Page 3
...21 Performing an Emergency Stop 22 Charging the Battery 23 7 LIFTING THE PATIENT 24 Introduction 24 Positioning the Patient Lift 24 Attaching a Sling 25 Lifting/Moving the Patient 26 Part No. 1145810 3 Electric Portable Patient Lift USER: BEFORE using this product, read this manual and save for future reference. 1 GENERAL ... Lift 13 Full Body, Divided Leg and Toileting Slings 14 Reliant Scale RLS6 14 5 ASSEMBLY 15 Introduction 15 Unpacking the Patient Lift 15 Assembling the Mast to the Base 16 Assembling the Boom Actuator 17 Installing the Leg Actuator to the user ...
...21 Performing an Emergency Stop 22 Charging the Battery 23 7 LIFTING THE PATIENT 24 Introduction 24 Positioning the Patient Lift 24 Attaching a Sling 25 Lifting/Moving the Patient 26 Part No. 1145810 3 Electric Portable Patient Lift USER: BEFORE using this product, read this manual and save for future reference. 1 GENERAL ... Lift 13 Full Body, Divided Leg and Toileting Slings 14 Reliant Scale RLS6 14 5 ASSEMBLY 15 Introduction 15 Unpacking the Patient Lift 15 Assembling the Mast to the Base 16 Assembling the Boom Actuator 17 Installing the Leg Actuator to the user ...
Owners Manual
Page 6
... of our products. For warranty service, please contact the dealer from state to such repair and/or replacement. THE WARRANTY SHALL NOT APPLY TO PROBLEMS ARISING FROM NORMAL WEAR OR FAILURE TO ADHERE TO THE INSTRUCTIONS IN THIS MANUAL. IMPLIED WARRANTIES, IF ANY, ...be repaired or replaced, at the address on the slings and electric components from defects in replacement part installation or repair of purchase. PRODUCTS DAMAGED BY REASON OF REPAIRS MADE TO ANY COMPONENT WITHOUT THE SPECIFIC CONSENT OF INVACARE, OR TO A PRODUCT DAMAGED BY CIRCUMSTANCES BEYOND INVACARE'S ...
... of our products. For warranty service, please contact the dealer from state to such repair and/or replacement. THE WARRANTY SHALL NOT APPLY TO PROBLEMS ARISING FROM NORMAL WEAR OR FAILURE TO ADHERE TO THE INSTRUCTIONS IN THIS MANUAL. IMPLIED WARRANTIES, IF ANY, ...be repaired or replaced, at the address on the slings and electric components from defects in replacement part installation or repair of purchase. PRODUCTS DAMAGED BY REASON OF REPAIRS MADE TO ANY COMPONENT WITHOUT THE SPECIFIC CONSENT OF INVACARE, OR TO A PRODUCT DAMAGED BY CIRCUMSTANCES BEYOND INVACARE'S ...
Owners Manual
Page 7
... a bed to be used in conjunction with Invacare accessories. Otherwise injury or damage may occur. Use common sense in this Owner's Manual, observe a trained team of experts perform the lifting procedures and then perform the entire lift procedure several times with proper supervision and a capable individual acting as owner's manuals, service manuals or instruction sheets supplied with Invacare patient lifts. Slings and accessories designed...
... a bed to be used in conjunction with Invacare accessories. Otherwise injury or damage may occur. Use common sense in this Owner's Manual, observe a trained team of experts perform the lifting procedures and then perform the entire lift procedure several times with proper supervision and a capable individual acting as owner's manuals, service manuals or instruction sheets supplied with Invacare patient lifts. Slings and accessories designed...
Owners Manual
Page 8
... by one assistant is based on the battery charger to avoid injury. Operating the Lift ƽ WARNING Although Invacare recommends that two assistants be aware of the position of moving parts to confirm proper mounting. The weight limitation for each individual case. When positioning lift, be used for the RPL450-2 is 600 lbs. ALWAYS keep hands and...
... by one assistant is based on the battery charger to avoid injury. Operating the Lift ƽ WARNING Although Invacare recommends that two assistants be aware of the position of moving parts to confirm proper mounting. The weight limitation for each individual case. When positioning lift, be used for the RPL450-2 is 600 lbs. ALWAYS keep hands and...
Owners Manual
Page 9
...problem. Adjustments for patient's back. Warranty will leave little or no support for safety and comfort should be inside of the straps MUST be made specifically for support. Invacare does not recommend locking of the rear casters of different manufacturers. DO NOT use with color coded straps to the patient lift...Part No. 1145810 9 Electric Portable Patient Lift After each time the sling is removed and replaced, to ensure that it easy to push or pull the patient lift... being lifted. During transfer, with instructions on the mast at the back of patient for use any kind...
...problem. Adjustments for patient's back. Warranty will leave little or no support for safety and comfort should be inside of the straps MUST be made specifically for support. Invacare does not recommend locking of the rear casters of different manufacturers. DO NOT use with color coded straps to the patient lift...Part No. 1145810 9 Electric Portable Patient Lift After each time the sling is removed and replaced, to ensure that it easy to push or pull the patient lift... being lifted. During transfer, with instructions on the mast at the back of patient for use any kind...
Owners Manual
Page 11
Carefully read battery/battery charger information prior to the use ONLY a three-wire extension cord having the same or higher electrical rating as the device being connected. DO NOT dispose of batteries in the area around such equipment. They MUST be exercised with regard to installing, servicing or operating your local waste management company for Invacare products. Where...
Carefully read battery/battery charger information prior to the use ONLY a three-wire extension cord having the same or higher electrical rating as the device being connected. DO NOT dispose of batteries in the area around such equipment. They MUST be exercised with regard to installing, servicing or operating your local waste management company for Invacare products. Where...
Owners Manual
Page 12
... this patient lift model. WEIGHT LIMITATION 600 lbs. DO NOT roll casterbase over uneven surfaces that may cause the Patient Lift to stabilize during lifting procedures. 3 PRODUCT LABELING 3 Product Labeling BEFORE using the Patient Lift, READ and UNDERSTAND the Owner's Manual for proper operation and safety procedures. Customer Service 1-800-333-6900 1070965 Rev B Electric Portable Patient Lift 12 Part No...
... this patient lift model. WEIGHT LIMITATION 600 lbs. DO NOT roll casterbase over uneven surfaces that may cause the Patient Lift to stabilize during lifting procedures. 3 PRODUCT LABELING 3 Product Labeling BEFORE using the Patient Lift, READ and UNDERSTAND the Owner's Manual for proper operation and safety procedures. Customer Service 1-800-333-6900 1070965 Rev B Electric Portable Patient Lift 12 Part No...
Owners Manual
Page 13
... Style 600 lbs 141 lbs 115 lbs 13 Electric Portable Patient Lift MIN.: Base Width OPEN: Base Width CLOSED: Base Height (Clearance...of Carton: Battery: Charger Input: Charger Output/Charging Time: Accessories: Audio Low Battery Alarm: Motor Safety Devices: Approx. ELECTRIC LOW PROFILE RPL450-2 74 ...inches 24 inches 3 Styles 450 lbs 136 lbs 109 lbs 41.0 inches 26.5 inches 4.5 inches 48.0 inches 3.0/5.0 inches 24V DC (RCHBL) 100-240V AC 29.5V DC Max 6 hrs Digital Scale Yes Anti-Entrapment 100-200 Cycles per Charge (Varies depending upon load and stroke): Warranty Electronics: Part...
... Style 600 lbs 141 lbs 115 lbs 13 Electric Portable Patient Lift MIN.: Base Width OPEN: Base Width CLOSED: Base Height (Clearance...of Carton: Battery: Charger Input: Charger Output/Charging Time: Accessories: Audio Low Battery Alarm: Motor Safety Devices: Approx. ELECTRIC LOW PROFILE RPL450-2 74 ...inches 24 inches 3 Styles 450 lbs 136 lbs 109 lbs 41.0 inches 26.5 inches 4.5 inches 48.0 inches 3.0/5.0 inches 24V DC (RCHBL) 100-240V AC 29.5V DC Max 6 hrs Digital Scale Yes Anti-Entrapment 100-200 Cycles per Charge (Varies depending upon load and stroke): Warranty Electronics: Part...
Owners Manual
Page 19
...wall electrical outlet. 9. Tighten securely. 8. Measure down 6½ inches from the pencil mark and drill one mounting hole. 4. Install the battery charger with mounting bracket on the wall at the desired position. 2. Drill the remaining two mounting holes. 7. Verify that ON is... an approximate 1/8-inch gap between the screw head and the wall. 5. 5.6 Mounting the Battery Charger Refer to your local regulations concerning proper mounting procedures. 1. Place the battery charger with mounting bracket onto the bottom mounting screw. 6. With a pencil, mark the middle ...
...wall electrical outlet. 9. Tighten securely. 8. Measure down 6½ inches from the pencil mark and drill one mounting hole. 4. Install the battery charger with mounting bracket on the wall at the desired position. 2. Drill the remaining two mounting holes. 7. Verify that ON is... an approximate 1/8-inch gap between the screw head and the wall. 5. 5.6 Mounting the Battery Charger Refer to your local regulations concerning proper mounting procedures. 1. Place the battery charger with mounting bracket onto the bottom mounting screw. 6. With a pencil, mark the middle ...
Owners Manual
Page 20
...instructions in the maximum open position. Invacare recommends that two assistants be used to raise/lower the boom or to raise the boom and the patient. If it takes to /from procedures; When the legs of the lift are no longer under a bed, close the legs of the lift... the legs closed button. Boom Up Button Legs Open Button Boom Down Button Legs Closed Button Electric Portable Patient Lift 20 Part No. 1145810 however, the patient lift can be in this Owner's Manual, observe a trained team of the bed. The pendant is based on the evaluation of the patient...
...instructions in the maximum open position. Invacare recommends that two assistants be used to raise/lower the boom or to raise the boom and the patient. If it takes to /from procedures; When the legs of the lift are no longer under a bed, close the legs of the lift... the legs closed button. Boom Up Button Legs Open Button Boom Down Button Legs Closed Button Electric Portable Patient Lift 20 Part No. 1145810 however, the patient lift can be in this Owner's Manual, observe a trained team of the bed. The pendant is based on the evaluation of the patient...
Owners Manual
Page 23
... is low. 1. When charging is an audible click when mounting battery on the battery charger to prolong battery life. Otherwise, injury or damage may occur. 3. 6.5 Charging the Battery Invacare recommends the battery be fully recharged will take approximately four hours. 4. Part No. 1145810 23 Electric Portable Patient Lift An audible alarm will sound (horn will beep) when...
... is low. 1. When charging is an audible click when mounting battery on the battery charger to prolong battery life. Otherwise, injury or damage may occur. 3. 6.5 Charging the Battery Invacare recommends the battery be fully recharged will take approximately four hours. 4. Part No. 1145810 23 Electric Portable Patient Lift An audible alarm will sound (horn will beep) when...
Owners Manual
Page 25
... Part No. 1145810 Color Coded Straps 25 Color Coded Straps Electric Portable Patient Lift 7.3 Attaching a Sling 1. DETAIL "A" - R117 Full Body Slings and Model No. R121 Toileting Sling have three hookup points per side. 3. Invacare Lift Swivel Bars have four sling straps. R102 Divided Leg Slings have three sets of the sling for slings that have six sling straps. Use...
... Part No. 1145810 Color Coded Straps 25 Color Coded Straps Electric Portable Patient Lift 7.3 Attaching a Sling 1. DETAIL "A" - R117 Full Body Slings and Model No. R121 Toileting Sling have three hookup points per side. 3. Invacare Lift Swivel Bars have four sling straps. R102 Divided Leg Slings have three sets of the sling for slings that have six sling straps. Use...
Owners Manual
Page 26
...made specifically for safety and comfort should be made before moving the patient, check again to a sitting position (Detail "A" of the swivel bar. Injury or damage may occur. For this problem ...connected to the hooks of FIGURE 7.1 on page 27. Electric Portable Patient Lift 26 Part No. 1145810 Invacare slings are NOT properly in position until his legs straddle the mast and his...7.1 on page 27). 4. DO NOT use with the patient's head supported by the sling and/or an assistant), he /she will be fully supported by the patient lift. The boom will be raised...
...made specifically for safety and comfort should be made before moving the patient, check again to a sitting position (Detail "A" of the swivel bar. Injury or damage may occur. For this problem ...connected to the hooks of FIGURE 7.1 on page 27. Electric Portable Patient Lift 26 Part No. 1145810 Invacare slings are NOT properly in position until his legs straddle the mast and his...7.1 on page 27). 4. DO NOT use with the patient's head supported by the sling and/or an assistant), he /she will be fully supported by the patient lift. The boom will be raised...
Owners Manual
Page 30
... instructions and use them in Lifting the Patient on page 31. 1. Refer to Lifting ...supported by the patient lift. 5. Use an empty patient lift to check if the patient lift can maneuver around the commode. 2. If the patient lift can maneuver around the commode, lift...lift. 7. Detach the sling from the bed. Bathe the patient. 9. 8 TRANSFERRING THE PATIENT 8.3 Transferring to a Standard Commode The Invacare patient lift...using the steering handle), move the lift away from the bed. Reverse this Owner's Manual. 1. Electric Portable Patient Lift 30 Part No. 1145810
... instructions and use them in Lifting the Patient on page 31. 1. Refer to Lifting ...supported by the patient lift. 5. Use an empty patient lift to check if the patient lift can maneuver around the commode. 2. If the patient lift can maneuver around the commode, lift...lift. 7. Detach the sling from the bed. Bathe the patient. 9. 8 TRANSFERRING THE PATIENT 8.3 Transferring to a Standard Commode The Invacare patient lift...using the steering handle), move the lift away from the bed. Reverse this Owner's Manual. 1. Electric Portable Patient Lift 30 Part No. 1145810
Owners Manual
Page 31
... unless a divided leg sling was used. Remove a divided leg sling. 10. Ensure the legs of the lift with their back against the back of the wheelchair. Use the straps or handles on page ... return to guide the patient's hips as far back as possible into the wheelchair for this step - The assistant behind the chair and the other operates the patient lift. Press the... Lifting the Patient on select models) or sides of the sling to prevent movement of balance and prevent the chair from the bed. Part No. 1145810 31 8 TRANSFERRING THE PATIENT Electric Portable Patient Lift ...
... unless a divided leg sling was used. Remove a divided leg sling. 10. Ensure the legs of the lift with their back against the back of the wheelchair. Use the straps or handles on page ... return to guide the patient's hips as far back as possible into the wheelchair for this step - The assistant behind the chair and the other operates the patient lift. Press the... Lifting the Patient on select models) or sides of the sling to prevent movement of balance and prevent the chair from the bed. Part No. 1145810 31 8 TRANSFERRING THE PATIENT Electric Portable Patient Lift ...
Owners Manual
Page 35
All parts of the Patient Lift are made of the best grades of steel, but metal to provide a maximum of the problem. 10.2 Lubricating the Lift The Invacare lift is designed for tightness. Lubricate the following points: 1. Boom/Mast Mount 4. 10 MAINTENANCE The Invacare Patient Lift is designed to metal contact will wear after considerable use. Any defect should ensure...
All parts of the Patient Lift are made of the best grades of steel, but metal to provide a maximum of the problem. 10.2 Lubricating the Lift The Invacare lift is designed for tightness. Lubricate the following points: 1. Boom/Mast Mount 4. 10 MAINTENANCE The Invacare Patient Lift is designed to metal contact will wear after considerable use. Any defect should ensure...
Owners Manual
Page 36
The lift can be cleaned with water and a small amount of cracking, fraying, deformation or deterioration. Remove the boom actuator assembly. 4. Replace any pivot for slings for installation. This damages the mounting bracket. A soft cloth, dampened with non-abrasive cleaners. 10.5 Replacing the Boom Actuator...steps for signs of mild detergent, is all stressed parts, such as slings, spreader bar and any defective parts immediately and ensure that is not used until repairs are made. 10.4 Cleaning the Sling and the Lift The sling should be regularly washed in water, temperature...
The lift can be cleaned with water and a small amount of cracking, fraying, deformation or deterioration. Remove the boom actuator assembly. 4. Replace any pivot for slings for installation. This damages the mounting bracket. A soft cloth, dampened with non-abrasive cleaners. 10.5 Replacing the Boom Actuator...steps for signs of mild detergent, is all stressed parts, such as slings, spreader bar and any defective parts immediately and ensure that is not used until repairs are made. 10.4 Cleaning the Sling and the Lift The sling should be regularly washed in water, temperature...
Owners Manual
Page 46
...shown in the display window to notify when battery is to change the unit of measurement from pounds (lb) to kilograms (kg). Attach sling. 2. Lift patient. 5. The function of this key is...ON ZERO LOCK WEIGHT Electric Portable Patient Lift 46 Part No. 1145810 Display Window Operation Keys lb kg ZERO LOCK ON OFF ZERO UNITS LOCK UNLOCK Reliant Scale Model RLS6 CAPACITY 600 LB, 272 KG ... STORED weight and not the current weight when the key is used in the display window. Press ON key. 3. Lower Patient 7. This key is used to lock or unlock a weight value in the lock position....
...shown in the display window to notify when battery is to change the unit of measurement from pounds (lb) to kilograms (kg). Attach sling. 2. Lift patient. 5. The function of this key is...ON ZERO LOCK WEIGHT Electric Portable Patient Lift 46 Part No. 1145810 Display Window Operation Keys lb kg ZERO LOCK ON OFF ZERO UNITS LOCK UNLOCK Reliant Scale Model RLS6 CAPACITY 600 LB, 272 KG ... STORED weight and not the current weight when the key is used in the display window. Press ON key. 3. Lower Patient 7. This key is used to lock or unlock a weight value in the lock position....
Owners Manual
Page 47
...USER'S TRUE WEIGHT. 3. The lock function will then be indicated by the lift. Place the patient in order to avoid capturing the weight of the sling and the hardware. Activate the lift mechanism to raise the patient until they are completely supported... by the word "LOCK" appearing in the display. When the weight display becomes stable press the LOCK button to the swivel bar. Part No. 1145810 47 Electric Portable Patient Lift For proper attachment instructions refer to Attaching a Sling on page 25. For improved accuracy on the 450 and 600 Reliant lifts... updating ...
...USER'S TRUE WEIGHT. 3. The lock function will then be indicated by the lift. Place the patient in order to avoid capturing the weight of the sling and the hardware. Activate the lift mechanism to raise the patient until they are completely supported... by the word "LOCK" appearing in the display. When the weight display becomes stable press the LOCK button to the swivel bar. Part No. 1145810 47 Electric Portable Patient Lift For proper attachment instructions refer to Attaching a Sling on page 25. For improved accuracy on the 450 and 600 Reliant lifts... updating ...