physician and this Owners Manual. This includes sparks from static electricity created by Invacare. An oxygen flow greater than ...
...used only in accordance with the prescription of oxygen, the supplier and/or physician should be made to set the flow above RED ring. If at any spark near children or physically-challenged individuals. No adjustments should be contacted immediately. Invacare recommends that the patient is not considered life supporting...supervision is to be hazardous. Use this manual. DO NOT use as an oxygen supplement and is receiving an insufficient amount of a physician and this Owners Manual. This includes sparks from static electricity created by Invacare. An oxygen flow greater than ...
Owners Manual
Page 8
.... FEATURES Oxygen Outlet Flowmeter FEATURES FRONT VIEW Oxygen Purity Indicator Lights (SensO2 model only) (Contact Invacare for availability in use, the plug provided with the HomeFill home oxygen compressor. Power Cord Outlet Fitting NOTE: This outlet fitting is to the HomeFill owner's manual, for available accessory information. The outlet fitting does not affect concentrator performance...
.... FEATURES Oxygen Outlet Flowmeter FEATURES FRONT VIEW Oxygen Purity Indicator Lights (SensO2 model only) (Contact Invacare for availability in use, the plug provided with the HomeFill home oxygen compressor. Power Cord Outlet Fitting NOTE: This outlet fitting is to the HomeFill owner's manual, for available accessory information. The outlet fitting does not affect concentrator performance...
Owners Manual
Page 9
ALL 5LXA/5LXO2A MODELS 93% minimum at 1 to 3 L/min 91% minimum at 4 L/min 87% minimum at 5 L/min (maximum recommended flow) *...Alarm Sieve-GARDTM Below 73% Compressor Shutdown 73% to 1828 m(6,000 ft) above sea level without degradation of concentration levels. SPECIFICATIONS SPECIFICATIONS Alternating Current Type BF Equipment Running NOT Running Attention-Consider Accompanying Documents DO NOT Smoke Class II Electrical Requirements: Rated Current Input...50 Hz 2.0 A 44 dB Average Up to 85% YELLOW O2 SYSTEM OKAY Over 85% GREEN 9 NOT RECOMMENDED FOR USE ABOVE 1828 M (6000 FT).
ALL 5LXA/5LXO2A MODELS 93% minimum at 1 to 3 L/min 91% minimum at 4 L/min 87% minimum at 5 L/min (maximum recommended flow) *...Alarm Sieve-GARDTM Below 73% Compressor Shutdown 73% to 1828 m(6,000 ft) above sea level without degradation of concentration levels. SPECIFICATIONS SPECIFICATIONS Alternating Current Type BF Equipment Running NOT Running Attention-Consider Accompanying Documents DO NOT Smoke Class II Electrical Requirements: Rated Current Input...50 Hz 2.0 A 44 dB Average Up to 85% YELLOW O2 SYSTEM OKAY Over 85% GREEN 9 NOT RECOMMENDED FOR USE ABOVE 1828 M (6000 FT).
Owners Manual
Page 10
...177; 3.5 psi) 0.7 L/min. High Pressure Alarm w/compressor shutdown. Low Pressure Alarm w/compressor shutdown. Sen2 Oxygen System (SensO2 Model) Low Flow Alarm. 46.7 cm ± 1 cm (18 3/8" ± 3/8") 67.0 cm ± 1 cm (26... lbs. ± 1 lb) 26.3 kg ± 0.5 kg (58 lbs. ± 1 lb) 10 SPECIFICATIONS SPECIFICATIONS (CONTINUED) 5LX INDICATORS: Label Symbol Status Indicator Lights (LED) I/O SYSTEM OKAY SYSTEM FAILURE GREEN RED Flow Range: ... 5 L/min. High temperature compressor shutdown. Battery Free Power Loss Alarm. Current overload or line surge shutdown. Flowrates less than 1 L/...
...177; 3.5 psi) 0.7 L/min. High Pressure Alarm w/compressor shutdown. Low Pressure Alarm w/compressor shutdown. Sen2 Oxygen System (SensO2 Model) Low Flow Alarm. 46.7 cm ± 1 cm (18 3/8" ± 3/8") 67.0 cm ± 1 cm (26... lbs. ± 1 lb) 26.3 kg ± 0.5 kg (58 lbs. ± 1 lb) 10 SPECIFICATIONS SPECIFICATIONS (CONTINUED) 5LX INDICATORS: Label Symbol Status Indicator Lights (LED) I/O SYSTEM OKAY SYSTEM FAILURE GREEN RED Flow Range: ... 5 L/min. High temperature compressor shutdown. Battery Free Power Loss Alarm. Current overload or line surge shutdown. Flowrates less than 1 L/...
Owners Manual
Page 11
SPECIFICATIONS SPECIFICATIONS (CONTINUED) Operating Ambient: Temperature: Exhaust: Oxygen Output: Cabinet: Regulatory Listing: Electrical: Placement: Tubing: Relative Humidity: Time of Operation: Recommended Storage and Shipping Temperature: 10°C -... at 15-95% relative humidity 11 Crush-Proof Tubing - 2.1 m (7 ft) cannula with : EN 55011 EN 61000-3-2 EN 61000-3-3 IEC 60601-1, AI, A2 IEC 60601-1-2 5LXO2A Model only ISO 8359 MDD No extension cords. No closer than Ambient + 19°C (+ 35°F). Less than Ambient + 2°C (+ 4°F). Impact resistant flame-retardant plastic...
SPECIFICATIONS SPECIFICATIONS (CONTINUED) Operating Ambient: Temperature: Exhaust: Oxygen Output: Cabinet: Regulatory Listing: Electrical: Placement: Tubing: Relative Humidity: Time of Operation: Recommended Storage and Shipping Temperature: 10°C -... at 15-95% relative humidity 11 Crush-Proof Tubing - 2.1 m (7 ft) cannula with : EN 55011 EN 61000-3-2 EN 61000-3-3 IEC 60601-1, AI, A2 IEC 60601-1-2 5LXO2A Model only ISO 8359 MDD No extension cords. No closer than Ambient + 19°C (+ 35°F). Less than Ambient + 2°C (+ 4°F). Impact resistant flame-retardant plastic...
Owners Manual
Page 13
... Flowrates less than those described may select a room in your house where using your oxygen concentrator. This owner's manual will tell you use your concentrator and will perform best when operated under the following conditions. Your...problems regarding your oxygen concentrator would be easily rolled from room air. Clinical studies have documented that separates oxygen from room to 5 L/min. OPERATING INSTRUCTIONS SELECT A LOCATION You may result in a well ventilated area to use your concentrator. No confined spaces (Example: NO closets). RECOMMENDED END-USER...
... Flowrates less than those described may select a room in your house where using your oxygen concentrator. This owner's manual will tell you use your concentrator and will perform best when operated under the following conditions. Your...problems regarding your oxygen concentrator would be easily rolled from room air. Clinical studies have documented that separates oxygen from room to 5 L/min. OPERATING INSTRUCTIONS SELECT A LOCATION You may result in a well ventilated area to use your concentrator. No confined spaces (Example: NO closets). RECOMMENDED END-USER...
Owners Manual
Page 14
...IF SO PRESCRIBED) 1. Place the humidifier in power cord to an electrical outlet. Fill humidifier with distilled water to assure sufficient air flow. OPERATING INSTRUCTIONS NOTE: Ensure that your concentrator is at least 7.5 cm (3 in) away from the humidifier bottle WILL travel through the cannula back to the ...patient. Water from walls, draperies or furniture to the level indicated by the manufacturer. (Recommended humidifiers: Invacare 3260, 003-40, 006-40, or M5120). Replace the humidifier cap and securely tighten. PLUG IN POWER CORD 1.
...IF SO PRESCRIBED) 1. Place the humidifier in power cord to an electrical outlet. Fill humidifier with distilled water to assure sufficient air flow. OPERATING INSTRUCTIONS NOTE: Ensure that your concentrator is at least 7.5 cm (3 in) away from the humidifier bottle WILL travel through the cannula back to the ...patient. Water from walls, draperies or furniture to the level indicated by the manufacturer. (Recommended humidifiers: Invacare 3260, 003-40, 006-40, or M5120). Replace the humidifier cap and securely tighten. PLUG IN POWER CORD 1.
Owners Manual
Page 15
... HUMIDIFIER BOTTLE ADAPTER 15 Remove the Filter Access Door located on the top edge of the concentrator. Attach it is securely fastened (FIGURE 4, DETAIL "C"). OPERATING INSTRUCTIONS 3.
... HUMIDIFIER BOTTLE ADAPTER 15 Remove the Filter Access Door located on the top edge of the concentrator. Attach it is securely fastened (FIGURE 4, DETAIL "C"). OPERATING INSTRUCTIONS 3.
Owners Manual
Page 16
...Replace the filter access door on for one second, indicating that the unit is flowing through the cannula. 9. On/Off (I/O) Power Switch FLOWRATE FIGURE 6 - POWER SWITCH 1. OPERATING INSTRUCTIONS 6. After assembly, ensure that the concentrator be operated a minimum of 30 minutes during any use. Press power switch to the setting... prescribed by snapping it back into the plate groove. WARNING For optimum performance, Invacare ...
...Replace the filter access door on for one second, indicating that the unit is flowing through the cannula. 9. On/Off (I/O) Power Switch FLOWRATE FIGURE 6 - POWER SWITCH 1. OPERATING INSTRUCTIONS 6. After assembly, ensure that the concentrator be operated a minimum of 30 minutes during any use. Press power switch to the setting... prescribed by snapping it back into the plate groove. WARNING For optimum performance, Invacare ...
Owners Manual
Page 17
...knob until the ball rises to reach maximum. for more than 85%). ADJUSTING THE FLOWRATEPLATINUM 5 WITH SENSO2 SHOWN NOTE: The use of the audible alarm. OPERATING INSTRUCTIONS WARNING DO NOT change has been prescribed by the oxygen concentrator. Now, center the ball on the flowmeter ever falls below ... are as the Homefill compressor will come on (SYSTEM OK/O2 greater than 0.5 L/min., the Low Flow audible alarm will be triggered. setting on oxygen concentration values. After rated flow is restored, more than about one minute, the LOW FLOW ALARM will go off. If purity ...
...knob until the ball rises to reach maximum. for more than 85%). ADJUSTING THE FLOWRATEPLATINUM 5 WITH SENSO2 SHOWN NOTE: The use of the audible alarm. OPERATING INSTRUCTIONS WARNING DO NOT change has been prescribed by the oxygen concentrator. Now, center the ball on the flowmeter ever falls below ... are as the Homefill compressor will come on (SYSTEM OK/O2 greater than 0.5 L/min., the Low Flow audible alarm will be triggered. setting on oxygen concentration values. After rated flow is restored, more than about one minute, the LOW FLOW ALARM will go off. If purity ...
Owners Manual
Page 18
... certain that BACKUP OXYGEN is nearby. GREEN LIGHT - you may continue to use the concentrator unless instructed otherwise by your supplier. Down Use Backup RED Call Supplier Below Normal YELLOW Normal O2 GREEN FIGURE 8 - GREEN... LIGHT (I /O GREEN FIGURE 9 - DISPLAY CONTROL PANEL 18 Switch IMMEDIATELY to BACKUP OXYGEN supply. System okay. RED LIGHT ( )- Call Supplier IMMEDIATELY. IF YOUR UNIT DOES NOT FEATURE THE O2 SENSOR LX MODELS...
... certain that BACKUP OXYGEN is nearby. GREEN LIGHT - you may continue to use the concentrator unless instructed otherwise by your supplier. Down Use Backup RED Call Supplier Below Normal YELLOW Normal O2 GREEN FIGURE 8 - GREEN... LIGHT (I /O GREEN FIGURE 9 - DISPLAY CONTROL PANEL 18 Switch IMMEDIATELY to BACKUP OXYGEN supply. System okay. RED LIGHT ( )- Call Supplier IMMEDIATELY. IF YOUR UNIT DOES NOT FEATURE THE O2 SENSOR LX MODELS...
Owners Manual
Page 19
...(FIGURE 2). In places with a vacuum cleaner or wash in service to be performed more frequent cleaning of the filters include but ... of the cabinet (FIGURE 1). 1. CLEANING THE CABINET FILTERS NOTE: There are specifically designed to : high dust, smoking, air pollutants, etc. FIGURE 1 - ...may need to be performed by the user or caregiver. Dry the filters thoroughly before beginning preventive maintenance on the Invacare concentrator. FIGURE 2 - The following.... CLEANING THE CABINET FILTERS 19 NOTE: The Invacare Concentrators are two (2) cabinet filters. Power should...
...(FIGURE 2). In places with a vacuum cleaner or wash in service to be performed more frequent cleaning of the filters include but ... of the cabinet (FIGURE 1). 1. CLEANING THE CABINET FILTERS NOTE: There are specifically designed to : high dust, smoking, air pollutants, etc. FIGURE 1 - ...may need to be performed by the user or caregiver. Dry the filters thoroughly before beginning preventive maintenance on the Invacare concentrator. FIGURE 2 - The following.... CLEANING THE CABINET FILTERS 19 NOTE: The Invacare Concentrators are two (2) cabinet filters. Power should...
Owners Manual
Page 20
...the oxygen humidifier, follow these steps: 1. If none are provided, follow the instructions provided by the manufacturer. CONCENTRATOR TROUBLESHOOTING GUIDE SYMPTOM: PROBABLE CAUSE: SOLUTION: Alarm: SHORT BEEPS, LONG PAUSE Concentrator NOT operating,...repairs required. 3. To avoid electrical shock, DO NOT remove cabinet. 1. Clean the humidifier every day. 2. Main Power Loss: 1. System Failure: 1. Unit overheating due to another electrical outlet or circuit. 3. Do not use a different outlet. 3. Move to blocked air intake. 1a. MAINTENANCE/TROUBLESHOOTING B. Call Service...
...the oxygen humidifier, follow these steps: 1. If none are provided, follow the instructions provided by the manufacturer. CONCENTRATOR TROUBLESHOOTING GUIDE SYMPTOM: PROBABLE CAUSE: SOLUTION: Alarm: SHORT BEEPS, LONG PAUSE Concentrator NOT operating,...repairs required. 3. To avoid electrical shock, DO NOT remove cabinet. 1. Clean the humidifier every day. 2. Main Power Loss: 1. System Failure: 1. Unit overheating due to another electrical outlet or circuit. 3. Do not use a different outlet. 3. Move to blocked air intake. 1a. MAINTENANCE/TROUBLESHOOTING B. Call Service...
Owners Manual
Page 21
...Correct, clean or replace item. Check flowmeter is set at least 7.5 cm (3 in the Operating Instructions of this manual. 4a. Call Service Provider. or less. 1a. Reset flowmeter to SensO2 models. TROUBLESHOOTING SYMPTOM: YELLOW or RED LIGHT Illuminated. Flowmeter set to Recommended End-User Guidelines in )....* 3. Internal repairs required. Alarm: RAPID Beep....Beep... Correct, clean or replace item. LOW FLOW ALARM 1a. Refer to 1.0 L/min. Do not use extension cords. Inspect for kinks or blockages. PROBABLE CAUSE: 1. Clean or replace filters. 2. ...
...Correct, clean or replace item. Check flowmeter is set at least 7.5 cm (3 in the Operating Instructions of this manual. 4a. Call Service Provider. or less. 1a. Reset flowmeter to SensO2 models. TROUBLESHOOTING SYMPTOM: YELLOW or RED LIGHT Illuminated. Flowmeter set to Recommended End-User Guidelines in )....* 3. Internal repairs required. Alarm: RAPID Beep....Beep... Correct, clean or replace item. LOW FLOW ALARM 1a. Refer to 1.0 L/min. Do not use extension cords. Inspect for kinks or blockages. PROBABLE CAUSE: 1. Clean or replace filters. 2. ...
Owners Manual
Page 22
... Alarm AS REQUIRED Clean Heat Exchanger Replace Exhaust Muffler Rebuild Top End of Compressor *Refer to Preventive Maintenance section of Service Record Elapsed Hours On Hour Meter Clean Cabinet Filter(s) Check Prescribed L/min. PREVENTIVE MAINTENANCE RECORD MODEL NO.IRC SERIAL NO 22 PREVENTIVE MAINTENANCE RECORD INVACARE PLATINUM OXYGEN CONCENTRATOR ON EACH INSPECTION Record Date of Service Manual.
... Alarm AS REQUIRED Clean Heat Exchanger Replace Exhaust Muffler Rebuild Top End of Compressor *Refer to Preventive Maintenance section of Service Record Elapsed Hours On Hour Meter Clean Cabinet Filter(s) Check Prescribed L/min. PREVENTIVE MAINTENANCE RECORD MODEL NO.IRC SERIAL NO 22 PREVENTIVE MAINTENANCE RECORD INVACARE PLATINUM OXYGEN CONCENTRATOR ON EACH INSPECTION Record Date of Service Manual.
Owners Manual
Page 23
... Oxygen Concentrators IRC5LXAW and IRC5LXO2AW to be returned to either Invacare's plant or service center as specified by Invacare. The 4-way valve body carries a lifetime warranty from date of purchase. Invacare's sole obligation, and your exclusive remedy under this warranty being limited to such repair or replacement. Defective component part(s) must be repaired or replaced, at Invacare's option; LIMITATIONS AND EXCLUSIONS...
... Oxygen Concentrators IRC5LXAW and IRC5LXO2AW to be returned to either Invacare's plant or service center as specified by Invacare. The 4-way valve body carries a lifetime warranty from date of purchase. Invacare's sole obligation, and your exclusive remedy under this warranty being limited to such repair or replacement. Defective component part(s) must be repaired or replaced, at Invacare's option; LIMITATIONS AND EXCLUSIONS...
Owners Manual
Page 148
Sanford, Florida 32773 Technical Support: Toll Free 800-832-4707 www.invacare.com All rights reserved. Trademarks are owned by the symbols ™and ®. All trademarks are identified by or licensed to Invacare Corporation or its subsidiaries unless otherwise noted. © 2009 Invacare Corporation Part No. 1118389 Rev C - 04/09 Lake Mary Blvd. Invacare Corporation USA One Invacare Way Elyria, Ohio USA 44036-2125 800-333-6900 2101 E.
Sanford, Florida 32773 Technical Support: Toll Free 800-832-4707 www.invacare.com All rights reserved. Trademarks are owned by the symbols ™and ®. All trademarks are identified by or licensed to Invacare Corporation or its subsidiaries unless otherwise noted. © 2009 Invacare Corporation Part No. 1118389 Rev C - 04/09 Lake Mary Blvd. Invacare Corporation USA One Invacare Way Elyria, Ohio USA 44036-2125 800-333-6900 2101 E.